openstack-ansible-os_octavia/templates
Jesse Pretorius 4294f6016b Reduce init restart/kill times
The systemd unit 'TimeoutSec' value which controls the time
between sending a SIGTERM signal and a SIGKILL signal when
stopping or restarting the service has been reduced from 300
seconds to 120 seconds. This provides 2 minutes for long-lived
sessions to drain while preventing new ones from starting
before a restart or a stop.

The 'RestartSec' value which controls the time between the
service stop and start when restarting has been reduced from
150 seconds to 2 seconds to make the restart happen faster.

These values can be adjusted by using the *_init_config_overrides
variables which use the config_template task to change template
defaults.

Change-Id: I707b764758c7cc04445b4f0d6efebff8a7a7a81c
2017-04-27 16:04:43 +01:00
..
octavia-systemd-init.j2 Reduce init restart/kill times 2017-04-27 16:04:43 +01:00
octavia-systemd-tmpfiles.j2 Octavia role hacking 2017-03-01 12:48:12 -05:00
octavia.conf.j2 Merge "Remove verbose option" 2017-03-30 22:17:03 +00:00