aodh/ceilometer/dispatcher/database.py
Martin Geisler d7054053ae Remove (c) and remove unnecessary encoding lines
The word "Copyright" alone is sufficient to claim copyright, the (c)
symbol need not be present.[1]

As per PEP 263, a Python file with non-ASCII characters must have a
line with "coding: <some-encoding>". Python files containing only
7-bit ASCII characters need no such line.[2]

This commit removes unnecessary Unicode copyright symbols and
unnecessary encoding lines.

[1]: http://www.copyright.gov/circs/circ03.pdf
[2]: http://legacy.python.org/dev/peps/pep-0263/

Closes-Bug: #1324686
Change-Id: Id381ea1f029a0cfddd3773c6d9f16c47842d9c33
2014-05-31 13:02:21 +02:00

80 lines
3.1 KiB
Python

#
# Copyright 2013 IBM Corp
#
# Author: Tong Li <litong01@us.ibm.com>
#
# Licensed under the Apache License, Version 2.0 (the "License"); you may
# not use this file except in compliance with the License. You may obtain
# a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS, WITHOUT
# WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the
# License for the specific language governing permissions and limitations
# under the License.
from ceilometer import dispatcher
from ceilometer.openstack.common.gettextutils import _
from ceilometer.openstack.common import log
from ceilometer.openstack.common import timeutils
from ceilometer.publisher import utils as publisher_utils
from ceilometer import storage
LOG = log.getLogger(__name__)
class DatabaseDispatcher(dispatcher.Base):
'''Dispatcher class for recording metering data into database.
The dispatcher class which records each meter into a database configured
in ceilometer configuration file.
To enable this dispatcher, the following section needs to be present in
ceilometer.conf file
dispatchers = database
'''
def __init__(self, conf):
super(DatabaseDispatcher, self).__init__(conf)
self.storage_conn = storage.get_connection_from_config(conf)
def record_metering_data(self, data):
# We may have receive only one counter on the wire
if not isinstance(data, list):
data = [data]
for meter in data:
LOG.debug(_(
'metering data %(counter_name)s '
'for %(resource_id)s @ %(timestamp)s: %(counter_volume)s')
% ({'counter_name': meter['counter_name'],
'resource_id': meter['resource_id'],
'timestamp': meter.get('timestamp', 'NO TIMESTAMP'),
'counter_volume': meter['counter_volume']}))
if publisher_utils.verify_signature(
meter,
self.conf.publisher.metering_secret):
try:
# Convert the timestamp to a datetime instance.
# Storage engines are responsible for converting
# that value to something they can store.
if meter.get('timestamp'):
ts = timeutils.parse_isotime(meter['timestamp'])
meter['timestamp'] = timeutils.normalize_time(ts)
self.storage_conn.record_metering_data(meter)
except Exception as err:
LOG.exception(_('Failed to record metering data: %s'),
err)
else:
LOG.warning(_(
'message signature invalid, discarding message: %r'),
meter)
def record_events(self, events):
if not isinstance(events, list):
events = [events]
return self.storage_conn.record_events(events)