Merge "Make generation of ironic.conf.sample deterministic"

This commit is contained in:
Jenkins 2015-09-25 14:57:50 +00:00 committed by Gerrit Code Review
commit 4f5651de18
2 changed files with 220 additions and 222 deletions

View File

@ -1,210 +1,5 @@
[DEFAULT]
#
# Options defined in oslo.log
#
# Print debugging output (set logging level to DEBUG instead
# of default INFO level). (boolean value)
#debug=false
# If set to false, will disable INFO logging level, making
# WARNING the default. (boolean value)
#verbose=true
# The name of a logging configuration file. This file is
# appended to any existing logging configuration files. For
# details about logging configuration files, see the Python
# logging module documentation. (string value)
# Deprecated group/name - [DEFAULT]/log_config
#log_config_append=<None>
# DEPRECATED. A logging.Formatter log message format string
# which may use any of the available logging.LogRecord
# attributes. This option is deprecated. Please use
# logging_context_format_string and
# logging_default_format_string instead. (string value)
#log_format=<None>
# Format string for %%(asctime)s in log records. Default:
# %(default)s . (string value)
#log_date_format=%Y-%m-%d %H:%M:%S
# (Optional) Name of log file to output to. If no default is
# set, logging will go to stdout. (string value)
# Deprecated group/name - [DEFAULT]/logfile
#log_file=<None>
# (Optional) The base directory used for relative --log-file
# paths. (string value)
# Deprecated group/name - [DEFAULT]/logdir
#log_dir=<None>
# Use syslog for logging. Existing syslog format is DEPRECATED
# and will be changed later to honor RFC5424. (boolean value)
#use_syslog=false
# (Optional) Enables or disables syslog rfc5424 format for
# logging. If enabled, prefixes the MSG part of the syslog
# message with APP-NAME (RFC5424). The format without the APP-
# NAME is deprecated in Kilo, and will be removed in Mitaka,
# along with this option. (boolean value)
#use_syslog_rfc_format=true
# Syslog facility to receive log lines. (string value)
#syslog_log_facility=LOG_USER
# Log output to standard error. (boolean value)
#use_stderr=true
# Format string to use for log messages with context. (string
# value)
#logging_context_format_string=%(asctime)s.%(msecs)03d %(process)d %(levelname)s %(name)s [%(request_id)s %(user_identity)s] %(instance)s%(message)s
# Format string to use for log messages without context.
# (string value)
#logging_default_format_string=%(asctime)s.%(msecs)03d %(process)d %(levelname)s %(name)s [-] %(instance)s%(message)s
# Data to append to log format when level is DEBUG. (string
# value)
#logging_debug_format_suffix=%(funcName)s %(pathname)s:%(lineno)d
# Prefix each line of exception output with this format.
# (string value)
#logging_exception_prefix=%(asctime)s.%(msecs)03d %(process)d ERROR %(name)s %(instance)s
# List of logger=LEVEL pairs. (list value)
#default_log_levels=amqp=WARN,amqplib=WARN,boto=WARN,qpid=WARN,sqlalchemy=WARN,suds=INFO,oslo.messaging=INFO,iso8601=WARN,requests.packages.urllib3.connectionpool=WARN,urllib3.connectionpool=WARN,websocket=WARN,requests.packages.urllib3.util.retry=WARN,urllib3.util.retry=WARN,keystonemiddleware=WARN,routes.middleware=WARN,stevedore=WARN,taskflow=WARN
# Enables or disables publication of error events. (boolean
# value)
#publish_errors=false
# The format for an instance that is passed with the log
# message. (string value)
#instance_format="[instance: %(uuid)s] "
# The format for an instance UUID that is passed with the log
# message. (string value)
#instance_uuid_format="[instance: %(uuid)s] "
# Enables or disables fatal status of deprecations. (boolean
# value)
#fatal_deprecations=false
#
# Options defined in oslo.service.service
#
# Enable eventlet backdoor. Acceptable values are 0, <port>,
# and <start>:<end>, where 0 results in listening on a random
# tcp port number; <port> results in listening on the
# specified port number (and not enabling backdoor if that
# port is in use); and <start>:<end> results in listening on
# the smallest unused port number within the specified range
# of port numbers. The chosen port is displayed in the
# service's log file. (string value)
#backdoor_port=<None>
# Enables or disables logging values of all registered options
# when starting a service (at DEBUG level). (boolean value)
#log_options=true
#
# Options defined in oslo.service.periodic_task
#
# Some periodic tasks can be run in a separate process. Should
# we run them here? (boolean value)
#run_external_periodic_tasks=true
#
# Options defined in oslo.messaging
#
# Size of RPC connection pool. (integer value)
#rpc_conn_pool_size=30
# ZeroMQ bind address. Should be a wildcard (*), an ethernet
# interface, or IP. The "host" option should point or resolve
# to this address. (string value)
#rpc_zmq_bind_address=*
# MatchMaker driver. (string value)
#rpc_zmq_matchmaker=local
# ZeroMQ receiver listening port. (integer value)
#rpc_zmq_port=9501
# Number of ZeroMQ contexts, defaults to 1. (integer value)
#rpc_zmq_contexts=1
# Maximum number of ingress messages to locally buffer per
# topic. Default is unlimited. (integer value)
#rpc_zmq_topic_backlog=<None>
# Directory for holding IPC sockets. (string value)
#rpc_zmq_ipc_dir=/var/run/openstack
# Name of this node. Must be a valid hostname, FQDN, or IP
# address. Must match "host" option, if running Nova. (string
# value)
#rpc_zmq_host=ironic
# Seconds to wait before a cast expires (TTL). Only supported
# by impl_zmq. (integer value)
#rpc_cast_timeout=30
# Heartbeat frequency. (integer value)
#matchmaker_heartbeat_freq=300
# Heartbeat time-to-live. (integer value)
#matchmaker_heartbeat_ttl=600
# Size of executor thread pool. (integer value)
# Deprecated group/name - [DEFAULT]/rpc_thread_pool_size
#executor_thread_pool_size=64
# The Drivers(s) to handle sending notifications. Possible
# values are messaging, messagingv2, routing, log, test, noop
# (multi valued)
#notification_driver=
# AMQP topic used for OpenStack notifications. (list value)
# Deprecated group/name - [rpc_notifier2]/topics
#notification_topics=notifications
# Seconds to wait for a response from a call. (integer value)
#rpc_response_timeout=60
# A URL representing the messaging driver to use and its full
# configuration. If not set, we fall back to the rpc_backend
# option and driver specific configuration. (string value)
#transport_url=<None>
# The messaging driver to use, defaults to rabbit. Other
# drivers include qpid and zmq. (string value)
#rpc_backend=rabbit
# The default exchange under which topics are scoped. May be
# overridden by an exchange name specified in the
# transport_url option. (string value)
#control_exchange=openstack
#
# Options defined in ironic.netconf
#
# IP address of this host. If unset, will determine the IP
# programmatically. If unable to do so, will use "127.0.0.1".
# (string value)
#my_ip=10.0.0.1
#
# Options defined in ironic.api.app
#
@ -346,6 +141,211 @@
#parallel_image_downloads=false
#
# Options defined in ironic.netconf
#
# IP address of this host. If unset, will determine the IP
# programmatically. If unable to do so, will use "127.0.0.1".
# (string value)
#my_ip=10.0.0.1
#
# Options defined in oslo.log
#
# Print debugging output (set logging level to DEBUG instead
# of default INFO level). (boolean value)
#debug=false
# If set to false, will disable INFO logging level, making
# WARNING the default. (boolean value)
#verbose=true
# The name of a logging configuration file. This file is
# appended to any existing logging configuration files. For
# details about logging configuration files, see the Python
# logging module documentation. (string value)
# Deprecated group/name - [DEFAULT]/log_config
#log_config_append=<None>
# DEPRECATED. A logging.Formatter log message format string
# which may use any of the available logging.LogRecord
# attributes. This option is deprecated. Please use
# logging_context_format_string and
# logging_default_format_string instead. (string value)
#log_format=<None>
# Format string for %%(asctime)s in log records. Default:
# %(default)s . (string value)
#log_date_format=%Y-%m-%d %H:%M:%S
# (Optional) Name of log file to output to. If no default is
# set, logging will go to stdout. (string value)
# Deprecated group/name - [DEFAULT]/logfile
#log_file=<None>
# (Optional) The base directory used for relative --log-file
# paths. (string value)
# Deprecated group/name - [DEFAULT]/logdir
#log_dir=<None>
# Use syslog for logging. Existing syslog format is DEPRECATED
# and will be changed later to honor RFC5424. (boolean value)
#use_syslog=false
# (Optional) Enables or disables syslog rfc5424 format for
# logging. If enabled, prefixes the MSG part of the syslog
# message with APP-NAME (RFC5424). The format without the APP-
# NAME is deprecated in Kilo, and will be removed in Mitaka,
# along with this option. (boolean value)
#use_syslog_rfc_format=true
# Syslog facility to receive log lines. (string value)
#syslog_log_facility=LOG_USER
# Log output to standard error. (boolean value)
#use_stderr=true
# Format string to use for log messages with context. (string
# value)
#logging_context_format_string=%(asctime)s.%(msecs)03d %(process)d %(levelname)s %(name)s [%(request_id)s %(user_identity)s] %(instance)s%(message)s
# Format string to use for log messages without context.
# (string value)
#logging_default_format_string=%(asctime)s.%(msecs)03d %(process)d %(levelname)s %(name)s [-] %(instance)s%(message)s
# Data to append to log format when level is DEBUG. (string
# value)
#logging_debug_format_suffix=%(funcName)s %(pathname)s:%(lineno)d
# Prefix each line of exception output with this format.
# (string value)
#logging_exception_prefix=%(asctime)s.%(msecs)03d %(process)d ERROR %(name)s %(instance)s
# List of logger=LEVEL pairs. (list value)
#default_log_levels=amqp=WARN,amqplib=WARN,boto=WARN,qpid=WARN,sqlalchemy=WARN,suds=INFO,oslo.messaging=INFO,iso8601=WARN,requests.packages.urllib3.connectionpool=WARN,urllib3.connectionpool=WARN,websocket=WARN,requests.packages.urllib3.util.retry=WARN,urllib3.util.retry=WARN,keystonemiddleware=WARN,routes.middleware=WARN,stevedore=WARN,taskflow=WARN
# Enables or disables publication of error events. (boolean
# value)
#publish_errors=false
# The format for an instance that is passed with the log
# message. (string value)
#instance_format="[instance: %(uuid)s] "
# The format for an instance UUID that is passed with the log
# message. (string value)
#instance_uuid_format="[instance: %(uuid)s] "
# Enables or disables fatal status of deprecations. (boolean
# value)
#fatal_deprecations=false
#
# Options defined in oslo.messaging
#
# Size of RPC connection pool. (integer value)
#rpc_conn_pool_size=30
# ZeroMQ bind address. Should be a wildcard (*), an ethernet
# interface, or IP. The "host" option should point or resolve
# to this address. (string value)
#rpc_zmq_bind_address=*
# MatchMaker driver. (string value)
#rpc_zmq_matchmaker=local
# ZeroMQ receiver listening port. (integer value)
#rpc_zmq_port=9501
# Number of ZeroMQ contexts, defaults to 1. (integer value)
#rpc_zmq_contexts=1
# Maximum number of ingress messages to locally buffer per
# topic. Default is unlimited. (integer value)
#rpc_zmq_topic_backlog=<None>
# Directory for holding IPC sockets. (string value)
#rpc_zmq_ipc_dir=/var/run/openstack
# Name of this node. Must be a valid hostname, FQDN, or IP
# address. Must match "host" option, if running Nova. (string
# value)
#rpc_zmq_host=ironic
# Seconds to wait before a cast expires (TTL). Only supported
# by impl_zmq. (integer value)
#rpc_cast_timeout=30
# Heartbeat frequency. (integer value)
#matchmaker_heartbeat_freq=300
# Heartbeat time-to-live. (integer value)
#matchmaker_heartbeat_ttl=600
# Size of executor thread pool. (integer value)
# Deprecated group/name - [DEFAULT]/rpc_thread_pool_size
#executor_thread_pool_size=64
# The Drivers(s) to handle sending notifications. Possible
# values are messaging, messagingv2, routing, log, test, noop
# (multi valued)
#notification_driver=
# AMQP topic used for OpenStack notifications. (list value)
# Deprecated group/name - [rpc_notifier2]/topics
#notification_topics=notifications
# Seconds to wait for a response from a call. (integer value)
#rpc_response_timeout=60
# A URL representing the messaging driver to use and its full
# configuration. If not set, we fall back to the rpc_backend
# option and driver specific configuration. (string value)
#transport_url=<None>
# The messaging driver to use, defaults to rabbit. Other
# drivers include qpid and zmq. (string value)
#rpc_backend=rabbit
# The default exchange under which topics are scoped. May be
# overridden by an exchange name specified in the
# transport_url option. (string value)
#control_exchange=openstack
#
# Options defined in oslo.service.periodic_task
#
# Some periodic tasks can be run in a separate process. Should
# we run them here? (boolean value)
#run_external_periodic_tasks=true
#
# Options defined in oslo.service.service
#
# Enable eventlet backdoor. Acceptable values are 0, <port>,
# and <start>:<end>, where 0 results in listening on a random
# tcp port number; <port> results in listening on the
# specified port number (and not enabling backdoor if that
# port is in use); and <start>:<end> results in listening on
# the smallest unused port number within the specified range
# of port numbers. The chosen port is displayed in the
# service's log file. (string value)
#backdoor_port=<None>
# Enables or disables logging values of all registered options
# when starting a service (at DEBUG level). (boolean value)
#log_options=true
[agent]
#
@ -369,11 +369,11 @@
# Deprecated group/name - [agent]/manage_tftp
#manage_agent_boot=true
# The memory size in MiB consumed by agent when it is booted on a
# bare metal node. This is used for checking if the image can
# be downloaded and deployed on the bare metal node after booting
# agent ramdisk. This may be set according to the memory
# consumed by the agent ramdisk image. (integer value)
# The memory size in MiB consumed by agent when it is booted
# on a bare metal node. This is used for checking if the image
# can be downloaded and deployed on the bare metal node after
# booting agent ramdisk. This may be set according to the
# memory consumed by the agent ramdisk image. (integer value)
#memory_consumed_by_agent=0
@ -682,6 +682,14 @@
[database]
#
# Options defined in ironic.db.sqlalchemy.models
#
# MySQL engine to use. (string value)
#mysql_engine=InnoDB
#
# Options defined in oslo.db
#
@ -790,14 +798,6 @@
#db_max_retries=20
#
# Options defined in ironic.db.sqlalchemy.models
#
# MySQL engine to use. (string value)
#mysql_engine=InnoDB
[deploy]
#

View File

@ -155,9 +155,7 @@ def _import_module(mod_str):
def _is_in_group(opt, group):
"""Check if opt is in group."""
for value in group._opts.values():
# NOTE(llu): Temporary workaround for bug #1262148, wait until
# newly released oslo.config support '==' operator.
if not(value['opt'] != opt):
if value['opt'] is opt:
return True
return False
@ -215,7 +213,7 @@ def _list_opts(obj):
def print_group_opts(group, opts_by_module):
print("[%s]" % group)
print('')
for mod, opts in opts_by_module:
for mod, opts in sorted(opts_by_module, key=lambda x: x[0]):
print('#')
print('# Options defined in %s' % mod)
print('#')