Power Synchronization
|
|
=====================
|
|
|
|
Baremetal Power Sync
|
|
====================
|
|
Each Baremetal conductor process runs a periodic task which synchronizes the
|
|
power state of the nodes between its database and the actual hardware. If the
|
|
value of the :oslo.config:option:`conductor.force_power_state_during_sync`
|
|
option is set to ``true`` the power state in the database will be forced on
|
|
the hardware and if it is set to ``false`` the hardware state will be forced
|
|
on the database. If this periodic task is enabled, it runs at an interval
|
|
defined by the :oslo.config:option:`conductor.sync_power_state_interval`
|
|
config option for those nodes which are not in maintenance. The requests sent
|
|
to Baseboard Management Controllers (BMCs) are done with a parallelism
|
|
controlled by :oslo.config:option:`conductor.sync_power_state_workers`.
|
|
The motivation to send out requests to BMCs in parallel is to handle
|
|
misbehaving BMCs which may delay or even block the synchronization otherwise.
|
|
|
|
.. note::
|
|
In deployments with many nodes and IPMI as the configured BMC protocol,
|
|
the default values of a 60 seconds power sync interval and 8 worker
|
|
threads may lead to a high rate of required retries due to client-side UDP
|
|
packet loss (visible via the corresponding warnings in the conductor
|
|
logs). While Ironic automatically retries to get the power status
|
|
for the affected nodes, the failure rate may be reduced by increasing
|
|
the power sync cycle, e.g. to 300 seconds, and/or by reducing the number
|
|
of power sync workers, e.g. to 2. Pleae keep in mind, however, that
|
|
depending on the concrete setup increasing the power sync interval may
|
|
have an impact on other components relying on up-to-date power states.
|
|
|
|
Compute-Baremetal Power Sync
|
|
============================
|
|
Each ``nova-compute`` process in the Compute service runs a periodic task which
|
|
synchronizes the power state of servers between its database and the compute
|
|
driver. If enabled, it runs at an interval defined by the
|
|
`sync_power_state_interval` config option on the ``nova-compute`` process.
|
|
In case of the compute driver being baremetal driver, this sync will happen
|
|
between the databases of the compute and baremetal services. Since the sync
|
|
happens on the ``nova-compute`` process, the state in the compute database
|
|
will be forced on the baremetal database in case of inconsistencies. Hence a
|
|
node which was put down using the compute service API cannot be brought up
|
|
through the baremetal service API since the power sync task will regard the
|
|
compute service's knowledge of the power state as the source of truth. In order
|
|
to get around this disadvantage of the compute-baremetal power sync,
|
|
baremetal service does power state change callbacks to the compute service
|
|
using external events.
|
|
|
|
Power State Change Callbacks to the Compute Service
|
|
---------------------------------------------------
|
|
|
|
Whenever the Baremetal service changes the power state of a node, it can issue
|
|
a notification to the Compute service. The Compute service will consume this
|
|
notification and update the power state of the instance in its database.
|
|
By conveying all the power state changes to the compute service, the baremetal
|
|
service becomes the source of truth thus preventing the compute service from
|
|
forcing wrong power states on the physical instance during the
|
|
compute-baremetal power sync. It also adds the possibility of bringing
|
|
up/down a physical instance through the baremetal service API even if it was
|
|
put down/up through the compute service API.
|
|
|
|
This change requires the :oslo.config:group:`nova` section and the necessary
|
|
authentication options like the :oslo.config:option:`nova.auth_url` to be
|
|
defined in the configuration file of the baremetal service. If it is not
|
|
configured the baremetal service will not be able to send notifications to the
|
|
compute service and it will fall back to the behaviour of the compute service
|
|
forcing power states on the baremetal service during the power sync.
|
|
See :oslo.config:group:`nova` group for more details on the available config
|
|
options.
|
|
|
|
In case of baremetal stand alone deployments where there is no compute service
|
|
running, the :oslo.config:option:`nova.send_power_notifications` config option
|
|
should be set to ``False`` to disable power state change callbacks to the
|
|
compute service.
|
|
|
|
.. note::
|
|
The baremetal service sends notifications to the compute service only if
|
|
the target power state is ``power on`` or ``power off``. Other error
|
|
and ``None`` states will be ignored. In situations where the power state
|
|
change is originally coming from the compute service, the notification
|
|
will still be sent by the baremetal service and it will be a no-op on the
|
|
compute service side with a debug log stating the node is already powering
|
|
on/off.
|
|
|
|
.. note::
|
|
Although an exclusive lock is used when sending notifications to the
|
|
compute service, there can still be a race condition if the
|
|
compute-baremetal power sync happens to happen a nano-second before the
|
|
power state change event is received from the baremetal service in which
|
|
case the power state from compute service's database will be forced on the
|
|
node.
|
|
|
|
.. _power-fault:
|
|
|
|
Power fault and recovery
|
|
========================
|
|
|
|
When `Baremetal Power Sync`_ is enabled, and the Bare Metal service loses
|
|
access to a node (usually because of invalid credentials, BMC issues or
|
|
networking interruptions), the node enters ``maintenance`` mode and its
|
|
``fault`` field is set to ``power failure``. The exact reason is stored in the
|
|
``maintenance_reason`` field.
|
|
|
|
As always with maintenance mode, only a subset of operations will work on such
|
|
nodes, and both the Compute service and the Ironic's native allocation API will
|
|
refuse to pick them. Any in-progress operations will either pause or fail.
|
|
|
|
The conductor responsible for the node will try to recover the connection
|
|
periodically (with the interval configured by the
|
|
:oslo.config:option:`conductor.power_failure_recovery_interval` option). If the
|
|
power sync is successful, the ``fault`` field is unset and the node leaves the
|
|
maintenance mode.
|
|
|
|
.. note::
|
|
This only applies to automatic maintenance mode with the ``fault`` field
|
|
set. Maintenance mode set manually is never left automatically.
|
|
|
|
Alternatively, you can disable maintenance mode yourself once the problem is
|
|
resolved::
|
|
|
|
baremetal node maintenance unset <IRONIC NODE>
|