aodh/ceilometer/compute/pollsters.py
Yunhong, Jiang 0425a42bfd Update pollsters to return counter list
Have pollsters to return the counter list that will be potentially returned.

For bp publisher-counters-frequency

Change-Id: I103f8ed6ad314080d479d4a2053e0df4312c60a3
Signed-off-by: Yunhong, Jiang <yunhong.jiang@intel.com>
2013-02-05 09:10:19 +08:00

273 lines
12 KiB
Python

# -*- encoding: utf-8 -*-
#
# Copyright © 2012 eNovance <licensing@enovance.com>
# Copyright © 2012 Red Hat, Inc
#
# Author: Julien Danjou <julien@danjou.info>
# Author: Eoghan Glynn <eglynn@redhat.com>
#
# Licensed under the Apache License, Version 2.0 (the "License"); you may
# not use this file except in compliance with the License. You may obtain
# a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS, WITHOUT
# WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the
# License for the specific language governing permissions and limitations
# under the License.
import copy
import datetime
from ceilometer import counter
from ceilometer.compute import plugin
from ceilometer.compute import instance as compute_instance
from ceilometer.openstack.common import log
from ceilometer.openstack.common import timeutils
LOG = log.getLogger(__name__)
def _instance_name(instance):
"""Shortcut to get instance name"""
return getattr(instance, 'OS-EXT-SRV-ATTR:instance_name', None)
def make_counter_from_instance(instance, name, type, unit, volume):
return counter.Counter(
name=name,
type=type,
unit=unit,
volume=volume,
user_id=instance.user_id,
project_id=instance.tenant_id,
resource_id=instance.id,
timestamp=timeutils.isotime(),
resource_metadata=compute_instance.get_metadata_from_object(instance),
)
class InstancePollster(plugin.ComputePollster):
@staticmethod
def get_counter_names():
# Instance type counter is specific because it includes
# variable. We don't need such format in future
return ['instance', 'instance:*']
def get_counters(self, manager, instance):
yield make_counter_from_instance(instance,
name='instance',
type=counter.TYPE_GAUGE,
unit='instance',
volume=1)
yield make_counter_from_instance(instance,
name='instance:%s' %
instance.flavor['name'],
type=counter.TYPE_GAUGE,
unit='instance',
volume=1)
class DiskIOPollster(plugin.ComputePollster):
LOG = log.getLogger(__name__ + '.diskio')
DISKIO_USAGE_MESSAGE = ' '.join(["DISKIO USAGE:",
"%s %s:",
"read-requests=%d",
"read-bytes=%d",
"write-requests=%d",
"write-bytes=%d",
"errors=%d",
])
@staticmethod
def get_counter_names():
return ['disk.read.requests',
'disk.read.bytes',
'disk.write.requests',
'disk.write.bytes']
def get_counters(self, manager, instance):
instance_name = _instance_name(instance)
try:
r_bytes = 0
r_requests = 0
w_bytes = 0
w_requests = 0
for disk, info in manager.inspector.inspect_disks(instance_name):
self.LOG.info(self.DISKIO_USAGE_MESSAGE,
instance, disk.device, info.read_requests,
info.read_bytes, info.write_requests,
info.write_bytes, info.errors)
r_bytes += info.read_bytes
r_requests += info.read_requests
w_bytes += info.write_bytes
w_requests += info.write_requests
yield make_counter_from_instance(instance,
name='disk.read.requests',
type=counter.TYPE_CUMULATIVE,
unit='request',
volume=r_requests,
)
yield make_counter_from_instance(instance,
name='disk.read.bytes',
type=counter.TYPE_CUMULATIVE,
unit='B',
volume=r_bytes,
)
yield make_counter_from_instance(instance,
name='disk.write.requests',
type=counter.TYPE_CUMULATIVE,
unit='request',
volume=w_requests,
)
yield make_counter_from_instance(instance,
name='disk.write.bytes',
type=counter.TYPE_CUMULATIVE,
unit='B',
volume=w_bytes,
)
except Exception as err:
self.LOG.warning('Ignoring instance %s: %s',
instance_name, err)
self.LOG.exception(err)
class CPUPollster(plugin.ComputePollster):
LOG = log.getLogger(__name__ + '.cpu')
utilization_map = {}
def get_cpu_util(self, instance, cpu_info):
prev_times = self.utilization_map.get(instance.id)
self.utilization_map[instance.id] = (cpu_info.time,
datetime.datetime.now())
cpu_util = 0.0
if prev_times:
prev_cpu = prev_times[0]
prev_timestamp = prev_times[1]
delta = self.utilization_map[instance.id][1] - prev_timestamp
elapsed = (delta.seconds * (10 ** 6) + delta.microseconds) * 1000
cores_fraction = 1.0 / cpu_info.number
# account for cpu_time being reset when the instance is restarted
time_used = (cpu_info.time - prev_cpu
if prev_cpu <= cpu_info.time else cpu_info.time)
cpu_util = 100 * cores_fraction * time_used / elapsed
return cpu_util
@staticmethod
def get_counter_names():
return ['cpu', 'cpu_util']
def get_counters(self, manager, instance):
self.LOG.info('checking instance %s', instance.id)
instance_name = _instance_name(instance)
try:
cpu_info = manager.inspector.inspect_cpus(instance_name)
self.LOG.info("CPUTIME USAGE: %s %d",
instance.__dict__, cpu_info.time)
cpu_util = self.get_cpu_util(instance, cpu_info)
self.LOG.info("CPU UTILIZATION %%: %s %0.2f",
instance.__dict__, cpu_util)
# FIXME(eglynn): once we have a way of configuring which measures
# are published to each sink, we should by default
# disable publishing this derived measure to the
# metering store, only publishing to those sinks
# that specifically need it
yield make_counter_from_instance(instance,
name='cpu_util',
type=counter.TYPE_GAUGE,
unit='%',
volume=cpu_util,
)
yield make_counter_from_instance(instance,
name='cpu',
type=counter.TYPE_CUMULATIVE,
unit='ns',
volume=cpu_info.time,
)
except Exception as err:
self.LOG.error('could not get CPU time for %s: %s',
instance.id, err)
self.LOG.exception(err)
class NetPollster(plugin.ComputePollster):
LOG = log.getLogger(__name__ + '.net')
NET_USAGE_MESSAGE = ' '.join(["NETWORK USAGE:", "%s %s:", "read-bytes=%d",
"write-bytes=%d"])
@staticmethod
def make_vnic_counter(instance, name, type, unit, volume, vnic_data):
metadata = copy.copy(vnic_data)
resource_metadata = dict(zip(metadata._fields, metadata))
resource_metadata['instance_id'] = instance.id
resource_metadata['instance_type'] = \
instance.flavor['id'] if instance.flavor else None,
return counter.Counter(
name=name,
type=type,
unit=unit,
volume=volume,
user_id=instance.user_id,
project_id=instance.tenant_id,
resource_id=vnic_data.fref,
timestamp=timeutils.isotime(),
resource_metadata=resource_metadata
)
@staticmethod
def get_counter_names():
return ['network.incoming.bytes',
'network.incoming.packets',
'network.outgoing.bytes',
'network.outgoing.packets']
def get_counters(self, manager, instance):
instance_name = _instance_name(instance)
self.LOG.info('checking instance %s', instance.id)
try:
for vnic, info in manager.inspector.inspect_vnics(instance_name):
self.LOG.info(self.NET_USAGE_MESSAGE, instance_name,
vnic.name, info.rx_bytes, info.tx_bytes)
yield self.make_vnic_counter(instance,
name='network.incoming.bytes',
type=counter.TYPE_CUMULATIVE,
unit='B',
volume=info.rx_bytes,
vnic_data=vnic,
)
yield self.make_vnic_counter(instance,
name='network.outgoing.bytes',
type=counter.TYPE_CUMULATIVE,
unit='B',
volume=info.tx_bytes,
vnic_data=vnic,
)
yield self.make_vnic_counter(instance,
name='network.incoming.packets',
type=counter.TYPE_CUMULATIVE,
unit='packet',
volume=info.rx_packets,
vnic_data=vnic,
)
yield self.make_vnic_counter(instance,
name='network.outgoing.packets',
type=counter.TYPE_CUMULATIVE,
unit='packet',
volume=info.tx_packets,
vnic_data=vnic,
)
except Exception as err:
self.LOG.warning('Ignoring instance %s: %s',
instance_name, err)
self.LOG.exception(err)