Merge "reviewed alarm-state-config, without changing state to severity in code"
This commit is contained in:
commit
fa24ee3c96
@ -1,11 +1,29 @@
|
|||||||
=========================
|
============================
|
||||||
Alarm State Configuration
|
Alarm Severity Configuration
|
||||||
=========================
|
============================
|
||||||
|
|
||||||
Configure Access to Alarm State
|
Overview
|
||||||
-------------------------------
|
--------
|
||||||
|
|
||||||
The following should be set in **/etc/vitrage/vitrage.conf**, under entity_graph section:
|
Vitrage retrieves information from diverse data-sources regarding alarms in
|
||||||
|
the cloud, and stores and combines this information into a unified system
|
||||||
|
model. An important property of an alarm is its **severity**. This severity can
|
||||||
|
be used both in the Vitrage templates to trigger actions, and in the Horizon UI
|
||||||
|
for color-coding purposes. Therefore, it is important that within the Vitrage
|
||||||
|
data model, severity names are normalized.
|
||||||
|
|
||||||
|
Since each data-source might represent severity differently, for each
|
||||||
|
data-source we can supply it's own mapping to the normalized severity supported
|
||||||
|
in Vitrage. This page explains how to handle this mapping for a given
|
||||||
|
data-source.
|
||||||
|
|
||||||
|
|
||||||
|
Configure Access to Alarm Severity
|
||||||
|
----------------------------------
|
||||||
|
|
||||||
|
The alarm severity configuration is handled via config files. The location of
|
||||||
|
these files can be determined in **/etc/vitrage/vitrage.conf**. Under the
|
||||||
|
[entity_graph] section, set:
|
||||||
|
|
||||||
+----------------------+------------------------------------+--------------------------------+
|
+----------------------+------------------------------------+--------------------------------+
|
||||||
| Name | Description | Default Value |
|
| Name | Description | Default Value |
|
||||||
@ -18,40 +36,59 @@ The following should be set in **/etc/vitrage/vitrage.conf**, under entity_graph
|
|||||||
Configure Alarm State Mapping
|
Configure Alarm State Mapping
|
||||||
-----------------------------
|
-----------------------------
|
||||||
|
|
||||||
Alarm state configuration is made to configure how states of specific alarm are normalized.
|
The alarm severity configuration files configure how the severity of each
|
||||||
For each normalized state a priority is set as well, so that when alarm will have the original state and the Vitrage state, Vitrage will know what state is more important.
|
alarm is normalized. There are several guidelines for creating a config file:
|
||||||
UNKNOWN state has to be configured in each alarm state configuration file.
|
|
||||||
|
|
||||||
The file name has to be in the same name as it's plugin name.
|
- Normalized alarm states which can be mapped to can be found in
|
||||||
State configuration yaml file has to be defined for all the plugins which were chosen to be used in Vitrage.
|
normalized_alarm_severity.py (NormalizedAlarmSeverity class).
|
||||||
|
- Each normalized severity also comes with a priority, so
|
||||||
|
that if an alarm is given different severities from different sources (e.g.,
|
||||||
|
a host alarm raised both by nagios and Vitrage), the severity with the
|
||||||
|
highest priority will be used as the **aggregated state**.
|
||||||
|
- The *UNKNOWN* severity will be used for severities with no corresponding
|
||||||
|
normalized severity. This severity *must* appear in the config file.
|
||||||
|
- The config file is in YAML format.
|
||||||
|
- The config filename must be <datasource name>.yaml, for the relevant
|
||||||
|
datasource.
|
||||||
|
- Defining a config file for each datasource is recommended, but not mandatory.
|
||||||
|
Datasources with no such configuration will use the states as-is.
|
||||||
|
|
||||||
**Format**
|
|
||||||
|
Default Configuration
|
||||||
|
+++++++++++++++++++++
|
||||||
|
|
||||||
|
Default configurations for alarms severities will be installed with Vitrage for
|
||||||
|
all the pre-packaged data-sources.
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
Format
|
||||||
|
++++++
|
||||||
::
|
::
|
||||||
|
|
||||||
category: ALARM
|
category: ALARM
|
||||||
states:
|
states:
|
||||||
- normalized state:
|
- normalized state:
|
||||||
name: <Normalized alarm state name - must be from NormalizedAlarmState class>
|
name: <normalized alarm severity>
|
||||||
priority: <Alarm state priority - an integer>
|
priority: <Alarm severity priority - an integer>
|
||||||
original states:
|
original states:
|
||||||
- name: <Original alarm state name>
|
- name: <Original alarm severity name>
|
||||||
- name: <Original alarm state name>
|
- name: ... # can list several severities for one normalized
|
||||||
- normalized state:
|
- normalized state:
|
||||||
name: <Normalized alarm state name - must be from NormalizedAlarmState class>
|
name: ... # can list several normalized severities
|
||||||
priority: <Alarm state priority - an integer>
|
...
|
||||||
original states:
|
|
||||||
- name: <Original alarm state name>
|
|
||||||
- name: <Original alarm state name>
|
|
||||||
|
|
||||||
|
|
||||||
...
|
...
|
||||||
|
|
||||||
|
|
||||||
**Example**
|
Example
|
||||||
|
+++++++
|
||||||
|
|
||||||
The following file will map alarm states.
|
The following file will map alarm severities.
|
||||||
Original states 'CRITICAL' and 'DOWN' will be mapped to normalized state 'CRITICAL'.
|
Original severities 'CRITICAL' and 'DOWN' will be mapped to normalized state
|
||||||
Normalized state 'SEVERE' has no original states.
|
'CRITICAL'. Normalized state 'SEVERE' has no original severity.
|
||||||
Original state 'WARNING' is mapped to normalized state 'WARNING', etc.
|
Original state 'WARNING' is mapped to normalized state 'WARNING', etc.
|
||||||
|
|
||||||
::
|
::
|
||||||
@ -84,12 +121,3 @@ Original state 'WARNING' is mapped to normalized state 'WARNING', etc.
|
|||||||
original states:
|
original states:
|
||||||
- name: OK
|
- name: OK
|
||||||
- name: UP
|
- name: UP
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
**Default Configuration**
|
|
||||||
|
|
||||||
Default configurations for alarms states will be installed with Vitrage.
|
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
Loading…