diff --git a/doc/source/drivers/ilo.rst b/doc/source/drivers/ilo.rst index 3cc103094c..20e5ab0a31 100644 --- a/doc/source/drivers/ilo.rst +++ b/doc/source/drivers/ilo.rst @@ -305,6 +305,12 @@ Nodes configured for iLO driver should have the ``driver`` property set to `ilo_address` while enrolling node to Bare Metal service to avoid SSL certificate validation errors related to hostname mismatch. +.. note:: + If configuration values for ``ca_file``, ``client_port`` and + ``client_timeout`` are not provided in the ``driver_info`` of the node, + the corresponding config variables defined under ``[ilo]`` section in + ironic.conf will be used. + For example, you could run a similar command like below to enroll the ProLiant node:: @@ -451,6 +457,12 @@ Nodes configured for iLO driver should have the ``driver`` property set to `ilo_address` while enrolling node to Bare Metal service to avoid SSL certificate validation errors related to hostname mismatch. +.. note:: + If configuration values for ``ca_file``, ``client_port`` and + ``client_timeout`` are not provided in the ``driver_info`` of the node, + the corresponding config variables defined under ``[ilo]`` section in + ironic.conf will be used. + For example, you could run a similar command like below to enroll the ProLiant node:: @@ -579,6 +591,12 @@ Nodes configured for iLO driver should have the ``driver`` property set to `ilo_address` while enrolling node to Bare Metal service to avoid SSL certificate validation errors related to hostname mismatch. +.. note:: + If configuration values for ``ca_file``, ``client_port`` and + ``client_timeout`` are not provided in the ``driver_info`` of the node, + the corresponding config variables defined under ``[ilo]`` section in + ironic.conf will be used. + For example, you could run a similar command like below to enroll the ProLiant node:: @@ -1504,8 +1522,21 @@ All the fields in the firmware image block are mandatory. RAID Support ^^^^^^^^^^^^ -The inband RAID functionality is now supported by iLO drivers. -See :ref:`raid` for more information. +The inband RAID functionality is supported by iLO drivers. See :ref:`raid` +for more information. +Bare Metal service update node with following information after successful +configuration of RAID: + +* Node ``properties/local_gb`` is set to the size of root volume. +* Node ``properties/root_device`` is filled with ``wwn`` details of root + volume. It is used by iLO drivers as root device hint during provisioning. +* The value of raid level of root volume is added as ``raid_level`` capability + to the node's ``capabilities`` parameter within ``properties`` field. The + operator can specify the ``raid_level`` capability in nova flavor for node + to be selected for scheduling:: + + nova flavor-key ironic-test set capabilities:raid_level="1+0" + nova boot --flavor ironic-test --image test-image instance-1 .. _DIB_raid_support: