iDRAC driver
|
||
============
|
||
|
||
Overview
|
||
========
|
||
|
||
The integrated Dell Remote Access Controller (iDRAC_) is an out-of-band
|
||
management platform on Dell EMC servers, and is supported directly by
|
||
the ``idrac`` hardware type. This driver uses the Dell Web Services for
|
||
Management (WSMAN) protocol and the standard Distributed Management Task
|
||
Force (DMTF) Redfish protocol to perform all of its functions.
|
||
|
||
iDRAC_ hardware is also supported by the generic ``ipmi`` and ``redfish``
|
||
hardware types, though with smaller feature sets.
|
||
|
||
Key features of the Dell iDRAC driver include:
|
||
|
||
* Out-of-band node inspection
|
||
* Boot device management and firmware management
|
||
* Power management
|
||
* RAID controller management and RAID volume configuration
|
||
* BIOS settings configuration
|
||
|
||
Ironic Features
|
||
---------------
|
||
|
||
The ``idrac`` hardware type supports the following Ironic interfaces:
|
||
|
||
* `BIOS Interface`_: BIOS management
|
||
* `Inspect Interface`_: Hardware inspection
|
||
* `Management Interface`_: Boot device and firmware management
|
||
* Power Interface: Power management
|
||
* `RAID Interface`_: RAID controller and disk management
|
||
* `Vendor Interface`_: BIOS management (WSMAN) and eject virtual media
|
||
(Redfish)
|
||
|
||
Prerequisites
|
||
-------------
|
||
|
||
The ``idrac`` hardware type requires the ``python-dracclient`` library
|
||
to be installed on the ironic conductor node(s) if an Ironic node is
|
||
configured to use an ``idrac-wsman`` interface implementation, for example::
|
||
|
||
sudo pip install 'python-dracclient>=3.1.0'
|
||
|
||
Additionally, the ``idrac`` hardware type requires the ``sushy`` library
|
||
to be installed on the ironic conductor node(s) if an Ironic node is
|
||
configured to use an ``idrac-redfish`` interface implementation, for example::
|
||
|
||
sudo pip install 'python-dracclient>=3.1.0' 'sushy>=2.0.0'
|
||
|
||
Enabling
|
||
--------
|
||
|
||
The iDRAC driver supports WSMAN for the bios, inspect, management, power,
|
||
raid, and vendor interfaces. In addition, it supports Redfish for
|
||
the bios, inspect, management, power, and raid interfaces. The iDRAC driver
|
||
allows you to mix and match WSMAN and Redfish interfaces.
|
||
|
||
The ``idrac-wsman`` implementation must be enabled to use WSMAN for
|
||
an interface. The ``idrac-redfish`` implementation must be enabled
|
||
to use Redfish for an interface.
|
||
|
||
To enable the ``idrac`` hardware type with the minimum interfaces,
|
||
all using WSMAN, add the following to your ``/etc/ironic/ironic.conf``:
|
||
|
||
.. code-block:: ini
|
||
|
||
[DEFAULT]
|
||
enabled_hardware_types=idrac
|
||
enabled_management_interfaces=idrac-wsman
|
||
enabled_power_interfaces=idrac-wsman
|
||
|
||
To enable all optional features (BIOS, inspection, RAID, and vendor passthru)
|
||
using Redfish where it is supported and WSMAN where not, use the
|
||
following configuration:
|
||
|
||
.. code-block:: ini
|
||
|
||
[DEFAULT]
|
||
enabled_hardware_types=idrac
|
||
enabled_bios_interfaces=idrac-redfish
|
||
enabled_inspect_interfaces=idrac-redfish
|
||
enabled_management_interfaces=idrac-redfish
|
||
enabled_power_interfaces=idrac-redfish
|
||
enabled_raid_interfaces=idrac-redfish
|
||
enabled_vendor_interfaces=idrac-redfish
|
||
|
||
Below is the list of supported interface implementations in priority
|
||
order:
|
||
|
||
================ ===================================================
|
||
Interface Supported Implementations
|
||
================ ===================================================
|
||
``bios`` ``idrac-wsman``, ``idrac-redfish``, ``no-bios``
|
||
``boot`` ``ipxe``, ``pxe``, ``idrac-redfish-virtual-media``
|
||
``console`` ``no-console``
|
||
``deploy`` ``direct``, ``ansible``, ``ramdisk``
|
||
``inspect`` ``idrac-wsman``, ``idrac``, ``idrac-redfish``,
|
||
``inspector``, ``no-inspect``
|
||
``management`` ``idrac-wsman``, ``idrac``, ``idrac-redfish``
|
||
``network`` ``flat``, ``neutron``, ``noop``
|
||
``power`` ``idrac-wsman``, ``idrac``, ``idrac-redfish``
|
||
``raid`` ``idrac-wsman``, ``idrac``, ``idrac-redfish``, ``no-raid``
|
||
``rescue`` ``no-rescue``, ``agent``
|
||
``storage`` ``noop``, ``cinder``, ``external``
|
||
``vendor`` ``idrac-wsman``, ``idrac``, ``idrac-redfish``,
|
||
``no-vendor``
|
||
================ ===================================================
|
||
|
||
.. NOTE::
|
||
``idrac`` is the legacy name of the WSMAN interface. It has been
|
||
deprecated in favor of ``idrac-wsman`` and may be removed in a
|
||
future release.
|
||
|
||
Protocol-specific Properties
|
||
----------------------------
|
||
|
||
The WSMAN and Redfish protocols require different properties to be specified
|
||
in the Ironic node's ``driver_info`` field to communicate with the bare
|
||
metal system's iDRAC.
|
||
|
||
The WSMAN protocol requires the following properties:
|
||
|
||
* ``drac_username``: The WSMAN user name to use when communicating
|
||
with the iDRAC. Usually ``root``.
|
||
* ``drac_password``: The password for the WSMAN user to use when
|
||
communicating with the iDRAC.
|
||
* ``drac_address``: The IP address of the iDRAC.
|
||
|
||
The Redfish protocol requires the following properties:
|
||
|
||
* ``redfish_username``: The Redfish user name to use when
|
||
communicating with the iDRAC. Usually ``root``.
|
||
* ``redfish_password``: The password for the Redfish user to use
|
||
when communicating with the iDRAC.
|
||
* ``redfish_address``: The URL address of the iDRAC. It must include the
|
||
authority portion of the URL, and can optionally include the scheme. If
|
||
the scheme is missing, https is assumed.
|
||
* ``redfish_system_id``: The Redfish ID of the server to be
|
||
managed. This should always be: ``/redfish/v1/Systems/System.Embedded.1``.
|
||
|
||
For other Redfish protocol parameters see :doc:`/admin/drivers/redfish`.
|
||
|
||
If using only interfaces which use WSMAN (``idrac-wsman``), then only
|
||
the WSMAN properties must be supplied. If using only interfaces which
|
||
use Redfish (``idrac-redfish``), then only the Redfish properties must be
|
||
supplied. If using a mix of interfaces, where some use WSMAN and others
|
||
use Redfish, both the WSMAN and Redfish properties must be supplied.
|
||
|
||
Enrolling
|
||
---------
|
||
|
||
The following command enrolls a bare metal node with the ``idrac``
|
||
hardware type using WSMAN for all interfaces:
|
||
|
||
.. code-block:: bash
|
||
|
||
baremetal node create --driver idrac \
|
||
--driver-info drac_username=user \
|
||
--driver-info drac_password=pa$$w0rd \
|
||
--driver-info drac_address=drac.host
|
||
|
||
The following command enrolls a bare metal node with the ``idrac``
|
||
hardware type using Redfish for all interfaces:
|
||
|
||
.. code-block:: bash
|
||
|
||
baremetal node create --driver idrac \
|
||
--driver-info redfish_username=user \
|
||
--driver-info redfish_password=pa$$w0rd \
|
||
--driver-info redfish_address=drac.host \
|
||
--driver-info redfish_system_id=/redfish/v1/Systems/System.Embedded.1 \
|
||
--bios-interface idrac-redfish \
|
||
--inspect-interface idrac-redfish \
|
||
--management-interface idrac-redfish \
|
||
--power-interface idrac-redfish \
|
||
--raid-interface idrac-redfish \
|
||
--vendor-interface idrac-redfish
|
||
|
||
The following command enrolls a bare metal node with the ``idrac``
|
||
hardware type assuming a mix of Redfish and WSMAN interfaces are used:
|
||
|
||
.. code-block:: bash
|
||
|
||
baremetal node create --driver idrac \
|
||
--driver-info drac_username=user \
|
||
--driver-info drac_password=pa$$w0rd
|
||
--driver-info drac_address=drac.host \
|
||
--driver-info redfish_username=user \
|
||
--driver-info redfish_password=pa$$w0rd \
|
||
--driver-info redfish_address=drac.host \
|
||
--driver-info redfish_system_id=/redfish/v1/Systems/System.Embedded.1 \
|
||
--bios-interface idrac-redfish \
|
||
--inspect-interface idrac-redfish \
|
||
--management-interface idrac-redfish \
|
||
--power-interface idrac-redfish
|
||
|
||
.. NOTE::
|
||
If using WSMAN for the management interface, then WSMAN must be used
|
||
for the power interface. The same applies to Redfish. It is currently not
|
||
possible to use Redfish for one and WSMAN for the other.
|
||
|
||
BIOS Interface
|
||
==============
|
||
|
||
The BIOS interface implementations supported by the ``idrac`` hardware type
|
||
allows BIOS to be configured with the standard clean/deploy step approach.
|
||
|
||
Example
|
||
-------
|
||
A clean step to enable ``Virtualization`` and ``SRIOV`` in BIOS of an iDRAC
|
||
BMC would be as follows::
|
||
|
||
{
|
||
"target":"clean",
|
||
"clean_steps": [
|
||
{
|
||
"interface": "bios",
|
||
"step": "apply_configuration",
|
||
"args": {
|
||
"settings": [
|
||
{
|
||
"name": "ProcVirtualization",
|
||
"value": "Enabled"
|
||
},
|
||
{
|
||
"name": "SriovGlobalEnable",
|
||
"value": "Enabled"
|
||
}
|
||
]
|
||
}
|
||
}
|
||
]
|
||
}
|
||
|
||
See the `Known Issues`_ for a known issue with ``factory_reset`` clean step.
|
||
For additional details of BIOS configuration, see :doc:`/admin/bios`.
|
||
|
||
Inspect Interface
|
||
=================
|
||
|
||
The Dell iDRAC out-of-band inspection process catalogs all the same
|
||
attributes of the server as the IPMI driver. Unlike IPMI, it does this
|
||
without requiring the system to be rebooted, or even to be powered on.
|
||
Inspection is performed using the Dell WSMAN or Redfish protocol directly
|
||
without affecting the operation of the system being inspected.
|
||
|
||
The inspection discovers the following properties:
|
||
|
||
* ``cpu_arch``: cpu architecture
|
||
* ``cpus``: number of cpus
|
||
* ``local_gb``: disk size in gigabytes
|
||
* ``memory_mb``: memory size in megabytes
|
||
|
||
Extra capabilities:
|
||
|
||
* ``boot_mode``: UEFI or BIOS boot mode.
|
||
* ``pci_gpu_devices``: number of GPU devices connected to the bare metal.
|
||
|
||
It also creates baremetal ports for each NIC port detected in the system.
|
||
The ``idrac-wsman`` inspect interface discovers which NIC ports are
|
||
configured to PXE boot and sets ``pxe_enabled`` to ``True`` on those ports.
|
||
The ``idrac-redfish`` inspect interface does not currently set ``pxe_enabled``
|
||
on the ports. The user should ensure that ``pxe_enabled`` is set correctly on
|
||
the ports following inspection with the ``idrac-redfish`` inspect interface.
|
||
|
||
Management Interface
|
||
====================
|
||
|
||
The management interface for ``idrac-redfish`` supports:
|
||
|
||
* updating firmware on nodes using a manual cleaning step. See
|
||
:doc:`/admin/drivers/redfish` for more information on firmware update
|
||
support.
|
||
* updating system and getting its inventory using configuration molds. For more
|
||
information see `Import and export configuration`_.
|
||
|
||
|
||
Import and export configuration
|
||
-------------------------------
|
||
|
||
The clean and deploy steps provided in this section allow to configure the
|
||
system and collect the system inventory using configuration mold files.
|
||
|
||
The introduction of this feature in the Wallaby release is experimental.
|
||
|
||
These steps are:
|
||
|
||
* ``export_configuration`` with the ``export_configuration_location`` input
|
||
parameter to export the configuration from the existing system.
|
||
* ``import_configuration`` with the ``import_configuration_location`` input
|
||
parameter to import the existing configuration mold into the system.
|
||
* ``import_export_configuration`` with the ``export_configuration_location``
|
||
and ``import_configuration_location`` input parameters. This step combines
|
||
the previous two steps into one step that first imports existing
|
||
configuration mold into system, then exports the resulting configuration.
|
||
|
||
The input parameters provided include the URL where the configuration mold is
|
||
to be stored after the export, or the reference location for an import. For
|
||
more information on setting up storage and available options see
|
||
`Storage setup`_.
|
||
|
||
Configuration molds are JSON files that contain three top-level sections:
|
||
``bios``, ``raid`` and ``oem``. The following is an example of a configuration
|
||
mold:
|
||
|
||
.. code-block::
|
||
|
||
{
|
||
"bios": {
|
||
"reset": false,
|
||
"settings": [
|
||
{
|
||
"name": "ProcVirtualization",
|
||
"value": "Enabled"
|
||
},
|
||
{
|
||
"name": "MemTest",
|
||
"value": "Disabled"
|
||
}
|
||
]
|
||
}
|
||
"raid": {
|
||
"create_nonroot_volumes": true,
|
||
"create_root_volume": true,
|
||
"delete_existing": false,
|
||
"target_raid_config": {
|
||
"logical_disks": [
|
||
{
|
||
"size_gb": 50,
|
||
"raid_level": "1+0",
|
||
"controller": "RAID.Integrated.1-1",
|
||
"volume_name": "root_volume",
|
||
"is_root_volume": true,
|
||
"physical_disks": [
|
||
"Disk.Bay.0:Encl.Int.0-1:RAID.Integrated.1-1",
|
||
"Disk.Bay.1:Encl.Int.0-1:RAID.Integrated.1-1"
|
||
]
|
||
},
|
||
{
|
||
"size_gb": 100,
|
||
"raid_level": "5",
|
||
"controller": "RAID.Integrated.1-1",
|
||
"volume_name": "data_volume",
|
||
"physical_disks": [
|
||
"Disk.Bay.2:Encl.Int.0-1:RAID.Integrated.1-1",
|
||
"Disk.Bay.3:Encl.Int.0-1:RAID.Integrated.1-1",
|
||
"Disk.Bay.4:Encl.Int.0-1:RAID.Integrated.1-1"
|
||
]
|
||
}
|
||
]
|
||
}
|
||
}
|
||
"oem": {
|
||
"interface": "idrac-redfish",
|
||
"data": {
|
||
"SystemConfiguration": {
|
||
"Model": "PowerEdge R640",
|
||
"ServiceTag": "8CY9Z99",
|
||
"TimeStamp": "Fri Jun 26 08:43:15 2020",
|
||
"Components": [
|
||
{
|
||
[...]
|
||
"FQDD": "NIC.Slot.1-1-1",
|
||
"Attributes": [
|
||
{
|
||
"Name": "BlnkLeds",
|
||
"Value": "15",
|
||
"Set On Import": "True",
|
||
"Comment": "Read and Write"
|
||
},
|
||
{
|
||
"Name": "VirtMacAddr",
|
||
"Value": "00:00:00:00:00:00",
|
||
"Set On Import": "False",
|
||
"Comment": "Read and Write"
|
||
},
|
||
{
|
||
"Name": "VirtualizationMode",
|
||
"Value": "NONE",
|
||
"Set On Import": "True",
|
||
"Comment": "Read and Write"
|
||
},
|
||
[...]
|
||
]
|
||
}
|
||
]
|
||
}
|
||
}
|
||
}
|
||
|
||
Currently, the OEM section is the only section that is supported. The OEM
|
||
section uses the iDRAC Server Configuration Profile (SCP) and can be edited as
|
||
necessary if it complies with the SCP. For more information about SCP and its
|
||
capabilities, see SCP_Reference_Guide_.
|
||
|
||
To replicate the system configuration to that of a similar system, perform the
|
||
following steps:
|
||
|
||
#. Configure a golden, or one to many, system.
|
||
#. Use the ``export_configuration`` step to export the configuration to the
|
||
wanted location.
|
||
#. Adjust the exported configuration mold for other systems to replicate. For
|
||
example, remove sections that do not need to be replicated such as iDRAC
|
||
connection settings. The configuration mold can be accessed directly from
|
||
the storage location.
|
||
#. Import the selected configuration mold into the other systems using the
|
||
``import_configuration`` step.
|
||
|
||
It is not mandatory to use ``export_configuration`` step to create a
|
||
configuration mold. Upload the file to a designated storage location without
|
||
using Ironic if it has been created manually or by other means.
|
||
|
||
Storage setup
|
||
^^^^^^^^^^^^^
|
||
|
||
To start using these steps, configure the storage location. The settings can be
|
||
found in the ``[molds]`` section. Configure the storage type from the
|
||
``[molds]storage`` setting. Currently, ``swift``, which is enabled by default,
|
||
and ``http`` are supported.
|
||
|
||
In the setup input parameters, the complete HTTP URL is used. This requires
|
||
that the containers (for ``swift``) and the directories (for ``http``) are
|
||
created beforehand, and that read/write access is configured accordingly.
|
||
|
||
.. NOTE::
|
||
Use of TLS is strongly advised.
|
||
|
||
This setup configuration allows a user to access these locations outside of
|
||
Ironic to list, create, update, and delete the configuration molds.
|
||
|
||
For more information see `Swift configuration`_ and `HTTP configuration`_.
|
||
|
||
Swift configuration
|
||
~~~~~~~~~~~~~~~~~~~
|
||
|
||
To use Swift with configuration molds,
|
||
|
||
#. Create the containers to be used for configuration mold storage.
|
||
#. For Ironic Swift user that is configured in the ``[swift]`` section add
|
||
read/write access to these containers.
|
||
|
||
HTTP configuration
|
||
~~~~~~~~~~~~~~~~~~
|
||
|
||
To use HTTP server with configuration molds,
|
||
|
||
#. Enable HTTP PUT support.
|
||
#. Create the directory to be used for the configuration mold storage.
|
||
#. Configure read/write access for HTTP Basic access authentication and provide
|
||
user credentials in ``[molds]user`` and ``[molds]password`` fields.
|
||
|
||
The HTTP web server does not support multitenancy and is intended to be used in
|
||
a stand-alone Ironic, or single-tenant OpenStack environment.
|
||
|
||
RAID Interface
|
||
==============
|
||
|
||
See :doc:`/admin/raid` for more information on Ironic RAID support.
|
||
|
||
The following properties are supported by the iDRAC WSMAN and Redfish RAID
|
||
interface implementation:
|
||
|
||
.. NOTE::
|
||
When using ``idrac-redfish`` for RAID interface iDRAC firmware greater than
|
||
4.40.00.00 is required.
|
||
|
||
Mandatory properties
|
||
--------------------
|
||
|
||
* ``size_gb``: Size in gigabytes (integer) for the logical disk. Use ``MAX`` as
|
||
``size_gb`` if this logical disk is supposed to use the rest of the space available.
|
||
* ``raid_level``: RAID level for the logical disk. Valid values are
|
||
``0``, ``1``, ``5``, ``6``, ``1+0``, ``5+0`` and ``6+0``.
|
||
|
||
.. NOTE::
|
||
``JBOD`` and ``2`` are not supported, and will fail with reason: 'Cannot
|
||
calculate spans for RAID level.'
|
||
|
||
Optional properties
|
||
-------------------
|
||
|
||
* ``is_root_volume``: Optional. Specifies whether this disk is a root volume.
|
||
By default, this is ``False``.
|
||
* ``volume_name``: Optional. Name of the volume to be created. If this is not
|
||
specified, it will be auto-generated.
|
||
|
||
Backing physical disk hints
|
||
---------------------------
|
||
|
||
See :doc:`/admin/raid` for more information on backing disk hints.
|
||
|
||
These are machine-independent information. The hints are specified for each
|
||
logical disk to help Ironic find the desired disks for RAID configuration.
|
||
|
||
* ``disk_type``
|
||
* ``interface_type``
|
||
* ``share_physical_disks``
|
||
* ``number_of_physical_disks``
|
||
|
||
Backing physical disks
|
||
----------------------
|
||
|
||
These are Dell RAID controller-specific values and must match the
|
||
names provided by the iDRAC.
|
||
|
||
* ``controller``: Mandatory. The name of the controller to use.
|
||
* ``physical_disks``: Optional. The names of the physical disks to use.
|
||
|
||
.. NOTE::
|
||
``physical_disks`` is a mandatory parameter if the property ``size_gb`` is set to ``MAX``.
|
||
|
||
Examples
|
||
--------
|
||
|
||
Creation of RAID ``1+0`` logical disk with six disks on one controller:
|
||
|
||
.. code-block:: json
|
||
|
||
{ "logical_disks":
|
||
[ { "controller": "RAID.Integrated.1-1",
|
||
"is_root_volume": "True",
|
||
"physical_disks": [
|
||
"Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1",
|
||
"Disk.Bay.1:Enclosure.Internal.0-1:RAID.Integrated.1-1",
|
||
"Disk.Bay.2:Enclosure.Internal.0-1:RAID.Integrated.1-1",
|
||
"Disk.Bay.3:Enclosure.Internal.0-1:RAID.Integrated.1-1",
|
||
"Disk.Bay.4:Enclosure.Internal.0-1:RAID.Integrated.1-1",
|
||
"Disk.Bay.5:Enclosure.Internal.0-1:RAID.Integrated.1-1"],
|
||
"raid_level": "1+0",
|
||
"size_gb": "MAX"}]}
|
||
|
||
|
||
Manual RAID Invocation
|
||
----------------------
|
||
|
||
The following command can be used to delete any existing RAID configuration.
|
||
It deletes all virtual disks/RAID volumes, unassigns all global and dedicated
|
||
hot spare physical disks, and clears foreign configuration:
|
||
|
||
.. code-block:: bash
|
||
|
||
baremetal node clean --clean-steps \
|
||
'[{"interface": "raid", "step": "delete_configuration"}]' ${node_uuid}
|
||
|
||
|
||
The following command shows an example of how to set the target RAID
|
||
configuration:
|
||
|
||
.. code-block:: bash
|
||
|
||
baremetal node set --target-raid-config '{ "logical_disks":
|
||
[ { "controller": "RAID.Integrated.1-1",
|
||
"is_root_volume": true,
|
||
"physical_disks": [
|
||
"Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1",
|
||
"Disk.Bay.1:Enclosure.Internal.0-1:RAID.Integrated.1-1"],
|
||
"raid_level": "0",
|
||
"size_gb": "MAX"}]}' ${node_uuid}
|
||
|
||
|
||
The following command can be used to create a RAID configuration:
|
||
|
||
.. code-block:: bash
|
||
|
||
baremetal node clean --clean-steps \
|
||
'[{"interface": "raid", "step": "create_configuration"}]' <node>
|
||
|
||
|
||
When the physical disk names or controller names are not known, the
|
||
following Python code example shows how the ``python-dracclient`` can
|
||
be used to fetch the information directly from the Dell bare metal:
|
||
|
||
.. code-block:: python
|
||
|
||
import dracclient.client
|
||
|
||
|
||
client = dracclient.client.DRACClient(
|
||
host="192.168.1.1",
|
||
username="root",
|
||
password="calvin")
|
||
controllers = client.list_raid_controllers()
|
||
print(controllers)
|
||
|
||
physical_disks = client.list_physical_disks()
|
||
print(physical_disks)
|
||
|
||
Or using ``sushy`` with Redfish:
|
||
|
||
.. code-block:: python
|
||
|
||
import sushy
|
||
|
||
|
||
client = sushy.Sushy('https://192.168.1.1', username='root', password='calvin', verify=False)
|
||
for s in client.get_system_collection().get_members():
|
||
print("System: %(id)s" % {'id': s.identity})
|
||
for c in system1.storage.get_members():
|
||
print("\tController: %(id)s" % {'id': c.identity})
|
||
for d in c.drives:
|
||
print("\t\tDrive: %(id)s" % {'id': d.identity})
|
||
|
||
Vendor Interface
|
||
================
|
||
|
||
idrac-wsman
|
||
-----------
|
||
|
||
Dell iDRAC BIOS management is available through the Ironic WSMAN vendor
|
||
passthru interface.
|
||
|
||
======================== ============ ======================================
|
||
Method Name HTTP Method Description
|
||
======================== ============ ======================================
|
||
``abandon_bios_config`` ``DELETE`` Abandon a BIOS configuration job.
|
||
``commit_bios_config`` ``POST`` Commit a BIOS configuration job
|
||
submitted through ``set_bios_config``.
|
||
Required argument: ``reboot`` -
|
||
indicates whether a reboot job
|
||
should be automatically created
|
||
with the config job. Returns a
|
||
dictionary containing the ``job_id``
|
||
key with the ID of the newly created
|
||
config job, and the
|
||
``reboot_required`` key indicating
|
||
whether the node needs to be rebooted
|
||
to execute the config job.
|
||
``get_bios_config`` ``GET`` Returns a dictionary containing the
|
||
node's BIOS settings.
|
||
``list_unfinished_jobs`` ``GET`` Returns a dictionary containing
|
||
the key ``unfinished_jobs``; its value
|
||
is a list of dictionaries. Each
|
||
dictionary represents an unfinished
|
||
config job object.
|
||
``set_bios_config`` ``POST`` Change the BIOS configuration on
|
||
a node. Required argument: a
|
||
dictionary of {``AttributeName``:
|
||
``NewValue``}. Returns a dictionary
|
||
containing the ``is_commit_required``
|
||
key indicating whether
|
||
``commit_bios_config`` needs to be
|
||
called to apply the changes and the
|
||
``is_reboot_required`` value
|
||
indicating whether the server must
|
||
also be rebooted. Possible values are
|
||
``true`` and ``false``.
|
||
======================== ============ ======================================
|
||
|
||
|
||
Examples
|
||
^^^^^^^^
|
||
|
||
Get BIOS Config
|
||
~~~~~~~~~~~~~~~
|
||
|
||
.. code-block:: bash
|
||
|
||
baremetal node passthru call --http-method GET <node> get_bios_config
|
||
|
||
Snippet of output showing virtualization enabled:
|
||
|
||
.. code-block:: json
|
||
|
||
{"ProcVirtualization": {
|
||
"current_value": "Enabled",
|
||
"instance_id": "BIOS.Setup.1-1:ProcVirtualization",
|
||
"name": "ProcVirtualization",
|
||
"pending_value": null,
|
||
"possible_values": [
|
||
"Enabled",
|
||
"Disabled"],
|
||
"read_only": false }}
|
||
|
||
There are a number of items to note from the above snippet:
|
||
|
||
* ``name``: this is the name to use in a call to ``set_bios_config``.
|
||
* ``current_value``: the current state of the setting.
|
||
* ``pending_value``: if the value has been set, but not yet committed,
|
||
the new value is shown here. The change can either be committed or
|
||
abandoned.
|
||
* ``possible_values``: shows a list of valid values which can be used
|
||
in a call to ``set_bios_config``.
|
||
* ``read_only``: indicates if the value is capable of being changed.
|
||
|
||
Set BIOS Config
|
||
~~~~~~~~~~~~~~~
|
||
|
||
.. code-block:: bash
|
||
|
||
baremetal node passthru call <node> set_bios_config --arg "name=value"
|
||
|
||
|
||
Walkthrough of perfoming a BIOS configuration change:
|
||
|
||
The following section demonstrates how to change BIOS configuration settings,
|
||
detect that a commit and reboot are required, and act on them accordingly. The
|
||
two properties that are being changed are:
|
||
|
||
* Enable virtualization technology of the processor
|
||
* Globally enable SR-IOV
|
||
|
||
.. code-block:: bash
|
||
|
||
baremetal node passthru call <node> set_bios_config \
|
||
--arg "ProcVirtualization=Enabled" \
|
||
--arg "SriovGlobalEnable=Enabled"
|
||
|
||
This returns a dictionary indicating what actions are required next:
|
||
|
||
.. code-block:: json
|
||
|
||
{
|
||
"is_reboot_required": true,
|
||
"is_commit_required": true
|
||
}
|
||
|
||
|
||
Commit BIOS Changes
|
||
~~~~~~~~~~~~~~~~~~~
|
||
|
||
The next step is to commit the pending change to the BIOS. Note that in this
|
||
example, the ``reboot`` argument is set to ``true``. The response indicates
|
||
that a reboot is no longer required as it has been scheduled automatically
|
||
by the ``commit_bios_config`` call. If the reboot argument is not supplied,
|
||
the job is still created, however it remains in the ``scheduled`` state
|
||
until a reboot is performed. The reboot can be initiated through the
|
||
Ironic power API.
|
||
|
||
.. code-block:: bash
|
||
|
||
baremetal node passthru call <node> commit_bios_config \
|
||
--arg "reboot=true"
|
||
|
||
.. code-block:: json
|
||
|
||
{
|
||
"job_id": "JID_499377293428",
|
||
"reboot_required": false
|
||
}
|
||
|
||
The state of any executing job can be queried:
|
||
|
||
.. code-block:: bash
|
||
|
||
baremetal node passthru call --http-method GET <node> list_unfinished_jobs
|
||
|
||
|
||
.. code-block:: json
|
||
|
||
{"unfinished_jobs":
|
||
[{"status": "Scheduled",
|
||
"name": "ConfigBIOS:BIOS.Setup.1-1",
|
||
"until_time": "TIME_NA",
|
||
"start_time": "TIME_NOW",
|
||
"message": "Task successfully scheduled.",
|
||
"percent_complete": "0",
|
||
"id": "JID_499377293428"}]}
|
||
|
||
|
||
Abandon BIOS Changes
|
||
~~~~~~~~~~~~~~~~~~~~
|
||
|
||
Instead of committing, a pending change can be abandoned:
|
||
|
||
.. code-block:: bash
|
||
|
||
baremetal node passthru call --http-method DELETE <node> abandon_bios_config
|
||
|
||
The abandon command does not provide a response body.
|
||
|
||
|
||
Change Boot Mode
|
||
^^^^^^^^^^^^^^^^
|
||
|
||
The boot mode of the iDRAC can be changed to:
|
||
|
||
* BIOS - Also called legacy or traditional boot mode. The BIOS initializes the
|
||
system’s processors, memory, bus controllers, and I/O devices. After
|
||
initialization is complete, the BIOS passes control to operating system (OS)
|
||
software. The OS loader uses basic services provided by the system BIOS to
|
||
locate and load OS modules into system memory. After booting the system, the
|
||
BIOS and embedded management controllers execute system management
|
||
algorithms, which monitor and optimize the condition of the underlying
|
||
hardware. BIOS configuration settings enable fine-tuning of the
|
||
performance, power management, and reliability features of the system.
|
||
* UEFI - The Unified Extensible Firmware Interface does not change the
|
||
traditional purposes of the system BIOS. To a large extent, a UEFI-compliant
|
||
BIOS performs the same initialization, boot, configuration, and management
|
||
tasks as a traditional BIOS. However, UEFI does change the interfaces and
|
||
data structures the BIOS uses to interact with I/O device firmware and
|
||
operating system software. The primary intent of UEFI is to eliminate
|
||
shortcomings in the traditional BIOS environment, enabling system firmware to
|
||
continue scaling with industry trends.
|
||
|
||
The UEFI boot mode offers:
|
||
|
||
* Improved partitioning scheme for boot media
|
||
* Support for media larger than 2 TB
|
||
* Redundant partition tables
|
||
* Flexible handoff from BIOS to OS
|
||
* Consolidated firmware user interface
|
||
* Enhanced resource allocation for boot device firmware
|
||
|
||
The boot mode can be changed via the WSMAN vendor passthru interface as
|
||
follows:
|
||
|
||
.. code-block:: bash
|
||
|
||
baremetal node passthru call <node> set_bios_config \
|
||
--arg "BootMode=Uefi"
|
||
|
||
baremetal node passthru call <node> commit_bios_config \
|
||
--arg "reboot=true"
|
||
|
||
.. code-block:: bash
|
||
|
||
baremetal node passthru call <node> set_bios_config \
|
||
--arg "BootMode=Bios"
|
||
|
||
baremetal node passthru call <node> commit_bios_config \
|
||
--arg "reboot=true"
|
||
|
||
idrac-redfish
|
||
-------------
|
||
|
||
Through the ``idrac-redfish`` vendor passthru interface these methods are
|
||
available:
|
||
|
||
================ ============ ==============================================
|
||
Method Name HTTP Method Description
|
||
================ ============ ==============================================
|
||
``eject_media`` ``POST`` Eject a virtual media device. If no device is
|
||
provided then all attached devices will be
|
||
ejected. Optional argument: ``boot_device`` -
|
||
the boot device to eject, either, ``cd``,
|
||
``dvd``, ``usb`` or ``floppy``.
|
||
================ ============ ==============================================
|
||
|
||
Known Issues
|
||
============
|
||
|
||
Nodes go into maintenance mode
|
||
------------------------------
|
||
|
||
After some period of time, nodes managed by the ``idrac`` hardware type may go
|
||
into maintenance mode in Ironic. This issue can be worked around by changing
|
||
the Ironic power state poll interval to 70 seconds. See
|
||
``[conductor]sync_power_state_interval`` in ``/etc/ironic/ironic.conf``.
|
||
|
||
PXE reset with "factory_reset" BIOS clean step
|
||
----------------------------------------------
|
||
|
||
When using the ``UEFI boot mode`` with non-default PXE interface, the factory
|
||
reset can cause the PXE interface to be reset to default, which doesn't allow
|
||
the server to PXE boot for any further operations. This can cause a
|
||
``clean_failed`` state on the node or ``deploy_failed`` if you attempt to
|
||
deploy a node after this step. For now, the only solution is for the operator
|
||
to manually restore the PXE settings of the server for it to PXE boot again,
|
||
properly.
|
||
The problem is caused by the fact that with the ``UEFI boot mode``, the
|
||
``idrac`` uses BIOS settings to manage PXE configuration. This is not the case
|
||
with the ``BIOS boot mode`` where the PXE configuration is handled as a
|
||
configuration job on the integrated NIC itself, independently of the BIOS
|
||
settings.
|
||
|
||
.. _Ironic_RAID: https://docs.openstack.org/ironic/latest/admin/raid.html
|
||
.. _iDRAC: https://www.dell.com/idracmanuals
|
||
|
||
WSMAN vendor passthru timeout
|
||
-----------------------------
|
||
|
||
When iDRAC is not ready and executing WSMAN vendor passthru commands, they take
|
||
more time as waiting for iDRAC to become ready again and then time out,
|
||
for example:
|
||
|
||
.. code-block:: bash
|
||
|
||
baremetal node passthru call --http-method GET \
|
||
aed58dca-1b25-409a-a32f-3a817d59e1e0 list_unfinished_jobs
|
||
Timed out waiting for a reply to message ID 547ce7995342418c99ef1ea4a0054572 (HTTP 500)
|
||
|
||
To avoid this need to increase timeout for messaging in ``/etc/ironic/ironic.conf``
|
||
and restart Ironic API service.
|
||
|
||
.. code-block:: ini
|
||
|
||
[DEFAULT]
|
||
rpc_response_timeout = 600
|
||
|
||
Timeout when powering off
|
||
-------------------------
|
||
|
||
Some servers might be slow when soft powering off and time out. The default retry count
|
||
is 6, resulting in 30 seconds timeout (the default retry interval set by
|
||
``post_deploy_get_power_state_retry_interval`` is 5 seconds).
|
||
To resolve this issue, increase the timeout to 90 seconds by setting the retry count to
|
||
18 as follows:
|
||
|
||
.. code-block:: ini
|
||
|
||
[agent]
|
||
post_deploy_get_power_state_retries = 18
|
||
|
||
Unable to mount remote share with iDRAC firmware before 4.40.40.00
|
||
------------------------------------------------------------------
|
||
|
||
When using iDRAC firmware 4.40.00.00 and consecutive versions before 4.40.40.00
|
||
with virtual media boot and new Virtual Console plug-in type eHTML5, there is
|
||
an error: "Unable to mount remote share". This is a known issue that is fixed
|
||
in 4.40.40.00 iDRAC firmware release. If cannot upgrade, then adjust settings
|
||
in iDRAC to use plug-in type HTML5. In iDRAC web UI go to Configuration ->
|
||
Virtual Console and select Plug-in Type to HTML5.
|
||
|
||
During upgrade to 4.40.00.00 or newer iDRAC firmware eHTML5 is automatically
|
||
selected if default plug-in type has been used and never changed. Systems that
|
||
have plug-in type changed will keep selected plug-in type after iDRAC firmware
|
||
upgrade.
|
||
|
||
.. _SCP_Reference_Guide: http://downloads.dell.com/manuals/common/dellemc-server-config-profile-refguide.pdf
|