Merge "Add support for Cisco drivers in Ironic devstack"

This commit is contained in:
Jenkins 2016-04-14 08:14:06 +00:00 committed by Gerrit Code Review
commit ef5ed93b9e

View File

@ -54,12 +54,32 @@ IRONIC_HW_NODE_RAM=${IRONIC_HW_NODE_RAM:-512}
IRONIC_HW_NODE_DISK=${IRONIC_HW_NODE_DISK:-10} IRONIC_HW_NODE_DISK=${IRONIC_HW_NODE_DISK:-10}
IRONIC_HW_EPHEMERAL_DISK=${IRONIC_HW_EPHEMERAL_DISK:-0} IRONIC_HW_EPHEMERAL_DISK=${IRONIC_HW_EPHEMERAL_DISK:-0}
IRONIC_HW_ARCH=${IRONIC_HW_ARCH:-x86_64} IRONIC_HW_ARCH=${IRONIC_HW_ARCH:-x86_64}
# The file is composed of multiple lines, each line includes four field
# separated by white space: IPMI address, MAC address, IPMI username # The file is composed of multiple lines, each line includes fields
# and IPMI password. # separated by white space, in the format:
#
# <BMC address> <MAC address> <BMC username> <BMC password> [<driver specfic fields>]
#
# For example:
# #
# 192.168.110.107 00:1e:67:57:50:4c root otc123 # 192.168.110.107 00:1e:67:57:50:4c root otc123
IRONIC_IPMIINFO_FILE=${IRONIC_IPMIINFO_FILE:-$IRONIC_DATA_DIR/hardware_info} #
# Supported IRONIC_DEPLOY_DRIVERs:
# *_ipmitool:
# <BMC address> <MAC address> <BMC username> <BMC password>
#
# *_cimc:
# <BMC address> <MAC address> <BMC username> <BMC password>
#
# *_ucs:
# <BMC address> <MAC address> <BMC username> <BMC password> <UCS service profile>
#
# IRONIC_IPMIINFO_FILE is deprecated, please use IRONIC_HWINFO_FILE. IRONIC_IPMIINFO_FILE will be removed in Ocata.
IRONIC_IPMIINFO_FILE=${IRONIC_IPMIINFO_FILE:-""}
if [ ! -z "$IRONIC_IPMIINFO_FILE" ]; then
deprecated "IRONIC_IPMIINFO_FILE is deprecated, please switch to IRONIC_HWINFO_FILE. IRONIC_IPMIINFO_FILE will be removed in Ocata."
fi
IRONIC_HWINFO_FILE=${IRONIC_HWINFO_FILE:-${IRONIC_IPMIINFO_FILE:-$IRONIC_DATA_DIR/hardware_info}}
# Set up defaults for functional / integration testing # Set up defaults for functional / integration testing
IRONIC_NODE_UUID=${IRONIC_NODE_UUID:-`uuidgen`} IRONIC_NODE_UUID=${IRONIC_NODE_UUID:-`uuidgen`}
@ -219,6 +239,16 @@ function is_deployed_by_ipmitool {
return 1 return 1
} }
function is_deployed_by_cimc {
[[ -z "${IRONIC_DEPLOY_DRIVER##*_cimc}" ]] && return 0
return 1
}
function is_deployed_by_ucs {
[[ -z "${IRONIC_DEPLOY_DRIVER##*_ucs}" ]] && return 0
return 1
}
function is_deployed_with_ipa_ramdisk { function is_deployed_with_ipa_ramdisk {
is_deployed_by_agent || [[ "$IRONIC_DEPLOY_DRIVER_ISCSI_WITH_IPA" == "True" ]] && return 0 is_deployed_by_agent || [[ "$IRONIC_DEPLOY_DRIVER_ISCSI_WITH_IPA" == "True" ]] && return 0
return 1 return 1
@ -740,9 +770,7 @@ function enroll_nodes {
local ironic_node_disk=$IRONIC_HW_NODE_DISK local ironic_node_disk=$IRONIC_HW_NODE_DISK
local ironic_ephemeral_disk=$IRONIC_HW_EPHEMERAL_DISK local ironic_ephemeral_disk=$IRONIC_HW_EPHEMERAL_DISK
local ironic_node_arch=$IRONIC_HW_ARCH local ironic_node_arch=$IRONIC_HW_ARCH
if [[ -z "${IRONIC_DEPLOY_DRIVER##*_ipmitool}" ]]; then local ironic_hwinfo_file=$IRONIC_HWINFO_FILE
local ironic_hwinfo_file=$IRONIC_IPMIINFO_FILE
fi
fi fi
local total_nodes=0 local total_nodes=0
@ -757,23 +785,33 @@ function enroll_nodes {
vbmc_port=$(echo $hardware_info | awk '{print $2}') vbmc_port=$(echo $hardware_info | awk '{print $2}')
node_options+=" -i ipmi_port=$vbmc_port" node_options+=" -i ipmi_port=$vbmc_port"
fi fi
else
elif is_deployed_by_ipmitool; then
local ipmi_address
ipmi_address=$(echo $hardware_info |awk '{print $1}')
local mac_address
mac_address=$(echo $hardware_info |awk '{print $2}')
local ironic_ipmi_username
ironic_ipmi_username=$(echo $hardware_info |awk '{print $3}')
local ironic_ipmi_passwd
ironic_ipmi_passwd=$(echo $hardware_info |awk '{print $4}')
# Currently we require all hardware platform have same CPU/RAM/DISK info # Currently we require all hardware platform have same CPU/RAM/DISK info
# in future, this can be enhanced to support different type, and then # in future, this can be enhanced to support different type, and then
# we create the bare metal flavor with minimum value # we create the bare metal flavor with minimum value
local node_options="-i ipmi_address=$ipmi_address -i ipmi_password=$ironic_ipmi_passwd\ local bmc_address
-i ipmi_username=$ironic_ipmi_username" bmc_address=$(echo $hardware_info |awk '{print $1}')
node_options+=" -i deploy_kernel=$IRONIC_DEPLOY_KERNEL_ID" local mac_address
mac_address=$(echo $hardware_info |awk '{print $2}')
local bmc_username
bmc_username=$(echo $hardware_info |awk '{print $3}')
local bmc_passwd
bmc_passwd=$(echo $hardware_info |awk '{print $4}')
local node_options="-i deploy_kernel=$IRONIC_DEPLOY_KERNEL_ID"
node_options+=" -i deploy_ramdisk=$IRONIC_DEPLOY_RAMDISK_ID" node_options+=" -i deploy_ramdisk=$IRONIC_DEPLOY_RAMDISK_ID"
if is_deployed_by_ipmitool; then
node_options+=" -i ipmi_address=$bmc_address -i ipmi_password=$bmc_passwd\
-i ipmi_username=$bmc_username"
elif is_deployed_by_cimc; then
node_options+=" -i cimc_address=$bmc_address -i cimc_password=$bmc_passwd\
-i cimc_username=$bmc_username"
elif is_deployed_by_ucs; then
local ucs_service_profile
ucs_service_profile=$(echo $hardware_info |awk '{print $5}')
node_options+=" -i ucs_address=$bmc_address -i ucs_password=$bmc_passwd\
-i ucs_username=$bmc_username -i ucs_service_profile=$ucs_service_profile"
fi
fi fi
# First node created will be used for testing in ironic w/o glance # First node created will be used for testing in ironic w/o glance