aodh/ceilometer/collector/service.py
Doug Hellmann 7d8bd50d08 Decouple the nova notifier from ceilometer code
The move to oslo.config introduced a conflict in the nova notifier
because both nova and ceilometer have copies of the
openstack.common.rpc library and define an option for the AMQP
exchange name for the project. This changeset decouples the notifier
plugin in ceilometer from most of the ceilometer code, to remove that
conflict.

The nova notifier is rewritten to emit a new notification message with
event type `compute.instance.delete.samples` instead of making the old
RPC calls directly to the ceilometer collector, and a notification
listener plugin is provided to convert those messages to sample data.

The notifier implementations are split between the one that worked
in folsom and the one that works in grizzly to maintain backwards
compatibility.

get_hypervisor_inspector() is moved to a location where it can be
imported both by the compute agent manager and the notifier
plugin. The definition of `disabled_compute_pollsters` option is also
moved for the same reason.

The tox configuration is changed to run the nova notifier tests
separately from the other tests, since nose cannot import nova and
ceilometer code in the same process.

bug 1130952

Change-Id: I39ba4564c9c14f09dbdd768d7a83f6940e3942ad
Signed-off-by: Doug Hellmann <doug.hellmann@dreamhost.com>
2013-02-26 14:22:27 -05:00

158 lines
6.2 KiB
Python

# -*- encoding: utf-8 -*-
#
# Copyright © 2012 eNovance <licensing@enovance.com>
#
# Author: Julien Danjou <julien@danjou.info>
#
# Licensed under the Apache License, Version 2.0 (the "License"); you may
# not use this file except in compliance with the License. You may obtain
# a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS, WITHOUT
# WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the
# License for the specific language governing permissions and limitations
# under the License.
from oslo.config import cfg
from stevedore import dispatch
from ceilometer.collector import meter as meter_api
from ceilometer import extension_manager
from ceilometer import pipeline
from ceilometer import service
from ceilometer import storage
from ceilometer.openstack.common import context
from ceilometer.openstack.common import log
from ceilometer.openstack.common import timeutils
from ceilometer.openstack.common.rpc import dispatcher as rpc_dispatcher
# Import rpc_notifier to register `notification_topics` flag so that
# plugins can use it
# FIXME(dhellmann): Use option importing feature of oslo.config instead.
import ceilometer.openstack.common.notifier.rpc_notifier
OPTS = [
cfg.ListOpt('disabled_notification_listeners',
default=[],
help='list of listener plugins to disable',
),
]
cfg.CONF.register_opts(OPTS)
LOG = log.getLogger(__name__)
class CollectorService(service.PeriodicService):
COLLECTOR_NAMESPACE = 'ceilometer.collector'
def start(self):
super(CollectorService, self).start()
storage.register_opts(cfg.CONF)
self.storage_engine = storage.get_engine(cfg.CONF)
self.storage_conn = self.storage_engine.get_connection(cfg.CONF)
def initialize_service_hook(self, service):
'''Consumers must be declared before consume_thread start.'''
LOG.debug('initialize_service_hooks')
publisher_manager = dispatch.NameDispatchExtensionManager(
namespace=pipeline.PUBLISHER_NAMESPACE,
check_func=lambda x: True,
invoke_on_load=True,
)
self.pipeline_manager = pipeline.setup_pipeline(publisher_manager)
LOG.debug('loading notification handlers from %s',
self.COLLECTOR_NAMESPACE)
self.notification_manager = \
extension_manager.ActivatedExtensionManager(
namespace=self.COLLECTOR_NAMESPACE,
disabled_names=cfg.CONF.disabled_notification_listeners,
)
if not list(self.notification_manager):
LOG.warning('Failed to load any notification handlers for %s',
self.COLLECTOR_NAMESPACE)
self.notification_manager.map(self._setup_subscription)
# Set ourselves up as a separate worker for the metering data,
# since the default for service is to use create_consumer().
self.conn.create_worker(
cfg.CONF.metering_topic,
rpc_dispatcher.RpcDispatcher([self]),
'ceilometer.collector.' + cfg.CONF.metering_topic,
)
def _setup_subscription(self, ext, *args, **kwds):
handler = ext.obj
LOG.debug('Event types from %s: %s',
ext.name, ', '.join(handler.get_event_types()))
for exchange_topic in handler.get_exchange_topics(cfg.CONF):
for topic in exchange_topic.topics:
try:
self.conn.join_consumer_pool(
callback=self.process_notification,
pool_name='ceilometer.notifications',
topic=topic,
exchange_name=exchange_topic.exchange,
)
except Exception:
LOG.exception('Could not join consumer pool %s/%s' %
(topic, exchange_topic.exchange))
def process_notification(self, notification):
"""Make a notification processed by an handler."""
LOG.debug('notification %r', notification.get('event_type'))
self.notification_manager.map(self._process_notification_for_ext,
notification=notification,
)
def _process_notification_for_ext(self, ext, notification):
handler = ext.obj
if notification['event_type'] in handler.get_event_types():
ctxt = context.get_admin_context()
with self.pipeline_manager.publisher(ctxt,
cfg.CONF.counter_source) as p:
# FIXME(dhellmann): Spawn green thread?
p(list(handler.process_notification(notification)))
def record_metering_data(self, context, data):
"""This method is triggered when metering data is
cast from an agent.
"""
# We may have receive only one counter on the wire
if not isinstance(data, list):
data = [data]
for meter in data:
LOG.info('metering data %s for %s @ %s: %s',
meter['counter_name'],
meter['resource_id'],
meter.get('timestamp', 'NO TIMESTAMP'),
meter['counter_volume'])
if meter_api.verify_signature(meter, cfg.CONF.metering_secret):
try:
# Convert the timestamp to a datetime instance.
# Storage engines are responsible for converting
# that value to something they can store.
if meter.get('timestamp'):
ts = timeutils.parse_isotime(meter['timestamp'])
meter['timestamp'] = timeutils.normalize_time(ts)
self.storage_conn.record_metering_data(meter)
except Exception as err:
LOG.error('Failed to record metering data: %s', err)
LOG.exception(err)
else:
LOG.warning(
'message signature invalid, discarding message: %r',
meter)
def periodic_tasks(self, context):