2d153aa8b4
H307 is a new rule in hacking 0.9, so fix new violations and re-enable gating. Change-Id: I805d10427ebeaee36589936f77a2cf0932c1378e
190 lines
6.0 KiB
Python
190 lines
6.0 KiB
Python
#!/usr/bin/env python
|
|
# -*- coding: utf-8 -*-
|
|
#
|
|
# Copyright 2012-2014 Julien Danjou
|
|
#
|
|
# Author: Julien Danjou <julien@danjou.info>
|
|
#
|
|
# Licensed under the Apache License, Version 2.0 (the "License"); you may
|
|
# not use this file except in compliance with the License. You may obtain
|
|
# a copy of the License at
|
|
#
|
|
# http://www.apache.org/licenses/LICENSE-2.0
|
|
#
|
|
# Unless required by applicable law or agreed to in writing, software
|
|
# distributed under the License is distributed on an "AS IS" BASIS, WITHOUT
|
|
# WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the
|
|
# License for the specific language governing permissions and limitations
|
|
# under the License.
|
|
|
|
"""Command line tool for creating meter for Ceilometer.
|
|
"""
|
|
import logging
|
|
import sys
|
|
|
|
import eventlet
|
|
# NOTE(jd) We need to monkey patch the socket and select module for,
|
|
# at least, oslo.messaging, otherwise everything's blocked on its
|
|
# first read() or select(), thread need to be patched too, because
|
|
# oslo.messaging use threading.local
|
|
eventlet.monkey_patch(socket=True, select=True, thread=True)
|
|
from oslo.config import cfg
|
|
|
|
from ceilometer.alarm import service as alarm_service
|
|
from ceilometer.api import app
|
|
from ceilometer.central import manager as central_manager
|
|
from ceilometer import collector
|
|
from ceilometer.compute import manager as compute_manager
|
|
from ceilometer import notification
|
|
from ceilometer.openstack.common import context
|
|
from ceilometer.openstack.common import importutils
|
|
from ceilometer.openstack.common import service as os_service
|
|
from ceilometer.openstack.common import timeutils
|
|
from ceilometer import pipeline
|
|
from ceilometer import sample
|
|
from ceilometer import service
|
|
from ceilometer import storage
|
|
from ceilometer import transformer
|
|
|
|
|
|
OPTS = [
|
|
cfg.StrOpt('evaluation_service',
|
|
default='ceilometer.alarm.service.SingletonAlarmService',
|
|
help='Class to launch as alarm evaluation service.'),
|
|
]
|
|
|
|
cfg.CONF.register_opts(OPTS, group='alarm')
|
|
cfg.CONF.import_opt('time_to_live', 'ceilometer.storage',
|
|
group='database')
|
|
|
|
LOG = logging.getLogger(__name__)
|
|
|
|
|
|
def alarm_notifier():
|
|
service.prepare_service()
|
|
os_service.launch(alarm_service.AlarmNotifierService()).wait()
|
|
|
|
|
|
def alarm_evaluator():
|
|
service.prepare_service()
|
|
eval_service = importutils.import_object(cfg.CONF.alarm.evaluation_service)
|
|
os_service.launch(eval_service).wait()
|
|
|
|
|
|
def agent_central():
|
|
service.prepare_service()
|
|
os_service.launch(central_manager.AgentManager()).wait()
|
|
|
|
|
|
def agent_compute():
|
|
service.prepare_service()
|
|
os_service.launch(compute_manager.AgentManager()).wait()
|
|
|
|
|
|
def agent_notification():
|
|
service.prepare_service()
|
|
launcher = os_service.ProcessLauncher()
|
|
launcher.launch_service(
|
|
notification.NotificationService(),
|
|
workers=service.get_workers('notification'))
|
|
launcher.wait()
|
|
|
|
|
|
def api():
|
|
service.prepare_service()
|
|
srv = app.build_server()
|
|
srv.serve_forever()
|
|
|
|
|
|
def collector_service():
|
|
service.prepare_service()
|
|
launcher = os_service.ProcessLauncher()
|
|
launcher.launch_service(
|
|
collector.CollectorService(),
|
|
workers=service.get_workers('collector'))
|
|
launcher.wait()
|
|
|
|
|
|
def storage_dbsync():
|
|
service.prepare_service()
|
|
storage.get_connection_from_config(cfg.CONF).upgrade()
|
|
|
|
|
|
def storage_expirer():
|
|
service.prepare_service()
|
|
if cfg.CONF.database.time_to_live > 0:
|
|
LOG.debug(_("Clearing expired metering data"))
|
|
storage_conn = storage.get_connection_from_config(cfg.CONF)
|
|
storage_conn.clear_expired_metering_data(
|
|
cfg.CONF.database.time_to_live)
|
|
else:
|
|
LOG.info(_("Nothing to clean, database time to live is disabled"))
|
|
|
|
|
|
def send_sample():
|
|
cfg.CONF.register_cli_opts([
|
|
cfg.StrOpt('sample-name',
|
|
short='n',
|
|
help='Meter name.',
|
|
required=True),
|
|
cfg.StrOpt('sample-type',
|
|
short='y',
|
|
help='Meter type (gauge, delta, cumulative).',
|
|
default='gauge',
|
|
required=True),
|
|
cfg.StrOpt('sample-unit',
|
|
short='U',
|
|
help='Meter unit.'),
|
|
cfg.IntOpt('sample-volume',
|
|
short='l',
|
|
help='Meter volume value.',
|
|
default=1),
|
|
cfg.StrOpt('sample-resource',
|
|
short='r',
|
|
help='Meter resource id.',
|
|
required=True),
|
|
cfg.StrOpt('sample-user',
|
|
short='u',
|
|
help='Meter user id.'),
|
|
cfg.StrOpt('sample-project',
|
|
short='p',
|
|
help='Meter project id.'),
|
|
cfg.StrOpt('sample-timestamp',
|
|
short='i',
|
|
help='Meter timestamp.',
|
|
default=timeutils.utcnow().isoformat()),
|
|
cfg.StrOpt('sample-metadata',
|
|
short='m',
|
|
help='Meter metadata.'),
|
|
])
|
|
|
|
service.prepare_service()
|
|
|
|
# Set up logging to use the console
|
|
console = logging.StreamHandler(sys.stderr)
|
|
console.setLevel(logging.DEBUG)
|
|
formatter = logging.Formatter('%(message)s')
|
|
console.setFormatter(formatter)
|
|
root_logger = logging.getLogger('')
|
|
root_logger.addHandler(console)
|
|
root_logger.setLevel(logging.DEBUG)
|
|
|
|
pipeline_manager = pipeline.setup_pipeline(
|
|
transformer.TransformerExtensionManager(
|
|
'ceilometer.transformer',
|
|
),
|
|
)
|
|
|
|
with pipeline_manager.publisher(context.get_admin_context()) as p:
|
|
p([sample.Sample(
|
|
name=cfg.CONF.sample_name,
|
|
type=cfg.CONF.sample_type,
|
|
unit=cfg.CONF.sample_unit,
|
|
volume=cfg.CONF.sample_volume,
|
|
user_id=cfg.CONF.sample_user,
|
|
project_id=cfg.CONF.sample_project,
|
|
resource_id=cfg.CONF.sample_resource,
|
|
timestamp=cfg.CONF.sample_timestamp,
|
|
resource_metadata=cfg.CONF.sample_metadata and eval(
|
|
cfg.CONF.sample_metadata))])
|