#!/bin/bash
|
|
set -ex
|
|
export LC_ALL=C
|
|
: "${K8S_HOST_NETWORK:=0}"
|
|
: "${MON_KEYRING:=/etc/ceph/${CLUSTER}.mon.keyring}"
|
|
: "${ADMIN_KEYRING:=/etc/ceph/${CLUSTER}.client.admin.keyring}"
|
|
: "${MDS_BOOTSTRAP_KEYRING:=/var/lib/ceph/bootstrap-mds/${CLUSTER}.keyring}"
|
|
: "${OSD_BOOTSTRAP_KEYRING:=/var/lib/ceph/bootstrap-osd/${CLUSTER}.keyring}"
|
|
: "${CEPH_CONF:="/etc/ceph/${CLUSTER}.conf"}"
|
|
|
|
if [[ ! -e ${CEPH_CONF}.template ]]; then
|
|
echo "ERROR- ${CEPH_CONF}.template must exist; get it from your existing mon"
|
|
exit 1
|
|
else
|
|
ENDPOINT=$(kubectl get endpoints ceph-mon-discovery -n ${NAMESPACE} -o json | awk -F'"' -v port=${MON_PORT} \
|
|
-v version=v1 -v msgr_version=v2 \
|
|
-v msgr2_port=${MON_PORT_V2} \
|
|
'/"ip"/{print "["version":"$4":"port"/"0","msgr_version":"$4":"msgr2_port"/"0"]"}' | paste -sd',')
|
|
if [[ "${ENDPOINT}" == "" ]]; then
|
|
/bin/sh -c -e "cat ${CEPH_CONF}.template | tee ${CEPH_CONF}" || true
|
|
else
|
|
/bin/sh -c -e "cat ${CEPH_CONF}.template | sed 's#mon_host.*#mon_host = ${ENDPOINT}#g' | tee ${CEPH_CONF}" || true
|
|
fi
|
|
fi
|
|
|
|
if [[ -z "$CEPH_PUBLIC_NETWORK" ]]; then
|
|
echo "ERROR- CEPH_PUBLIC_NETWORK must be defined as the name of the network for the OSDs"
|
|
exit 1
|
|
fi
|
|
|
|
if [[ -z "$MON_IP" ]]; then
|
|
echo "ERROR- MON_IP must be defined as the IP address of the monitor"
|
|
exit 1
|
|
fi
|
|
|
|
if [[ ${K8S_HOST_NETWORK} -eq 0 ]]; then
|
|
MON_NAME=${POD_NAME}
|
|
else
|
|
MON_NAME=${NODE_NAME}
|
|
fi
|
|
MON_DATA_DIR="/var/lib/ceph/mon/${CLUSTER}-${MON_NAME}"
|
|
MONMAP="/etc/ceph/monmap-${CLUSTER}"
|
|
|
|
# Make the monitor directory
|
|
/bin/sh -c "mkdir -p \"${MON_DATA_DIR}\""
|
|
|
|
function get_mon_config {
|
|
# Get fsid from ceph.conf
|
|
local fsid=$(ceph-conf --lookup fsid -c /etc/ceph/${CLUSTER}.conf)
|
|
|
|
timeout=10
|
|
MONMAP_ADD=""
|
|
|
|
while [[ -z "${MONMAP_ADD// }" && "${timeout}" -gt 0 ]]; do
|
|
# Get the ceph mon pods (name and IP) from the Kubernetes API. Formatted as a set of monmap params
|
|
if [[ ${K8S_HOST_NETWORK} -eq 0 ]]; then
|
|
MONMAP_ADD=$(kubectl get pods --namespace=${NAMESPACE} ${KUBECTL_PARAM} -o template --template="{{`{{range .items}}`}}{{`{{if .status.podIP}}`}}--addv {{`{{.metadata.name}}`}} [v1:{{`{{.status.podIP}}`}}:${MON_PORT},v2:{{`{{.status.podIP}}`}}:${MON_PORT_V2}] {{`{{end}}`}} {{`{{end}}`}}")
|
|
else
|
|
MONMAP_ADD=$(kubectl get pods --namespace=${NAMESPACE} ${KUBECTL_PARAM} -o template --template="{{`{{range .items}}`}}{{`{{if .status.podIP}}`}}--addv {{`{{.spec.nodeName}}`}} [v1:{{`{{.status.podIP}}`}}:${MON_PORT},v2:{{`{{.status.podIP}}`}}:${MON_PORT_V2}] {{`{{end}}`}} {{`{{end}}`}}")
|
|
fi
|
|
(( timeout-- ))
|
|
sleep 1
|
|
done
|
|
|
|
if [[ -z "${MONMAP_ADD// }" ]]; then
|
|
exit 1
|
|
fi
|
|
|
|
# Create a monmap with the Pod Names and IP
|
|
monmaptool --create ${MONMAP_ADD} --fsid ${fsid} ${MONMAP} --clobber
|
|
}
|
|
|
|
get_mon_config
|
|
|
|
# If we don't have a monitor keyring, this is a new monitor
|
|
if [ ! -e "${MON_DATA_DIR}/keyring" ]; then
|
|
if [ ! -e ${MON_KEYRING}.seed ]; then
|
|
echo "ERROR- ${MON_KEYRING}.seed must exist. You can extract it from your current monitor by running 'ceph auth get mon. -o ${MON_KEYRING}' or use a KV Store"
|
|
exit 1
|
|
else
|
|
cp -vf ${MON_KEYRING}.seed ${MON_KEYRING}
|
|
fi
|
|
|
|
if [ ! -e ${MONMAP} ]; then
|
|
echo "ERROR- ${MONMAP} must exist. You can extract it from your current monitor by running 'ceph mon getmap -o ${MONMAP}' or use a KV Store"
|
|
exit 1
|
|
fi
|
|
|
|
# Testing if it's not the first monitor, if one key doesn't exist we assume none of them exist
|
|
for KEYRING in ${OSD_BOOTSTRAP_KEYRING} ${MDS_BOOTSTRAP_KEYRING} ${ADMIN_KEYRING}; do
|
|
ceph-authtool ${MON_KEYRING} --import-keyring ${KEYRING}
|
|
done
|
|
|
|
# Prepare the monitor daemon's directory with the map and keyring
|
|
ceph-mon --setuser ceph --setgroup ceph --cluster "${CLUSTER}" --mkfs -i ${MON_NAME} --inject-monmap ${MONMAP} --keyring ${MON_KEYRING} --mon-data "${MON_DATA_DIR}"
|
|
else
|
|
echo "Trying to get the most recent monmap..."
|
|
# Ignore when we timeout, in most cases that means the cluster has no quorum or
|
|
# no mons are up and running yet
|
|
timeout 5 ceph --cluster "${CLUSTER}" mon getmap -o ${MONMAP} || true
|
|
ceph-mon --setuser ceph --setgroup ceph --cluster "${CLUSTER}" -i ${MON_NAME} --inject-monmap ${MONMAP} --keyring ${MON_KEYRING} --mon-data "${MON_DATA_DIR}"
|
|
timeout 7 ceph --cluster "${CLUSTER}" mon add "${MON_NAME}" "${MON_IP}:${MON_PORT_V2}" || true
|
|
fi
|
|
|
|
# start MON
|
|
exec /usr/bin/ceph-mon \
|
|
--cluster "${CLUSTER}" \
|
|
--setuser "ceph" \
|
|
--setgroup "ceph" \
|
|
-d \
|
|
-i ${MON_NAME} \
|
|
--mon-data "${MON_DATA_DIR}" \
|
|