Hardware Requirements in StarlingX (r6,r5)

Provide inline access to referenced diagrams.

Closes-Bug: 1906630

Signed-off-by: Ron Stone <ronald.stone@windriver.com>
Change-Id: Ic09cfcb38ca060c2e60cf468fa78f183592f580e
This commit is contained in:
Ron Stone 2022-04-11 09:06:59 -04:00
parent 366277308c
commit 7a0e8c1172
7 changed files with 60 additions and 11 deletions

View File

@ -55,4 +55,15 @@ host types are:
Prepare bare metal servers
--------------------------
.. include:: prep_servers.txt
.. include:: prep_servers.txt
* Cabled for networking
* Far-end switch ports should be properly configured to realize the networking
shown in the following diagram.
.. figure:: /deploy_install_guides/r6_release/figures/starlingx-deployment-options-duplex.png
:scale: 50%
:alt: All-in-one Duplex deployment configuration
*All-in-one Duplex deployment configuration*

View File

@ -58,3 +58,14 @@ Prepare bare metal servers
--------------------------
.. include:: prep_servers.txt
* Cabled for networking
* Far-end switch ports should be properly configured to realize the networking
shown in the following diagram.
.. figure:: /deploy_install_guides/r6_release/figures/starlingx-deployment-options-simplex.png
:scale: 50%
:alt: All-in-one Simplex deployment configuration
*All-in-one Simplex deployment configuration*

View File

@ -53,4 +53,15 @@ host types are:
Prepare bare metal servers
--------------------------
.. include:: prep_servers.txt
.. include:: prep_servers.txt
* Cabled for networking
* Far-end switch ports should be properly configured to realize the networking
shown in the following diagram.
.. figure:: /deploy_install_guides/r6_release/figures/starlingx-deployment-options-controller-storage.png
:scale: 50%
:alt: Controller storage deployment configuration
*Controller storage deployment configuration*

View File

@ -58,4 +58,15 @@ host types are:
Prepare bare metal servers
--------------------------
.. include:: prep_servers.txt
.. include:: prep_servers.txt
* Cabled for networking
* Far-end switch ports should be properly configured to realize the networking
shown in the following diagram.
.. figure:: /deploy_install_guides/r6_release/figures/starlingx-deployment-options-dedicated-storage.png
:scale: 50%
:alt: Standard with dedicated storage
*Standard with dedicated storage*

View File

@ -5,13 +5,8 @@ the following condition:
* Cabled for power
* Cabled for networking
* Far-end switch ports should be properly configured to realize the networking
shown in Figure 1.
* All disks wiped
* Ensures that servers will boot from either the network or USB storage (if present)
* Powered off
* Powered off

View File

@ -60,3 +60,14 @@ Prepare bare metal servers
--------------------------
.. include:: prep_servers.txt
* Cabled for networking
* Far-end switch ports should be properly configured to realize the networking
shown in the following diagram.
.. figure:: /deploy_install_guides/r6_release/figures/starlingx-deployment-options-controller-storage.png
:scale: 50%
:alt: Standard with Rook Storage deployment configuration
*Standard with Rook Storage deployment configuration*

View File

@ -10,8 +10,7 @@ following benefits:
.. note::
If you are behind a corporate firewall or proxy, you need to set proxy
settings. Refer to :ref:`docker_proxy_config` for
details.
settings. Refer to :ref:`docker_proxy_config` for details.
.. figure:: /deploy_install_guides/r6_release/figures/starlingx-deployment-options-simplex.png
:scale: 50%