Merge "Allow log directories to be configured"
This commit is contained in:
commit
9bf485b0ae
@ -155,6 +155,15 @@ remote_syslog_server: String value, default undefined. If set, rsyslog is
|
||||
remote_syslog_port: String value, default is 514. If set, custom port is
|
||||
configured for remote syslog server.
|
||||
|
||||
ironic_log_dir: String value, default undefined. If set, it specifies a
|
||||
a non-default log directory for ironic.
|
||||
|
||||
inspector_log_dir: String value, default undefined. If set, it specifies a
|
||||
non-default log directory for inspector.
|
||||
|
||||
nginx_log_dir: String value, default /var/log/nginx. It specifies a log
|
||||
directory for nginx.
|
||||
|
||||
### Hardware Inspection Support
|
||||
|
||||
Bifrost also supports the installation of ironic-inspector in standalone
|
||||
|
@ -133,6 +133,15 @@ inspector_manage_firewall: false
|
||||
# Deprecated: ironic_auth_strategy will be removed in Pike.
|
||||
ironic_auth_strategy: "noauth"
|
||||
|
||||
# Set ironic_log_dir to use a non-default log directory for ironic.
|
||||
#ironic_log_dir:
|
||||
|
||||
# Set inspector_log_dir to use a non-default log directory for inspector.
|
||||
#inspector_log_dir:
|
||||
|
||||
# Set nginx_log_dir to use a non-default log directory for nginx.
|
||||
nginx_log_dir: /var/log/nginx
|
||||
|
||||
inspector_data_dir: "/opt/stack/ironic-inspector/var"
|
||||
inspector_store_ramdisk_logs: true
|
||||
# Note: inspector_port_addition has three valid values: all, active, pxe
|
||||
|
@ -11,6 +11,10 @@ auth_strategy = {{ inspector_auth | default('noauth') }}
|
||||
{% endif %}
|
||||
debug = {{ inspector_debug | bool }}
|
||||
|
||||
{% if inspector_log_dir is defined %}
|
||||
log_dir = {{ inspector_log_dir }}
|
||||
{% endif %}
|
||||
|
||||
[database]
|
||||
connection=mysql+pymysql://{{ ironic_inspector.database.username }}:{{ ironic_inspector.database.password }}@{{ ironic_inspector.database.host }}/{{ ironic_inspector.database.name }}?charset=utf8
|
||||
|
||||
|
@ -26,6 +26,10 @@ auth_strategy = keystone
|
||||
auth_strategy = noauth
|
||||
{% endif %}
|
||||
|
||||
{% if ironic_log_dir is defined %}
|
||||
log_dir = {{ ironic_log_dir }}
|
||||
{% endif %}
|
||||
|
||||
[pxe]
|
||||
pxe_append_params = systemd.journald.forward_to_console=yes {{ extra_kernel_options | default('') }}
|
||||
pxe_config_template = $pybasedir/drivers/modules/ipxe_config.template
|
||||
|
@ -30,8 +30,8 @@ http {
|
||||
# Logging Settings
|
||||
##
|
||||
|
||||
access_log /var/log/nginx/access.log;
|
||||
error_log /var/log/nginx/error.log;
|
||||
access_log {{ nginx_log_dir }}/access.log;
|
||||
error_log {{ nginx_log_dir }}/error.log;
|
||||
|
||||
##
|
||||
# Gzip Settings
|
||||
|
11
releasenotes/notes/log-directories-87b86df40464bb2d.yaml
Normal file
11
releasenotes/notes/log-directories-87b86df40464bb2d.yaml
Normal file
@ -0,0 +1,11 @@
|
||||
---
|
||||
features:
|
||||
- |
|
||||
Allows log directories to be configured
|
||||
|
||||
In some cases it is useful to be able to configure the directory into which
|
||||
log files are written by bifrost services.
|
||||
|
||||
It is now possible to configure the ironic, inspector and nginx log
|
||||
directories using the ``ironic_log_dir``, ``inspector_log_dir``, and
|
||||
``nginx_log_dir`` variables respectively.
|