Add documentation for standalone ilo drivers
This commit adds documentation for iLO drivers with standalone ironic. Closes-bug: #1513314 Change-Id: I8d0891176ef59afce006cadc6ae142df427bacfc
This commit is contained in:
parent
e4a9eda382
commit
b0eaea1b1e
@ -251,6 +251,7 @@ Features
|
||||
* Support for out-of-band hardware inspection.
|
||||
* Swiftless deploy for intermediate images
|
||||
* HTTP(S) Based Deploy.
|
||||
* iLO drivers with standalone ironic.
|
||||
|
||||
Requirements
|
||||
~~~~~~~~~~~~
|
||||
@ -320,6 +321,10 @@ HTTP(S) Based Deploy
|
||||
~~~~~~~~~~~~~~~~~~~~
|
||||
Refer to `HTTP(S) Based Deploy Support`_ for more information.
|
||||
|
||||
iLO drivers with standalone ironic
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
Refer to `Support for iLO drivers with Standalone Ironic`_ for more information.
|
||||
|
||||
agent_ilo driver
|
||||
^^^^^^^^^^^^^^^^
|
||||
|
||||
@ -376,6 +381,7 @@ Features
|
||||
* Support for out-of-band hardware inspection.
|
||||
* Swiftless deploy for intermediate images.
|
||||
* HTTP(S) Based Deploy.
|
||||
* iLO drivers with standalone ironic.
|
||||
|
||||
Requirements
|
||||
~~~~~~~~~~~~
|
||||
@ -443,6 +449,10 @@ HTTP(S) Based Deploy
|
||||
~~~~~~~~~~~~~~~~~~~~
|
||||
Refer to `HTTP(S) Based Deploy Support`_ for more information.
|
||||
|
||||
iLO drivers with standalone ironic
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
Refer to `Support for iLO drivers with Standalone Ironic`_ for more information.
|
||||
|
||||
pxe_ilo driver
|
||||
^^^^^^^^^^^^^^
|
||||
|
||||
@ -549,6 +559,10 @@ HTTP(S) Based Deploy
|
||||
~~~~~~~~~~~~~~~~~~~~
|
||||
Refer to `HTTP(S) Based Deploy Support`_ for more information.
|
||||
|
||||
iLO drivers with standalone ironic
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
Refer to `Support for iLO drivers with Standalone Ironic`_ for more information.
|
||||
|
||||
Functionalities across drivers
|
||||
==============================
|
||||
|
||||
@ -828,7 +842,7 @@ HTTP(S) URLs.
|
||||
The HTTP(S) web server can be configured in many ways. For the Apache
|
||||
web server on Ubuntu, refer `here <https://help.ubuntu.com/lts/serverguide/httpd.html>`_.
|
||||
The web server may reside on a different system than the conductor nodes, but its URL
|
||||
must be reachable by the conductor and the baremetal nodes.
|
||||
must be reachable by the conductor and the bare metal nodes.
|
||||
|
||||
Deploy Process
|
||||
~~~~~~~~~~~~~~
|
||||
@ -836,6 +850,34 @@ Deploy Process
|
||||
Refer to `Netboot with HTTP(S) based deploy`_ for partition image boot and refer to
|
||||
`Localboot with HTTP(S) based deploy`_ for whole disk image boot.
|
||||
|
||||
|
||||
Support for iLO drivers with Standalone Ironic
|
||||
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
||||
|
||||
It is possible to use ironic as standalone services without other
|
||||
OpenStack services. iLO drivers can be used in standalone ironic.
|
||||
This feature is referred to as ``iLO drivers with standalone ironic`` in this document and is
|
||||
supported by following drivers:
|
||||
|
||||
* ``pxe_ilo``
|
||||
* ``iscsi_ilo``
|
||||
* ``agent_ilo``
|
||||
|
||||
Configuration
|
||||
~~~~~~~~~~~~~
|
||||
The HTTP(S) web server needs to be configured as described in `HTTP(S) Based Deploy Support`_
|
||||
and `Web server configuration on conductor`_ needs to be configured for hosting
|
||||
intermediate images on conductor as described in
|
||||
`Swiftless deploy for intermediate images`_.
|
||||
|
||||
Deploy Process
|
||||
~~~~~~~~~~~~~~
|
||||
``iscsi_ilo`` supports both netboot and localboot, while ``agent_ilo`` supports
|
||||
only localboot. Refer to `Netboot in standalone ironic`_ and
|
||||
`Localboot in standalone ironic`_ for details of deploy process
|
||||
for netboot and localboot respectively. For ``pxe_ilo``, the deploy process
|
||||
is same as native ``pxe_ipmitool`` driver.
|
||||
|
||||
Deploy Process
|
||||
==============
|
||||
|
||||
@ -1083,3 +1125,80 @@ Localboot with HTTP(S) based deploy
|
||||
Conductor -> Baremetal [label = "Power on the node"];
|
||||
Baremetal -> Baremetal [label = "Boot user image from disk"];
|
||||
}
|
||||
|
||||
Netboot in standalone ironic
|
||||
^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
||||
|
||||
.. seqdiag::
|
||||
:scale: 80
|
||||
|
||||
diagram {
|
||||
Webserver; Conductor; Baremetal; ConductorWebserver; IPA; iLO;
|
||||
activation = none;
|
||||
span_height = 1;
|
||||
edge_length = 250;
|
||||
default_note_color = white;
|
||||
default_fontsize = 14;
|
||||
|
||||
Conductor -> iLO [label = "Powers off the node"];
|
||||
Conductor -> Webserver [label = "Download user image"];
|
||||
Conductor -> Conductor [label = "Creates the FAT32 image containing Ironic API URL and driver name"];
|
||||
Conductor -> ConductorWebserver[label = "Uploads the FAT32 image"];
|
||||
Conductor -> iLO [label = "Attaches the FAT32 image URL as virtual media floppy"];
|
||||
Conductor -> iLO [label = "Attaches the deploy ISO URL as virtual media CDROM"];
|
||||
Conductor -> iLO [label = "Sets one time boot to CDROM"];
|
||||
Conductor -> iLO [label = "Reboot the node"];
|
||||
iLO -> Webserver [label = "Downloads deploy ISO"];
|
||||
Baremetal -> iLO [label = "Boots deploy kernel/ramdisk from iLO virtual media CDROM"];
|
||||
IPA -> Conductor [label = "Lookup node"];
|
||||
Conductor -> IPA [label = "Provides node UUID"];
|
||||
IPA -> Conductor [label = "Heartbeat"];
|
||||
Conductor -> IPA [label = "Exposes the disk over iSCSI"];
|
||||
Conductor -> Conductor [label = "Connects to bare metal's disk over iSCSI and writes image"];
|
||||
Conductor -> Conductor [label = "Generates the boot ISO"];
|
||||
Conductor -> ConductorWebserver [label = "Uploads the boot ISO"];
|
||||
Conductor -> iLO [label = "Attaches boot ISO URL as virtual media CDROM"];
|
||||
Conductor -> iLO [label = "Sets boot device to CDROM"];
|
||||
Conductor -> IPA [label = "Power off the node"];
|
||||
Conductor -> iLO [label = "Power on the node"];
|
||||
iLO -> ConductorWebserver [label = "Downloads boot ISO"];
|
||||
iLO -> Baremetal [label = "Boots the instance kernel/ramdisk from iLO virtual media CDROM"];
|
||||
Baremetal -> Baremetal [label = "Instance kernel finds root partition and continues booting from disk"];
|
||||
}
|
||||
|
||||
Localboot in standalone ironic
|
||||
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
||||
|
||||
.. seqdiag::
|
||||
:scale: 80
|
||||
|
||||
diagram {
|
||||
Webserver; Conductor; Baremetal; ConductorWebserver; IPA; iLO;
|
||||
activation = none;
|
||||
span_height = 1;
|
||||
edge_length = 250;
|
||||
default_note_color = white;
|
||||
default_fontsize = 14;
|
||||
|
||||
Conductor -> iLO [label = "Powers off the node"];
|
||||
Conductor -> Conductor [label = "Creates the FAT32 image containing Ironic API URL and driver name"];
|
||||
Conductor -> ConductorWebserver [label = "Uploads the FAT32 image"];
|
||||
Conductor -> Conductor [label = "Generates URL for FAT32 image"];
|
||||
Conductor -> iLO [label = "Attaches the FAT32 image URL as virtual media floppy"];
|
||||
Conductor -> iLO [label = "Attaches the deploy ISO URL as virtual media CDROM"];
|
||||
Conductor -> iLO [label = "Sets one time boot to CDROM"];
|
||||
Conductor -> iLO [label = "Reboot the node"];
|
||||
iLO -> Webserver [label = "Downloads deploy ISO"];
|
||||
Baremetal -> iLO [label = "Boots deploy kernel/ramdisk from iLO virtual media CDROM"];
|
||||
IPA -> Conductor [label = "Lookup node"];
|
||||
Conductor -> IPA [label = "Provides node UUID"];
|
||||
IPA -> Conductor [label = "Heartbeat"];
|
||||
Conductor -> IPA [label = "Sends the user image HTTP(S) URL"];
|
||||
IPA -> Webserver [label = "Retrieves the user image on bare metal"];
|
||||
IPA -> IPA [label = "Writes user image to disk"];
|
||||
IPA -> Conductor [label = "Heartbeat"];
|
||||
Conductor -> Baremetal [label = "Sets boot device to disk"];
|
||||
Conductor -> IPA [label = "Power off the node"];
|
||||
Conductor -> Baremetal [label = "Power on the node"];
|
||||
Baremetal -> Baremetal [label = "Boot user image from disk"];
|
||||
}
|
||||
|
Loading…
Reference in New Issue
Block a user