Add RAID to example hardwareprofile
This adds supported RAID levels and their associated parameters in the example hardwareprofile. This is an extension to the hardwareprofile that was created by a previous patch. https://review.opendev.org/#/c/740132/ Since there is no default RAID profile, the template does not have a RAID field in it, only the VariableCatalogue is updated. Change-Id: I50c82ce5f8f66aad132571e631f231623704862a Closes: #337
This commit is contained in:
parent
a5b003a347
commit
58c8284f74
@ -2,12 +2,24 @@ Function: hardwareprofile-example
|
||||
=================================
|
||||
|
||||
This function defines a hardware profile that can be consumed by the
|
||||
hostgenerator-m3 function, and which has the same values as the default
|
||||
profile defined in that function. It serves as an example for how other
|
||||
hostgenerator-m3 function. It serves as an example for how other
|
||||
hardware profile functions can be created and consumed.
|
||||
|
||||
The `/replacements` kustomization contains a substution rule that injects
|
||||
The `example` profile currently has fields for RAID and firmware configurations.
|
||||
This is to provide as a reference for utilizing all the supported RAID levels
|
||||
as well as all the supported firmware configurations.
|
||||
|
||||
For firmware configurations, the values from `example` profile are carried over
|
||||
to the `default` profile of hostgenerator-m3. That is because same defaults
|
||||
are exercised in metal3 baremetal-operator as well. See [bios-config spec]
|
||||
However, for RAID configurations, since
|
||||
there is no `default` profile, the template does *__not__* have any RAID fields.
|
||||
Nevertheless, all the supported RAID configurations
|
||||
have been listed in the `hardwareprofile.yaml` for your reference.
|
||||
|
||||
The `/replacements` kustomization contains a substitution rule that injects
|
||||
the profile into the hostgenerator BMH template. Please see the
|
||||
`manifests/type/gating` type and `manifests/type/test-site`
|
||||
`manifests/type/gating` type and `manifests/site/test-site` site
|
||||
kustomization.yamls to see how a hardwareprofile function can be wired in.
|
||||
|
||||
[bios-config spec]: https://github.com/metal3-io/metal3-docs/blob/master/design/baremetal-operator/bios-config.md
|
||||
|
@ -8,3 +8,25 @@ hardwareProfile:
|
||||
sriovEnabled: false
|
||||
virtualizationDisabled: false
|
||||
simultaneousMultithreadingDisabled: false
|
||||
raid:
|
||||
hardwareRAIDVolumes:
|
||||
- name: "VirtualDisk1"
|
||||
level: "1+0"
|
||||
sizeGibibytes: 1024
|
||||
numberOfPhysicalDisks: 4
|
||||
rotational: False
|
||||
- name: "VirtualDisk2"
|
||||
level: "1"
|
||||
sizeGibibytes: 500
|
||||
numberOfPhysicalDisks: 2
|
||||
rotational: True
|
||||
- name: "VirtualDisk3"
|
||||
level: "0"
|
||||
sizeGibibytes: 500
|
||||
numberOfPhysicalDisks: 2
|
||||
rotational: True
|
||||
- name: "VirtualDisk4"
|
||||
level: "0"
|
||||
sizeGibibytes: 250
|
||||
numberOfPhysicalDisks: 1
|
||||
rotational: False
|
@ -47,6 +47,12 @@ template: |
|
||||
credentialsName: {{ $hostName }}-bmc-secret
|
||||
firmware:
|
||||
{{ toYaml $hardwareProfile.firmware | indent 4 }}
|
||||
{{- /* If no raid is defined for a host, simply skip. There is no default setting for raid */ -}}
|
||||
{{- /* Reference for RAID: https://github.com/metal3-io/metal3-docs/pull/134 */ -}}
|
||||
{{- if $hardwareProfile.raid }}
|
||||
raid:
|
||||
{{ toYaml $hardwareProfile.raid | indent 4 }}
|
||||
{{- end }}
|
||||
|
||||
---
|
||||