Clean up RAID documentation
* Use more copy-paste friendly indentation in the examples * Use subheadings for properties * Render JSON examples as JSON * Remove explicit API version from CLI, we've been defaulting to latest for several releases. * Small fixes Change-Id: I1cae6e9b4ff124e3404bd55638bc77bdf3465fe0
This commit is contained in:
parent
71b7441b78
commit
7a3d9a664e
@ -60,13 +60,11 @@ as the key. The value for the ``logical_disks`` is a list of JSON
|
||||
dictionaries. It looks like::
|
||||
|
||||
{
|
||||
"logical_disks": [
|
||||
{<desired properties of logical disk 1>},
|
||||
{<desired properties of logical disk 2>},
|
||||
.
|
||||
.
|
||||
.
|
||||
]
|
||||
"logical_disks": [
|
||||
{<desired properties of logical disk 1>},
|
||||
{<desired properties of logical disk 2>},
|
||||
...
|
||||
]
|
||||
}
|
||||
|
||||
If the ``target_raid_config`` is an empty dictionary, it unsets the value of
|
||||
@ -76,76 +74,74 @@ done on the node.
|
||||
Each dictionary of logical disk contains the desired properties of logical
|
||||
disk supported by the hardware type. These properties are discoverable by::
|
||||
|
||||
openstack baremetal --os-baremetal-api-version 1.15 driver raid property list <driver name>
|
||||
openstack baremetal driver raid property list <driver name>
|
||||
|
||||
The RAID feature is available in ironic API version 1.15 and above.
|
||||
If ``--os-baremetal-api-version`` is not used in the CLI, it will error out
|
||||
with the following message::
|
||||
Mandatory properties
|
||||
^^^^^^^^^^^^^^^^^^^^
|
||||
|
||||
No API version was specified and the requested operation was not
|
||||
supported by the client's negotiated API version 1.9. Supported
|
||||
version range is: 1.1 to ...
|
||||
These properties must be specified for each logical
|
||||
disk and have no default values:
|
||||
|
||||
where the "..." in above error message would be the maximum version
|
||||
supported by the service.
|
||||
- ``size_gb`` - Size (Integer) of the logical disk to be created in GiB.
|
||||
``MAX`` may be specified if the logical disk should use all of the
|
||||
remaining space available. This can be used only when backing physical
|
||||
disks are specified (see below).
|
||||
|
||||
The RAID properties can be split into 4 different types:
|
||||
- ``raid_level`` - RAID level for the logical disk. Ironic supports the
|
||||
following RAID levels: 0, 1, 2, 5, 6, 1+0, 5+0, 6+0.
|
||||
|
||||
#. Mandatory properties. These properties must be specified for each logical
|
||||
disk and have no default values.
|
||||
Optional properties
|
||||
^^^^^^^^^^^^^^^^^^^
|
||||
|
||||
- ``size_gb`` - Size (Integer) of the logical disk to be created in GiB.
|
||||
``MAX`` may be specified if the logical disk should use all of the
|
||||
remaining space available. This can be used only when backing physical
|
||||
disks are specified (see below).
|
||||
These properties have default values and they may be overridden in the
|
||||
specification of any logical disk.
|
||||
|
||||
- ``raid_level`` - RAID level for the logical disk. Ironic supports the
|
||||
following RAID levels: 0, 1, 2, 5, 6, 1+0, 5+0, 6+0.
|
||||
- ``volume_name`` - Name of the volume. Should be unique within the Node.
|
||||
If not specified, volume name will be auto-generated.
|
||||
|
||||
#. Optional properties. These properties have default values and
|
||||
they may be overridden in the specification of any logical disk.
|
||||
- ``is_root_volume`` - Set to ``true`` if this is the root volume. At
|
||||
most one logical disk can have this set to ``true``; the other
|
||||
logical disks must have this set to ``false``. The
|
||||
``root device hint`` will be saved, if the RAID interface is capable of
|
||||
retrieving it. This is ``false`` by default.
|
||||
|
||||
- ``volume_name`` - Name of the volume. Should be unique within the Node.
|
||||
If not specified, volume name will be auto-generated.
|
||||
Backing physical disk hints
|
||||
^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
||||
|
||||
- ``is_root_volume`` - Set to ``true`` if this is the root volume. At
|
||||
most one logical disk can have this set to ``true``; the other
|
||||
logical disks must have this set to ``false``. The
|
||||
``root device hint`` will be saved, if the RAID interface is capable of
|
||||
retrieving it. This is ``false`` by default.
|
||||
These hints are specified for each logical disk to let Ironic find the desired
|
||||
disks for RAID configuration. This is machine-independent information. This
|
||||
serves the use-case where the operator doesn't want to provide individual
|
||||
details for each bare metal node.
|
||||
|
||||
#. Backing physical disk hints. These hints are specified for each logical
|
||||
disk to let Ironic find the desired disks for RAID configuration. This is
|
||||
machine-independent information. This serves the use-case where the
|
||||
operator doesn't want to provide individual details for each bare metal
|
||||
node.
|
||||
- ``share_physical_disks`` - Set to ``true`` if this logical disk can
|
||||
share physical disks with other logical disks. The default value is
|
||||
``false``.
|
||||
|
||||
- ``share_physical_disks`` - Set to ``true`` if this logical disk can
|
||||
share physical disks with other logical disks. The default value is
|
||||
``false``.
|
||||
- ``disk_type`` - ``hdd`` or ``ssd``. If this is not specified, disk type
|
||||
will not be a criterion to find backing physical disks.
|
||||
|
||||
- ``disk_type`` - ``hdd`` or ``ssd``. If this is not specified, disk type
|
||||
will not be a criterion to find backing physical disks.
|
||||
- ``interface_type`` - ``sata`` or ``scsi`` or ``sas``. If this is not
|
||||
specified, interface type will not be a criterion to
|
||||
find backing physical disks.
|
||||
|
||||
- ``interface_type`` - ``sata`` or ``scsi`` or ``sas``. If this is not
|
||||
specified, interface type will not be a criterion to
|
||||
find backing physical disks.
|
||||
- ``number_of_physical_disks`` - Integer, number of disks to use for the
|
||||
logical disk. Defaults to minimum number of disks required for the
|
||||
particular RAID level.
|
||||
|
||||
- ``number_of_physical_disks`` - Integer, number of disks to use for the
|
||||
logical disk. Defaults to minimum number of disks required for the
|
||||
particular RAID level.
|
||||
Backing physical disks
|
||||
^^^^^^^^^^^^^^^^^^^^^^
|
||||
|
||||
#. Backing physical disks. These are the actual machine-dependent
|
||||
information. This is suitable for environments where the operator wants
|
||||
to automate the selection of physical disks with a 3rd-party tool based
|
||||
on a wider range of attributes (eg. S.M.A.R.T. status, physical location).
|
||||
The values for these properties are hardware dependent.
|
||||
These are the actual machine-dependent information. This is suitable for
|
||||
environments where the operator wants to automate the selection of physical
|
||||
disks with a 3rd-party tool based on a wider range of attributes
|
||||
(eg. S.M.A.R.T. status, physical location). The values for these properties
|
||||
are hardware dependent.
|
||||
|
||||
- ``controller`` - The name of the controller as read by the RAID interface.
|
||||
In order to trigger the setup of a Software RAID via the Ironic Python
|
||||
Agent, the value of this property needs to be set to ``software``.
|
||||
- ``physical_disks`` - A list of physical disks to use as read by the
|
||||
RAID interface.
|
||||
- ``controller`` - The name of the controller as read by the RAID interface.
|
||||
In order to trigger the setup of a Software RAID via the Ironic Python
|
||||
Agent, the value of this property needs to be set to ``software``.
|
||||
- ``physical_disks`` - A list of physical disks to use as read by the
|
||||
RAID interface.
|
||||
|
||||
.. note::
|
||||
If properties from both "Backing physical disk hints" or
|
||||
@ -160,97 +156,106 @@ Examples for ``target_raid_config``
|
||||
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
||||
|
||||
*Example 1*. Single RAID disk of RAID level 5 with all of the space
|
||||
available. Make this the root volume to which Ironic deploys the image::
|
||||
available. Make this the root volume to which Ironic deploys the image:
|
||||
|
||||
.. code-block:: json
|
||||
|
||||
{
|
||||
"logical_disks": [
|
||||
{
|
||||
"size_gb": "MAX",
|
||||
"raid_level": "5",
|
||||
"is_root_volume": true
|
||||
}
|
||||
]
|
||||
"logical_disks": [
|
||||
{
|
||||
"size_gb": "MAX",
|
||||
"raid_level": "5",
|
||||
"is_root_volume": true
|
||||
}
|
||||
]
|
||||
}
|
||||
|
||||
*Example 2*. Two RAID disks. One with RAID level 5 of 100 GiB and make it
|
||||
root volume and use SSD. Another with RAID level 1 of 500 GiB and use
|
||||
HDD::
|
||||
HDD:
|
||||
|
||||
.. code-block:: json
|
||||
|
||||
{
|
||||
"logical_disks": [
|
||||
{
|
||||
"size_gb": 100,
|
||||
"raid_level": "5",
|
||||
"is_root_volume": true,
|
||||
"disk_type": "ssd"
|
||||
},
|
||||
{
|
||||
"size_gb": 500,
|
||||
"raid_level": "1",
|
||||
"disk_type": "hdd"
|
||||
}
|
||||
]
|
||||
"logical_disks": [
|
||||
{
|
||||
"size_gb": 100,
|
||||
"raid_level": "5",
|
||||
"is_root_volume": true,
|
||||
"disk_type": "ssd"
|
||||
},
|
||||
{
|
||||
"size_gb": 500,
|
||||
"raid_level": "1",
|
||||
"disk_type": "hdd"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
||||
*Example 3*. Single RAID disk. I know which disks and controller to use::
|
||||
*Example 3*. Single RAID disk. I know which disks and controller to use:
|
||||
|
||||
.. code-block:: json
|
||||
|
||||
{
|
||||
"logical_disks": [
|
||||
{
|
||||
"size_gb": 100,
|
||||
"raid_level": "5",
|
||||
"controller": "Smart Array P822 in Slot 3",
|
||||
"physical_disks": ["6I:1:5", "6I:1:6", "6I:1:7"],
|
||||
"is_root_volume": true
|
||||
}
|
||||
]
|
||||
"logical_disks": [
|
||||
{
|
||||
"size_gb": 100,
|
||||
"raid_level": "5",
|
||||
"controller": "Smart Array P822 in Slot 3",
|
||||
"physical_disks": ["6I:1:5", "6I:1:6", "6I:1:7"],
|
||||
"is_root_volume": true
|
||||
}
|
||||
]
|
||||
}
|
||||
|
||||
*Example 4*. Using backing physical disks::
|
||||
*Example 4*. Using backing physical disks:
|
||||
|
||||
.. code-block:: json
|
||||
|
||||
{
|
||||
"logical_disks":
|
||||
[
|
||||
{
|
||||
"size_gb": 50,
|
||||
"raid_level": "1+0",
|
||||
"controller": "RAID.Integrated.1-1",
|
||||
"volume_name": "root_volume",
|
||||
"is_root_volume": true,
|
||||
"physical_disks": [
|
||||
"Disk.Bay.0:Encl.Int.0-1:RAID.Integrated.1-1",
|
||||
"Disk.Bay.1:Encl.Int.0-1:RAID.Integrated.1-1"
|
||||
]
|
||||
},
|
||||
{
|
||||
"size_gb": 100,
|
||||
"raid_level": "5",
|
||||
"controller": "RAID.Integrated.1-1",
|
||||
"volume_name": "data_volume",
|
||||
"physical_disks": [
|
||||
"Disk.Bay.2:Encl.Int.0-1:RAID.Integrated.1-1",
|
||||
"Disk.Bay.3:Encl.Int.0-1:RAID.Integrated.1-1",
|
||||
"Disk.Bay.4:Encl.Int.0-1:RAID.Integrated.1-1"
|
||||
]
|
||||
}
|
||||
]
|
||||
"logical_disks": [
|
||||
{
|
||||
"size_gb": 50,
|
||||
"raid_level": "1+0",
|
||||
"controller": "RAID.Integrated.1-1",
|
||||
"volume_name": "root_volume",
|
||||
"is_root_volume": true,
|
||||
"physical_disks": [
|
||||
"Disk.Bay.0:Encl.Int.0-1:RAID.Integrated.1-1",
|
||||
"Disk.Bay.1:Encl.Int.0-1:RAID.Integrated.1-1"
|
||||
]
|
||||
},
|
||||
{
|
||||
"size_gb": 100,
|
||||
"raid_level": "5",
|
||||
"controller": "RAID.Integrated.1-1",
|
||||
"volume_name": "data_volume",
|
||||
"physical_disks": [
|
||||
"Disk.Bay.2:Encl.Int.0-1:RAID.Integrated.1-1",
|
||||
"Disk.Bay.3:Encl.Int.0-1:RAID.Integrated.1-1",
|
||||
"Disk.Bay.4:Encl.Int.0-1:RAID.Integrated.1-1"
|
||||
]
|
||||
}
|
||||
]
|
||||
}
|
||||
|
||||
*Example 5*. Software RAID with two RAID devices::
|
||||
*Example 5*. Software RAID with two RAID devices:
|
||||
|
||||
.. code-block:: json
|
||||
|
||||
{
|
||||
"logical_disks": [
|
||||
{
|
||||
"size_gb": 100,
|
||||
"raid_level": "1",
|
||||
"controller": "software"
|
||||
},
|
||||
{
|
||||
"size_gb": "MAX",
|
||||
"raid_level": "0",
|
||||
"controller": "software"
|
||||
}
|
||||
]
|
||||
"logical_disks": [
|
||||
{
|
||||
"size_gb": 100,
|
||||
"raid_level": "1",
|
||||
"controller": "software"
|
||||
},
|
||||
{
|
||||
"size_gb": "MAX",
|
||||
"raid_level": "0",
|
||||
"controller": "software"
|
||||
}
|
||||
]
|
||||
}
|
||||
|
||||
Current RAID configuration
|
||||
@ -265,7 +270,7 @@ physical disk found on the bare metal node.
|
||||
|
||||
To get the current RAID configuration::
|
||||
|
||||
openstack baremetal --os-baremetal-api-version 1.15 node show <node-uuid-or-name>
|
||||
openstack baremetal node show <node-uuid-or-name>
|
||||
|
||||
Workflow
|
||||
========
|
||||
@ -286,14 +291,14 @@ Workflow
|
||||
openstack baremetal node set <node-uuid-or-name> \
|
||||
--target-raid-config <JSON file containing target RAID configuration>
|
||||
|
||||
The CLI command can accept the input from standard input also:
|
||||
The CLI command can accept the input from standard input also::
|
||||
|
||||
openstack baremetal node set <node-uuid-or-name> \
|
||||
--target-raid-config -
|
||||
|
||||
* Create a JSON file with the RAID clean steps for manual cleaning. Add other
|
||||
clean steps as desired::
|
||||
|
||||
|
||||
[{
|
||||
"interface": "raid",
|
||||
"step": "delete_configuration"
|
||||
@ -347,8 +352,20 @@ There are certain limitations to be aware of:
|
||||
in case of a disk failure.
|
||||
|
||||
* Building RAID will fail if the target disks are already partitioned. Wipe the
|
||||
disks using e.g. the ``erase_device_metadata`` clean step before building
|
||||
RAID.
|
||||
disks using e.g. the ``erase_devices_metadata`` clean step before building
|
||||
RAID::
|
||||
|
||||
[{
|
||||
"interface": "raid",
|
||||
"step": "delete_configuration"
|
||||
},
|
||||
{
|
||||
"interface": "deploy",
|
||||
"step": "erase_devices_metadata"
|
||||
{
|
||||
"interface": "raid",
|
||||
"step": "create_configuration"
|
||||
}]
|
||||
|
||||
* If local boot is going to be used, the final instance image must have the
|
||||
``mdadm`` utility installed and needs to be able to detect software RAID
|
||||
@ -367,7 +384,7 @@ Using RAID in nova flavor for scheduling
|
||||
The operator can specify the `raid_level` capability in nova flavor for node to be selected
|
||||
for scheduling::
|
||||
|
||||
nova flavor-key my-baremetal-flavor set capabilities:raid_level="1+0"
|
||||
openstack flavor set my-baremetal-flavor --property capabilities:raid_level="1+0"
|
||||
|
||||
Developer documentation
|
||||
=======================
|
||||
|