Updated topics for more clarity
Updated Patchset 1 comments Signed-off-by: Juanita-Balaraj <juanita.balaraj@windriver.com> Change-Id: I5b1e3d4e79a328a9d3aa1c496873b98c516ab95f Signed-off-by: Juanita-Balaraj <juanita.balaraj@windriver.com>
This commit is contained in:
parent
4d8775ca61
commit
c2d2312c1d
@ -37,11 +37,11 @@ follows:
|
||||
|
||||
.. rubric:: |prereq|
|
||||
|
||||
For |AIO-SX| subclouds, end user container images in `registry.local` will be
|
||||
backed up during the upgrade process. This only includes images other than
|
||||
|prod| system and application images. These images are limited to 5 GBytes in
|
||||
total size. If the system contains more than 5 GBytes of these images, the
|
||||
upgrade start will fail.
|
||||
For all deployment configurations, end user container images in
|
||||
`registry.local` will be backed up during the upgrade process. This only
|
||||
includes images other than |prod| system and application images. These images
|
||||
are limited to 5 GB in total size. If the system contains more than 5 GB of
|
||||
these images, the upgrade start will fail.
|
||||
|
||||
The following prerequisites apply to a |prod-dc| upgrade management service.
|
||||
|
||||
@ -75,15 +75,6 @@ The following prerequisites apply to a |prod-dc| upgrade management service.
|
||||
- The subclouds must all be |AIO-SX|, and must use the Redfish
|
||||
platform management service.
|
||||
|
||||
- **Remove Non GA Applications**:
|
||||
|
||||
- Use the :command:`system application-remove` and :command:`system
|
||||
application-delete` commands to remove the application on the
|
||||
subclouds:
|
||||
|
||||
- Remove any non-GA and |prefix|-openstack applications, from the
|
||||
|prod-dc| system, if they exist.
|
||||
|
||||
.. only:: partner
|
||||
|
||||
.. include:: /_includes/upgrade-management-overview.rest
|
||||
|
@ -57,7 +57,7 @@ has upgraded successfully.
|
||||
complete.
|
||||
|
||||
You can view the downgrade progress on controller-1 using the
|
||||
BMC console.
|
||||
serial console.
|
||||
|
||||
#. Unlock controller-1.
|
||||
|
||||
|
@ -2,9 +2,9 @@
|
||||
.. btn1592861794542
|
||||
.. _upgrading-all-in-one-duplex-or-standard:
|
||||
|
||||
======================================
|
||||
====================================
|
||||
Upgrade All-in-One Duplex / Standard
|
||||
======================================
|
||||
====================================
|
||||
|
||||
You can upgrade the |prod| Duplex or Standard configurations with a new release
|
||||
of |prod| software.
|
||||
@ -141,9 +141,9 @@ of |prod| software.
|
||||
No instances running on controller-1: [OK]
|
||||
|
||||
By default, the upgrade process cannot be run and is not recommended to be
|
||||
run with Active Alarms present. However, management affecting alarms can be
|
||||
ignored with the :command:`--force` option with the :command:`system
|
||||
upgrade-start` command to force the upgrade process to start.
|
||||
run with active alarms present. Use the command :command:`system upgrade-start --force`
|
||||
to force the upgrade process to start and ignore non-management-affecting
|
||||
alarms.
|
||||
|
||||
.. note::
|
||||
It is strongly recommended that you clear your system of any and all
|
||||
@ -169,9 +169,9 @@ of |prod| software.
|
||||
| to_release | nn.nn |
|
||||
+--------------+--------------------------------------+
|
||||
|
||||
This will make a copy of the system data to be used in the upgrade.
|
||||
Configuration changes are not allowed after this point until the swact to
|
||||
controller-1 is completed.
|
||||
This will make a copy of the upgrade data onto a DRBD file system to be used
|
||||
in the upgrade. Configuration changes are not allowed after this point
|
||||
until the swact to controller-1 is completed.
|
||||
|
||||
The following upgrade state applies once this command is executed:
|
||||
|
||||
@ -193,7 +193,7 @@ of |prod| software.
|
||||
|
||||
.. note::
|
||||
Use the command :command:`system upgrade-start --force` to force the
|
||||
upgrades process to start and to ignore management affecting alarms.
|
||||
upgrade process to start and ignore non-management-affecting alarms.
|
||||
This should ONLY be done if you feel these alarms will not be an issue
|
||||
over the upgrades process.
|
||||
|
||||
@ -235,7 +235,7 @@ of |prod| software.
|
||||
complete.
|
||||
|
||||
You can view the upgrade progress on controller-1 using the
|
||||
BMC console.
|
||||
serial console.
|
||||
|
||||