A few fixes in Multitenancy document
This patch fixes the following items in Multitenancy documentation[1]. - A security group rule for iSCSI should be ingress because a node is connected from ironic conductor. - A URL of an article of ML2 plugin configuration has been changed at Newton. [1] http://docs.openstack.org/developer/ironic/deploy/multitenancy.html Change-Id: I65400cd6717ce4d9c23f41a20f24ee96f9415c4d
This commit is contained in:
parent
fd089b0a01
commit
10260a173e
@ -98,7 +98,7 @@ interface as stated above):
|
||||
* egress port used for ironic (6385 by default)
|
||||
* ingress port used for ironic-python-agent (9999 by default)
|
||||
* if using the iSCSI deploy method (``pxe_*`` and ``iscsi_*`` drivers),
|
||||
the egress port used for iSCSI (3260 by default)
|
||||
the ingress port used for iSCSI (3260 by default)
|
||||
* if using the direct deploy method (``agent_*`` drivers), the egress
|
||||
port used for swift (typically 80 or 443)
|
||||
* if using iPXE, the egress port used for the HTTP server running
|
||||
@ -106,7 +106,7 @@ interface as stated above):
|
||||
|
||||
#. Install and configure a compatible ML2 mechanism driver which supports bare
|
||||
metal provisioning for your switch. See `ML2 plugin configuration manual
|
||||
<http://docs.openstack.org/networking-guide/config-ml2-plug-in.html>`_
|
||||
<http://docs.openstack.org/networking-guide/config-ml2.html>`_
|
||||
for details.
|
||||
|
||||
#. Restart the ironic conductor and API services after the modifications:
|
||||
|
Loading…
x
Reference in New Issue
Block a user