9b46e06062
Story: 2003851 Task: 26644 Change-Id: I425dac241cbf454d91c644e7d2ef65625f70e01c
497 lines
17 KiB
Smarty
497 lines
17 KiB
Smarty
#!/bin/bash
|
|
|
|
{{/*
|
|
Licensed under the Apache License, Version 2.0 (the "License");
|
|
you may not use this file except in compliance with the License.
|
|
You may obtain a copy of the License at
|
|
|
|
http://www.apache.org/licenses/LICENSE-2.0
|
|
|
|
Unless required by applicable law or agreed to in writing, software
|
|
distributed under the License is distributed on an "AS IS" BASIS,
|
|
WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
|
|
See the License for the specific language governing permissions and
|
|
limitations under the License.
|
|
*/}}
|
|
|
|
set -ex
|
|
|
|
OVS_SOCKET=/run/openvswitch/db.sock
|
|
chown neutron: ${OVS_SOCKET}
|
|
|
|
# This enables the usage of 'ovs-appctl' from neutron pod.
|
|
OVS_PID=$(cat /run/openvswitch/ovs-vswitchd.pid)
|
|
OVS_CTL=/run/openvswitch/ovs-vswitchd.${OVS_PID}.ctl
|
|
chown neutron: ${OVS_CTL}
|
|
|
|
function get_dpdk_config_value {
|
|
values=$1
|
|
filter=$2
|
|
value=$(echo ${values} | jq -r ${filter})
|
|
if [[ "${value}" == "null" ]]; then
|
|
echo ""
|
|
else
|
|
echo "${value}"
|
|
fi
|
|
}
|
|
|
|
|
|
DPDK_CONFIG_FILE=/tmp/dpdk.conf
|
|
DPDK_CONFIG=""
|
|
DPDK_ENABLED=false
|
|
if [ -f ${DPDK_CONFIG_FILE} ]; then
|
|
DPDK_CONFIG=$(cat ${DPDK_CONFIG_FILE})
|
|
if [[ $(get_dpdk_config_value ${DPDK_CONFIG} '.enabled') == "true" ]]; then
|
|
DPDK_ENABLED=true
|
|
fi
|
|
fi
|
|
|
|
function bind_nic {
|
|
echo $2 > /sys/bus/pci/devices/$1/driver_override
|
|
echo $1 > /sys/bus/pci/drivers/$2/bind
|
|
}
|
|
|
|
function unbind_nic {
|
|
echo $1 > /sys/bus/pci/drivers/$2/unbind
|
|
echo > /sys/bus/pci/devices/$1/driver_override
|
|
}
|
|
|
|
function get_name_by_pci_id {
|
|
path=$(find /sys/bus/pci/devices/$1/ -name net)
|
|
if [ -n "${path}" ] ; then
|
|
echo $(ls -1 $path/)
|
|
fi
|
|
}
|
|
|
|
function get_ip_address_from_interface {
|
|
local interface=$1
|
|
local ip=$(ip -4 -o addr s "${interface}" | awk '{ print $4; exit }' | awk -F '/' 'NR==1 {print $1}')
|
|
if [ -z "${ip}" ] ; then
|
|
exit 1
|
|
fi
|
|
echo ${ip}
|
|
}
|
|
|
|
function get_ip_prefix_from_interface {
|
|
local interface=$1
|
|
local prefix=$(ip -4 -o addr s "${interface}" | awk '{ print $4; exit }' | awk -F '/' 'NR==1 {print $2}')
|
|
if [ -z "${prefix}" ] ; then
|
|
exit 1
|
|
fi
|
|
echo ${prefix}
|
|
}
|
|
|
|
function migrate_ip {
|
|
pci_id=$1
|
|
bridge_name=$2
|
|
|
|
local src_nic=$(get_name_by_pci_id ${pci_id})
|
|
if [ -n "${src_nic}" ] ; then
|
|
bridge_exists=$(ip a s "${bridge_name}" | grep "${bridge_name}" | cut -f2 -d':' 2> /dev/null)
|
|
if [ -z "${bridge_exists}" ] ; then
|
|
echo "Bridge "${bridge_name}" does not exist. Creating it on demand."
|
|
init_ovs_dpdk_bridge "${bridge_name}"
|
|
fi
|
|
|
|
migrate_ip_from_nic ${src_nic} ${bridge_name}
|
|
fi
|
|
}
|
|
|
|
function migrate_ip_from_nic {
|
|
src_nic=$1
|
|
bridge_name=$2
|
|
|
|
# Enabling explicit error handling: We must avoid to lose the IP
|
|
# address in the migration process. Hence, on every error, we
|
|
# attempt to assign the IP back to the original NIC and exit.
|
|
set +e
|
|
|
|
ip=$(get_ip_address_from_interface ${src_nic})
|
|
prefix=$(get_ip_prefix_from_interface ${src_nic})
|
|
|
|
bridge_ip=$(get_ip_address_from_interface "${bridge_name}")
|
|
bridge_prefix=$(get_ip_prefix_from_interface "${bridge_name}")
|
|
|
|
ip link set ${bridge_name} up
|
|
|
|
if [[ -n "${ip}" && -n "${prefix}" ]]; then
|
|
ip addr flush dev ${src_nic}
|
|
if [ $? -ne 0 ] ; then
|
|
ip addr add ${ip}/${prefix} dev ${src_nic}
|
|
echo "Error while flushing IP from ${src_nic}."
|
|
exit 1
|
|
fi
|
|
|
|
ip addr add ${ip}/${prefix} dev "${bridge_name}"
|
|
if [ $? -ne 0 ] ; then
|
|
echo "Error assigning IP to bridge "${bridge_name}"."
|
|
ip addr add ${ip}/${prefix} dev ${src_nic}
|
|
exit 1
|
|
fi
|
|
elif [[ -n "${bridge_ip}" && -n "${bridge_prefix}" ]]; then
|
|
echo "Bridge '${bridge_name}' already has IP assigned. Keeping the same:: IP:[${bridge_ip}]; Prefix:[${bridge_prefix}]..."
|
|
elif [[ -z "${bridge_ip}" && -z "${ip}" ]]; then
|
|
echo "Interface and bridge have no ips configured. Leaving as is."
|
|
else
|
|
echo "Interface ${name} has invalid IP address. IP:[${ip}]; Prefix:[${prefix}]..."
|
|
exit 1
|
|
fi
|
|
|
|
set -e
|
|
}
|
|
|
|
function get_pf_or_vf_pci {
|
|
dpdk_pci_id=${1}
|
|
vf_index=${2}
|
|
|
|
if [ -n "$vf_index" ]
|
|
then
|
|
iface=$(get_name_by_pci_id "${dpdk_pci_id}")
|
|
sysfs_numvfs_path="/sys/class/net/${iface}/device/sriov_numvfs"
|
|
if [[ -f /sys/class/net/${iface}/device/sriov_numvfs &&
|
|
"$(cat /sys/class/net/${iface}/device/sriov_numvfs)" -ne "0" &&
|
|
-e /sys/class/net/${iface}/device/virtfn${vf_index} ]]
|
|
then
|
|
dpdk_pci_id=$(ls -la /sys/class/net/${iface}/device/virtfn${vf_index})
|
|
dpdk_pci_id=${dpdk_pci_id#*"../"}
|
|
else
|
|
echo "Error fetching the VF PCI for PF: ["${iface}", "${dpdk_pci_id}"] and VF-Index: ${vf_index}."
|
|
exit 1
|
|
fi
|
|
fi
|
|
}
|
|
|
|
function bind_dpdk_nic {
|
|
target_driver=${1}
|
|
pci_id=${2}
|
|
|
|
current_driver="$(get_driver_by_address "${pci_id}" )"
|
|
if [ "$current_driver" != "$target_driver" ]; then
|
|
if [ "$current_driver" != "" ]; then
|
|
unbind_nic "${pci_id}" ${current_driver}
|
|
fi
|
|
bind_nic "${pci_id}" ${target_driver}
|
|
fi
|
|
}
|
|
|
|
function process_dpdk_nics {
|
|
target_driver=$(get_dpdk_config_value ${DPDK_CONFIG} '.driver')
|
|
# loop over all nics
|
|
echo $DPDK_CONFIG | jq -r -c '.nics[]' | \
|
|
while IFS= read -r nic; do
|
|
local port_name=$(get_dpdk_config_value ${nic} '.name')
|
|
local pci_id=$(get_dpdk_config_value ${nic} '.pci_id')
|
|
local bridge=$(get_dpdk_config_value ${nic} '.bridge')
|
|
local vf_index=$(get_dpdk_config_value ${nic} '.vf_index')
|
|
|
|
if [[ $(get_dpdk_config_value ${nic} '.migrate_ip') == true ]] ; then
|
|
migrate_ip "${pci_id}" "${bridge}"
|
|
fi
|
|
|
|
iface=$(get_name_by_pci_id "${pci_id}")
|
|
|
|
if [ -n "${iface}" ]; then
|
|
ip link set ${iface} promisc on
|
|
if [ -n "${vf_index}" ]; then
|
|
vf_string="vf ${vf_index}"
|
|
ip link set ${iface} ${vf_string} trust on
|
|
|
|
# NOTE: To ensure proper toggle of spoofchk,
|
|
# turn it on then off.
|
|
ip link set ${iface} ${vf_string} spoofchk on
|
|
ip link set ${iface} ${vf_string} spoofchk off
|
|
fi
|
|
fi
|
|
|
|
# Fetch the PCI to be bound to DPDK driver.
|
|
# In case VF Index is configured then PCI of that particular VF
|
|
# is bound to DPDK, otherwise PF PCI is bound to DPDK.
|
|
get_pf_or_vf_pci "${pci_id}" "${vf_index}"
|
|
|
|
bind_dpdk_nic ${target_driver} "${dpdk_pci_id}"
|
|
|
|
dpdk_options=""
|
|
ofport_request=$(get_dpdk_config_value ${nic} '.ofport_request')
|
|
if [ -n "${ofport_request}" ]; then
|
|
dpdk_options+='ofport_request=${ofport_request} '
|
|
fi
|
|
n_rxq=$(get_dpdk_config_value ${nic} '.n_rxq')
|
|
if [ -n "${n_rxq}" ]; then
|
|
dpdk_options+='options:n_rxq=${n_rxq} '
|
|
fi
|
|
n_txq=$(get_dpdk_config_value ${nic} '.n_txq')
|
|
if [ -n "${n_txq}" ]; then
|
|
dpdk_options+='options:n_txq=${n_txq} '
|
|
fi
|
|
pmd_rxq_affinity=$(get_dpdk_config_value ${nic} '.pmd_rxq_affinity')
|
|
if [ -n "${pmd_rxq_affinity}" ]; then
|
|
dpdk_options+='other_config:pmd-rxq-affinity=${pmd_rxq_affinity} '
|
|
fi
|
|
mtu=$(get_dpdk_config_value ${nic} '.mtu')
|
|
if [ -n "${mtu}" ]; then
|
|
dpdk_options+='mtu_request=${mtu} '
|
|
fi
|
|
n_rxq_size=$(get_dpdk_config_value ${nic} '.n_rxq_size')
|
|
if [ -n "${n_rxq_size}" ]; then
|
|
dpdk_options+='options:n_rxq_desc=${n_rxq_size} '
|
|
fi
|
|
n_txq_size=$(get_dpdk_config_value ${nic} '.n_txq_size')
|
|
if [ -n "${n_txq_size}" ]; then
|
|
dpdk_options+='options:n_txq_desc=${n_txq_size} '
|
|
fi
|
|
vhost_iommu_support=$(get_dpdk_config_value ${nic} '.vhost-iommu-support')
|
|
if [ -n "${vhost_iommu_support}" ]; then
|
|
dpdk_options+='options:vhost-iommu-support=${vhost_iommu_support} '
|
|
fi
|
|
|
|
ovs-vsctl --db=unix:${OVS_SOCKET} --may-exist add-port ${bridge} ${port_name} \
|
|
-- set Interface ${port_name} type=dpdk options:dpdk-devargs=${pci_id} ${dpdk_options}
|
|
|
|
done
|
|
}
|
|
|
|
function process_dpdk_bonds {
|
|
target_driver=$(get_dpdk_config_value ${DPDK_CONFIG} '.driver')
|
|
# loop over all bonds
|
|
echo $DPDK_CONFIG | jq -r -c '.bonds[]' > /tmp/bonds_array
|
|
while IFS= read -r bond; do
|
|
local bond_name=$(get_dpdk_config_value ${bond} '.name')
|
|
local dpdk_bridge=$(get_dpdk_config_value ${bond} '.bridge')
|
|
local migrate_ip=$(get_dpdk_config_value ${bond} '.migrate_ip')
|
|
local mtu=$(get_dpdk_config_value ${bond} '.mtu')
|
|
local n_rxq=$(get_dpdk_config_value ${bond} '.n_rxq')
|
|
local n_txq=$(get_dpdk_config_value ${bond} '.n_txq')
|
|
local ofport_request=$(get_dpdk_config_value ${bond} '.ofport_request')
|
|
local n_rxq_size=$(get_dpdk_config_value ${bond} '.n_rxq_size')
|
|
local n_txq_size=$(get_dpdk_config_value ${bond} '.n_txq_size')
|
|
local vhost_iommu_support=$(get_dpdk_config_value ${bond} '.vhost-iommu-support')
|
|
local ovs_options=$(get_dpdk_config_value ${bond} '.ovs_options')
|
|
|
|
local nic_name_str=""
|
|
local dev_args_str=""
|
|
local ip_migrated=false
|
|
|
|
echo $bond | jq -r -c '.nics[]' > /tmp/nics_array
|
|
while IFS= read -r nic; do
|
|
local pci_id=$(get_dpdk_config_value ${nic} '.pci_id')
|
|
local nic_name=$(get_dpdk_config_value ${nic} '.name')
|
|
local pmd_rxq_affinity=$(get_dpdk_config_value ${nic} '.pmd_rxq_affinity')
|
|
local vf_index=$(get_dpdk_config_value ${nic} '.vf_index')
|
|
local vf_string=""
|
|
|
|
if [[ ${migrate_ip} = "true" && ${ip_migrated} = "false" ]]; then
|
|
migrate_ip "${pci_id}" "${dpdk_bridge}"
|
|
ip_migrated=true
|
|
fi
|
|
|
|
iface=$(get_name_by_pci_id "${pci_id}")
|
|
|
|
if [ -n "${iface}" ]; then
|
|
ip link set ${iface} promisc on
|
|
if [ -n "${vf_index}" ]; then
|
|
vf_string="vf ${vf_index}"
|
|
ip link set ${iface} ${vf_string} trust on
|
|
|
|
# NOTE: To ensure proper toggle of spoofchk,
|
|
# turn it on then off.
|
|
ip link set ${iface} ${vf_string} spoofchk on
|
|
ip link set ${iface} ${vf_string} spoofchk off
|
|
fi
|
|
fi
|
|
|
|
# Fetch the PCI to be bound to DPDK driver.
|
|
# In case VF Index is configured then PCI of that particular VF
|
|
# is bound to DPDK, otherwise PF PCI is bound to DPDK.
|
|
get_pf_or_vf_pci "${pci_id}" "${vf_index}"
|
|
|
|
bind_dpdk_nic ${target_driver} "${dpdk_pci_id}"
|
|
|
|
nic_name_str+=" "${nic_name}""
|
|
dev_args_str+=" -- set Interface "${nic_name}" type=dpdk options:dpdk-devargs=""${dpdk_pci_id}"
|
|
|
|
if [[ -n ${mtu} ]]; then
|
|
dev_args_str+=" -- set Interface "${nic_name}" mtu_request=${mtu}"
|
|
fi
|
|
|
|
if [[ -n ${n_rxq} ]]; then
|
|
dev_args_str+=" -- set Interface "${nic_name}" options:n_rxq=${n_rxq}"
|
|
fi
|
|
|
|
if [[ -n ${n_txq} ]]; then
|
|
dev_args_str+=" -- set Interface "${nic_name}" options:n_txq=${n_txq}"
|
|
fi
|
|
|
|
if [[ -n ${ofport_request} ]]; then
|
|
dev_args_str+=" -- set Interface "${nic_name}" ofport_request=${ofport_request}"
|
|
fi
|
|
|
|
if [[ -n ${pmd_rxq_affinity} ]]; then
|
|
dev_args_str+=" -- set Interface "${nic_name}" other_config:pmd-rxq-affinity=${pmd_rxq_affinity}"
|
|
fi
|
|
|
|
if [[ -n ${n_rxq_size} ]]; then
|
|
dev_args_str+=" -- set Interface "${nic_name}" options:n_rxq_desc=${n_rxq_size}"
|
|
fi
|
|
|
|
if [[ -n ${n_txq_size} ]]; then
|
|
dev_args_str+=" -- set Interface "${nic_name}" options:n_txq_desc=${n_txq_size}"
|
|
fi
|
|
|
|
if [[ -n ${vhost_iommu_support} ]]; then
|
|
dev_args_str+=" -- set Interface "${nic_name}" options:vhost-iommu-support=${vhost_iommu_support}"
|
|
fi
|
|
done < /tmp/nics_array
|
|
|
|
if [ "${UPDATE_DPDK_BOND_CONFIG}" == "true" ]; then
|
|
echo -e "NOTE: UPDATE_DPDK_BOND_CONFIG is set to true.\
|
|
\nThis might cause disruptions in ovs traffic.\
|
|
\nTo avoid this disruption set UPDATE_DPDK_BOND_CONFIG to false."
|
|
ovs-vsctl --db=unix:${OVS_SOCKET} set Bridge "${dpdk_bridge}" other_config:update_config=true
|
|
ovs_update_config=true
|
|
else
|
|
ovs_update_config=$(ovs-vsctl --columns=other_config --no-heading -d json list bridge "${dpdk_bridge}" \
|
|
| jq -r '.[1][] as $list | if $list[0] == "update_config" then $list[1] else empty end')
|
|
fi
|
|
|
|
|
|
if [ "${ovs_update_config}" == "true" ] || [ "${ovs_update_config}" == "" ];
|
|
then
|
|
ovs-vsctl --db=unix:${OVS_SOCKET} --if-exists del-port "${bond_name}"
|
|
ovs-vsctl --db=unix:${OVS_SOCKET} set Bridge "${dpdk_bridge}" other_config:update_config=false
|
|
ovs-vsctl --db=unix:${OVS_SOCKET} --may-exist add-bond "${dpdk_bridge}" "${bond_name}" \
|
|
${nic_name_str} \
|
|
"${ovs_options}" ${dev_args_str}
|
|
fi
|
|
|
|
done < "/tmp/bonds_array"
|
|
}
|
|
|
|
function set_dpdk_module_log_level {
|
|
# loop over all target modules
|
|
if [ -n "$(get_dpdk_config_value ${DPDK_CONFIG} '.modules')" ]; then
|
|
echo $DPDK_CONFIG | jq -r -c '.modules[]' > /tmp/modules_array
|
|
while IFS= read -r module; do
|
|
local mod_name=$(get_dpdk_config_value ${module} '.name')
|
|
local mod_level=$(get_dpdk_config_value ${module} '.log_level')
|
|
|
|
ovs-appctl -t ${OVS_CTL} vlog/set ${mod_name}:${mod_level}
|
|
ovs-appctl -t ${OVS_CTL} vlog/list|grep ${mod_name}
|
|
done < /tmp/modules_array
|
|
fi
|
|
}
|
|
|
|
function get_driver_by_address {
|
|
if [[ -e /sys/bus/pci/devices/$1/driver ]]; then
|
|
echo $(ls /sys/bus/pci/devices/$1/driver -al | awk '{n=split($NF,a,"/"); print a[n]}')
|
|
fi
|
|
}
|
|
|
|
function init_ovs_dpdk_bridge {
|
|
bridge=$1
|
|
ovs-vsctl --db=unix:${OVS_SOCKET} --may-exist add-br ${bridge} \
|
|
-- set Bridge ${bridge} datapath_type=netdev
|
|
ip link set ${bridge} up
|
|
}
|
|
|
|
# create all additional bridges defined in the DPDK section
|
|
function init_ovs_dpdk_bridges {
|
|
for br in $(get_dpdk_config_value ${DPDK_CONFIG} '.bridges[].name'); do
|
|
init_ovs_dpdk_bridge ${br}
|
|
done
|
|
}
|
|
|
|
# handle any bridge mappings
|
|
# /tmp/auto_bridge_add is one line json file: {"br-ex1":"eth1","br-ex2":"eth2"}
|
|
for bmap in `sed 's/[{}"]//g' /tmp/auto_bridge_add | tr "," "\n"`
|
|
do
|
|
bridge=${bmap%:*}
|
|
iface=${bmap#*:}
|
|
ovs-vsctl --no-wait --may-exist add-br $bridge
|
|
if [ -n "$iface" ] && [ "$iface" != "null" ]
|
|
then
|
|
ovs-vsctl --no-wait --may-exist add-port $bridge $iface
|
|
migrate_ip_from_nic $iface $bridge
|
|
if [[ $(get_dpdk_config_value ${DPDK_CONFIG} '.enabled') != "true" ]]; then
|
|
ip link set dev $iface up
|
|
fi
|
|
fi
|
|
done
|
|
|
|
tunnel_types="{{- .Values.conf.plugins.openvswitch_agent.agent.tunnel_types -}}"
|
|
if [[ -n "${tunnel_types}" ]] ; then
|
|
tunnel_interface="{{- .Values.network.interface.tunnel -}}"
|
|
if [ -z "${tunnel_interface}" ] ; then
|
|
# search for interface with tunnel network routing
|
|
tunnel_network_cidr="{{- .Values.network.interface.tunnel_network_cidr -}}"
|
|
if [ -z "${tunnel_network_cidr}" ] ; then
|
|
tunnel_network_cidr="0/0"
|
|
fi
|
|
# If there is not tunnel network gateway, exit
|
|
tunnel_interface=$(ip -4 route list ${tunnel_network_cidr} | awk -F 'dev' '{ print $2; exit }' \
|
|
| awk '{ print $1 }') || exit 1
|
|
fi
|
|
fi
|
|
|
|
if [[ "${DPDK_ENABLED}" == "true" ]]; then
|
|
init_ovs_dpdk_bridges
|
|
process_dpdk_nics
|
|
process_dpdk_bonds
|
|
set_dpdk_module_log_level
|
|
fi
|
|
|
|
# determine local-ip dynamically based on interface provided but only if tunnel_types is not null
|
|
if [[ -n "${tunnel_types}" ]] ; then
|
|
LOCAL_IP=$(get_ip_address_from_interface ${tunnel_interface})
|
|
if [ -z "${LOCAL_IP}" ] ; then
|
|
echo "Var LOCAL_IP is empty"
|
|
exit 1
|
|
fi
|
|
|
|
tee > /tmp/pod-shared/ml2-local-ip.ini << EOF
|
|
[ovs]
|
|
local_ip = "${LOCAL_IP}"
|
|
EOF
|
|
|
|
if [[ "${DPDK_ENABLED}" == "true" ]]; then
|
|
PREFIX=$(get_ip_prefix_from_interface "${tunnel_interface}")
|
|
|
|
# loop over all nics
|
|
echo $DPDK_CONFIG | jq -r -c '.bridges[]' | \
|
|
while IFS= read -r br; do
|
|
bridge_name=$(get_dpdk_config_value ${br} '.name')
|
|
tunnel_underlay_vlan=$(get_dpdk_config_value ${br} '.tunnel_underlay_vlan')
|
|
|
|
if [[ "${bridge_name}" == "${tunnel_interface}" ]]; then
|
|
# Route the tunnel traffic via the physical bridge
|
|
if [[ -n "${LOCAL_IP}" && -n "${PREFIX}" ]]; then
|
|
if [[ -n $(ovs-appctl -t ${OVS_CTL} ovs/route/show | grep "${LOCAL_IP}" | grep -v '^Cached:') ]]; then
|
|
ovs-appctl -t ${OVS_CTL} ovs/route/del "${LOCAL_IP}"/"${PREFIX}"
|
|
fi
|
|
ovs-appctl -t ${OVS_CTL} ovs/route/add "${LOCAL_IP}"/"${PREFIX}" "${tunnel_interface}"
|
|
|
|
if [[ -n "${tunnel_underlay_vlan}" ]]; then
|
|
# If there is not tunnel network gateway, exit
|
|
IFS=. read -r i1 i2 i3 i4 <<< "${LOCAL_IP}"
|
|
IFS=. read -r xx m1 m2 m3 m4 <<< $(for a in $(seq 1 32); do if [ $(((a - 1) % 8)) -eq 0 ]; then echo -n .; fi; if [ $a -le ${PREFIX} ]; then echo -n 1; else echo -n 0; fi; done)
|
|
tunnel_network_cidr=$(printf "%d.%d.%d.%d\n" "$((i1 & (2#$m1)))" "$((i2 & (2#$m2)))" "$((i3 & (2#$m3)))" "$((i4 & (2#$m4)))") || exit 1
|
|
# Put a new flow to tag all the tunnel traffic with configured vlan-id
|
|
if [[ -n $(ovs-ofctl dump-flows "${tunnel_interface}" | grep "nw_dst=${tunnel_network_cidr}") ]]; then
|
|
ovs-ofctl del-flows "${tunnel_interface}" "cookie=0x9999/-1, table=0, ip,nw_dst=${tunnel_network_cidr}"
|
|
fi
|
|
ovs-ofctl add-flow "${tunnel_interface}" "cookie=0x9999, table=0, priority=8, ip,nw_dst=${tunnel_network_cidr}, actions=mod_vlan_vid:${tunnel_underlay_vlan},NORMAL"
|
|
fi
|
|
fi
|
|
break
|
|
fi
|
|
done
|
|
fi
|
|
fi
|
|
|
|
{{- if and ( empty .Values.conf.neutron.DEFAULT.host ) ( .Values.pod.use_fqdn.neutron_agent ) }}
|
|
mkdir -p /tmp/pod-shared
|
|
tee > /tmp/pod-shared/neutron-agent.ini << EOF
|
|
[DEFAULT]
|
|
host = $(hostname --fqdn)
|
|
EOF
|
|
{{- end }}
|