diskimage-builder/elements/ilo
Gregory Haynes c4bbb6f3bc Create docs site containing element READMEs
We currently do not have the ability to create a docs site which
outlines all the elements.

Change-Id: I77ccf61e0c4b1509b3e7ce9b8f15ea5ccfd50d9b
2015-02-10 11:45:35 -08:00
..
extra-data.d Add support for flashing ILO BMC's from ramdisks 2014-08-28 17:07:03 +01:00
init.d Add support for flashing ILO BMC's from ramdisks 2014-08-28 17:07:03 +01:00
ramdisk-install.d Add support for flashing ILO BMC's from ramdisks 2014-08-28 17:07:03 +01:00
README.rst Create docs site containing element READMEs 2015-02-10 11:45:35 -08:00

ilo

Ramdisk support for applying HP iLO firmware.

The firmware files are copied in via an extra-data hook: the variable DIB_ILO_FIRMWARE_PATH specifies a directory, and every file in that directory will be unpacked into a same-named directory in the ramdisk (using --unpack=...). If the path is not specified, a diagnostic is output but no error is triggered.

During ramdisk init every found firmware installer will be executed using --silent --log=log The log is displayed after the firmware has executed.

If the firmware exits with status 0 (ok), status 2 (same or older version) or 4 (ilo not detected) a diagnostic message is logged and init proceeds.

Any other status code is treated as an error.