Make metrics usable
Metric notifications were hard coded with a value indicating "ipmi" for all hardware types and management interfaces which offer sensor data to be transmitted as a metric notification. Also adds a node_name field to allow processors to leverage the node name as opposed to needing ironic API or database access to construct enough data to make metrics notifications usable. Change-Id: I1116bd5812f3715bd7d6d1bf34df932f81702147
This commit is contained in:
parent
2eceb3c8ab
commit
b5d44d3aaf
@ -2832,8 +2832,7 @@ class ConductorManager(base_manager.BaseConductorManager):
|
||||
message = {'message_id': uuidutils.generate_uuid(),
|
||||
'instance_uuid': instance_uuid,
|
||||
'node_uuid': node_uuid,
|
||||
'timestamp': datetime.datetime.utcnow(),
|
||||
'event_type': 'hardware.ipmi.metrics.update'}
|
||||
'timestamp': datetime.datetime.utcnow()}
|
||||
|
||||
try:
|
||||
lock_purpose = 'getting sensors data'
|
||||
@ -2846,6 +2845,16 @@ class ConductorManager(base_manager.BaseConductorManager):
|
||||
'%s as it is in maintenance mode',
|
||||
task.node.uuid)
|
||||
continue
|
||||
# Add the node name, as the name would be hand for other
|
||||
# notifier plugins
|
||||
message['node_name'] = task.node.name
|
||||
# We should convey the proper hardware type,
|
||||
# which previously was hard coded to ipmi, but other
|
||||
# drivers were transmitting other values under the
|
||||
# guise of ipmi.
|
||||
ev_type = 'hardware.{driver}.metrics'.format(
|
||||
driver=task.node.driver)
|
||||
message['event_type'] = ev_type + '.update'
|
||||
|
||||
task.driver.management.validate(task)
|
||||
sensors_data = task.driver.management.get_sensors_data(
|
||||
@ -2879,7 +2888,7 @@ class ConductorManager(base_manager.BaseConductorManager):
|
||||
self._filter_out_unsupported_types(sensors_data))
|
||||
if message['payload']:
|
||||
self.sensors_notifier.info(
|
||||
context, "hardware.ipmi.metrics", message)
|
||||
context, ev_type, message)
|
||||
finally:
|
||||
# Yield on every iteration
|
||||
eventlet.sleep(0)
|
||||
|
@ -5592,8 +5592,9 @@ class SensorsTestCase(mgr_utils.ServiceSetUpMixin, db_base.DbTestCase):
|
||||
expected_result = {}
|
||||
self.assertEqual(expected_result, actual_result)
|
||||
|
||||
@mock.patch.object(messaging.Notifier, 'info', autospec=True)
|
||||
@mock.patch.object(task_manager, 'acquire')
|
||||
def test_send_sensor_task(self, acquire_mock):
|
||||
def test_send_sensor_task(self, acquire_mock, notifier_mock):
|
||||
nodes = queue.Queue()
|
||||
for i in range(5):
|
||||
nodes.put_nowait(('fake_uuid-%d' % i, 'fake-hardware', '', None))
|
||||
@ -5602,6 +5603,8 @@ class SensorsTestCase(mgr_utils.ServiceSetUpMixin, db_base.DbTestCase):
|
||||
|
||||
task = acquire_mock.return_value.__enter__.return_value
|
||||
task.node.maintenance = False
|
||||
task.node.driver = 'fake'
|
||||
task.node.name = 'fake_node'
|
||||
get_sensors_data_mock = task.driver.management.get_sensors_data
|
||||
validate_mock = task.driver.management.validate
|
||||
get_sensors_data_mock.return_value = 'fake-sensor-data'
|
||||
@ -5609,6 +5612,21 @@ class SensorsTestCase(mgr_utils.ServiceSetUpMixin, db_base.DbTestCase):
|
||||
self.assertEqual(5, acquire_mock.call_count)
|
||||
self.assertEqual(5, validate_mock.call_count)
|
||||
self.assertEqual(5, get_sensors_data_mock.call_count)
|
||||
self.assertEqual(5, notifier_mock.call_count)
|
||||
if six.PY2:
|
||||
# bail out if python2 as matching fails to match the
|
||||
# data structure becasue it requires the order to be consistent
|
||||
# but the mock also records the call dictionary contents in
|
||||
# random order changing with every invocation. :\
|
||||
return
|
||||
n_call = mock.call(mock.ANY, mock.ANY, 'hardware.fake.metrics',
|
||||
{'event_type': 'hardware.fake.metrics.update',
|
||||
'node_name': 'fake_node', 'timestamp': mock.ANY,
|
||||
'message_id': mock.ANY,
|
||||
'payload': 'fake-sensor-data',
|
||||
'node_uuid': mock.ANY, 'instance_uuid': None})
|
||||
notifier_mock.assert_has_calls([n_call, n_call, n_call,
|
||||
n_call, n_call])
|
||||
|
||||
@mock.patch.object(task_manager, 'acquire')
|
||||
def test_send_sensor_task_shutdown(self, acquire_mock):
|
||||
|
@ -0,0 +1,13 @@
|
||||
---
|
||||
features:
|
||||
- |
|
||||
Notification events for metrics data now contains a ``node_name``
|
||||
field to assist operators with relating metrics data being transmitted
|
||||
by the conductor service.
|
||||
fixes:
|
||||
- |
|
||||
Notification event types now include the hardware type name string as
|
||||
opposed to a static string of "ipmi". This allows event processors and
|
||||
operators to understand what the actual notification event data source
|
||||
is as opposed to having to rely upon fingerprints of the data to make
|
||||
such determinations.
|