docs: Reword bare metal registration section
A few long sentences are split up. YAML indentation is fixed. Change-Id: I60098522e08f0d463d0300beac64476f7b1488e6
This commit is contained in:
parent
d42523cabb
commit
039fa30cef
@ -16,58 +16,61 @@ node. This behavior can be changed by overriding the variable
|
||||
Register
|
||||
--------
|
||||
|
||||
This is an experimental workflow and acts as an alternative to enrolling nodes
|
||||
through inspection where nodes can be registered in Ironic via kayobe given these
|
||||
nodes are defined in the Kayobe inventory, an example hosts file for group r1 is below:
|
||||
This is an experimental workflow which acts as an alternative to enrolling
|
||||
nodes through inspection. Bare metal compute nodes can be registered in Ironic
|
||||
via Kayobe if defined in the Kayobe inventory. An example hosts file for group
|
||||
r1 is below:
|
||||
|
||||
.. code-block:: ini
|
||||
|
||||
[r1]
|
||||
hv100 ipmi_address=1.2.3.4
|
||||
...
|
||||
[r1]
|
||||
hv100 ipmi_address=1.2.3.4
|
||||
...
|
||||
|
||||
[baremetal-compute:children]
|
||||
r1
|
||||
[baremetal-compute:children]
|
||||
r1
|
||||
|
||||
You should also define a group_vars file for this group containing the Ironic
|
||||
vars, this could be in ``etc/kayobe/inventory/group_vars/r1/ironic_vars`` or
|
||||
in the environment you are using.
|
||||
You should also define a ``group_vars`` file for this group containing the
|
||||
Ironic variables, this could be in
|
||||
``etc/kayobe/inventory/group_vars/r1/ironic_vars`` or in the environment you
|
||||
are using.
|
||||
|
||||
.. code-block:: yaml
|
||||
|
||||
ironic_driver: redfish
|
||||
ironic_driver: redfish
|
||||
|
||||
ironic_driver_info:
|
||||
redfish_system_id: "{{ ironic_redfish_system_id }}"
|
||||
redfish_address: "{{ ironic_redfish_address }}"
|
||||
redfish_username: "{{ ironic_redfish_username }}"
|
||||
redfish_password: "{{ ironic_redfish_password }}"
|
||||
redfish_verify_ca: "{{ ironic_redfish_verify_ca }}"
|
||||
ipmi_address: "{{ ipmi_address }}"
|
||||
ironic_driver_info:
|
||||
redfish_system_id: "{{ ironic_redfish_system_id }}"
|
||||
redfish_address: "{{ ironic_redfish_address }}"
|
||||
redfish_username: "{{ ironic_redfish_username }}"
|
||||
redfish_password: "{{ ironic_redfish_password }}"
|
||||
redfish_verify_ca: "{{ ironic_redfish_verify_ca }}"
|
||||
ipmi_address: "{{ ipmi_address }}"
|
||||
|
||||
ironic_properties:
|
||||
capabilities: "{{ ironic_capabilities }}"
|
||||
ironic_properties:
|
||||
capabilities: "{{ ironic_capabilities }}"
|
||||
|
||||
ironic_resource_class: "example_resouce_class"
|
||||
ironic_redfish_system_id: "/redfish/v1/Systems/System.Embedded.1"
|
||||
ironic_redfish_verify_ca: "{{ inspector_rule_var_redfish_verify_ca }}"
|
||||
ironic_redfish_address: "{{ ipmi_address }}"
|
||||
ironic_redfish_username: "{{ inspector_redfish_username }}"
|
||||
ironic_redfish_password: "{{ inspector_redfish_password }}"
|
||||
ironic_capabilities: "boot_option:local,boot_mode:uefi"
|
||||
ironic_resource_class: "example_resource_class"
|
||||
ironic_redfish_system_id: "/redfish/v1/Systems/System.Embedded.1"
|
||||
ironic_redfish_verify_ca: "{{ inspector_rule_var_redfish_verify_ca }}"
|
||||
ironic_redfish_address: "{{ ipmi_address }}"
|
||||
ironic_redfish_username: "{{ inspector_redfish_username }}"
|
||||
ironic_redfish_password: "{{ inspector_redfish_password }}"
|
||||
ironic_capabilities: "boot_option:local,boot_mode:uefi"
|
||||
|
||||
It's essential that the Ironic username and password match the BMC username
|
||||
and password for your nodes, if the username and password combination is
|
||||
not the same for the entire group you will need to adjust your configuration
|
||||
It is essential that the Ironic username and password match the BMC username
|
||||
and password for your nodes. If the username and password combination is not
|
||||
the same for the entire group you will need to adjust your configuration
|
||||
accordingly. The IPMI address should also match the BMC address for your node.
|
||||
|
||||
Once this has been completed you can begin enrolling the Ironic nodes::
|
||||
|
||||
(kayobe) $ kayobe baremetal compute register
|
||||
|
||||
Inspector is not used to discover nodes and no node inspection will take place on
|
||||
enrollment, nodes will automatically be placed into ``manageable`` state. To inspect,
|
||||
you should use ``kayobe baremetal compute inspect`` following enrollment.
|
||||
Inspector is not used to discover nodes and no node inspection will take place
|
||||
on enrollment, nodes will automatically be placed into ``manageable`` state. To
|
||||
inspect, you should use ``kayobe baremetal compute inspect`` following
|
||||
enrollment.
|
||||
|
||||