Updated topics for more clarity

Updated Patchset 1 comments
Signed-off-by: Juanita-Balaraj <juanita.balaraj@windriver.com>
Change-Id: I5b1e3d4e79a328a9d3aa1c496873b98c516ab95f
Signed-off-by: Juanita-Balaraj <juanita.balaraj@windriver.com>
This commit is contained in:
Juanita-Balaraj 2021-11-10 15:03:36 -05:00
parent 4d8775ca61
commit c2d2312c1d
3 changed files with 16 additions and 25 deletions

View File

@ -37,11 +37,11 @@ follows:
.. rubric:: |prereq|
For |AIO-SX| subclouds, end user container images in`registry.local` will be
backed up during the upgrade process. This only includes images other than
|prod| system and application images. These images are limited to 5 GBytes in
total size. If the system contains more than 5 GBytes of these images, the
upgrade start will fail.
For all deployment configurations, end user container images in
`registry.local` will be backed up during the upgrade process. This only
includes images other than |prod| system and application images. These images
are limited to 5 GB in total size. If the system contains more than 5 GB of
these images, the upgrade start will fail.
The following prerequisites apply to a |prod-dc| upgrade management service.
@ -75,15 +75,6 @@ The following prerequisites apply to a |prod-dc| upgrade management service.
- The subclouds must all be |AIO-SX|, and must use the Redfish
platform management service.
- **Remove Non GA Applications**:
- Use the :command:`system application-remove` and :command:`system
application-delete` commands to remove the application on the
subclouds:
- Remove any non-GA and |prefix|-openstack applications, from the
|prod-dc| system, if they exist.
.. only:: partner
.. include:: /_includes/upgrade-management-overview.rest

View File

@ -57,7 +57,7 @@ has upgraded successfully.
complete.
You can view the downgrade progress on controller-1 using the
BMC console.
serial console.
#. Unlock controller-1.

View File

@ -2,9 +2,9 @@
.. btn1592861794542
.. _upgrading-all-in-one-duplex-or-standard:
======================================
====================================
Upgrade All-in-One Duplex / Standard
======================================
====================================
You can upgrade the |prod| Duplex or Standard configurations with a new release
of |prod| software.
@ -141,9 +141,9 @@ of |prod| software.
No instances running on controller-1: [OK]
By default, the upgrade process cannot be run and is not recommended to be
run with Active Alarms present. However, management affecting alarms can be
ignored with the :command:`--force` option with the :command:`system
upgrade-start` command to force the upgrade process to start.
run with active alarms present. Use the command :command:`system upgrade-start --force`
to force the upgrade process to start and ignore non-management-affecting
alarms.
.. note::
It is strongly recommended that you clear your system of any and all
@ -169,9 +169,9 @@ of |prod| software.
| to_release | nn.nn |
+--------------+--------------------------------------+
This will make a copy of the system data to be used in the upgrade.
Configuration changes are not allowed after this point until the swact to
controller-1 is completed.
This will make a copy of the upgrade data onto a DRBD file system to be used
in the upgrade. Configuration changes are not allowed after this point
until the swact to controller-1 is completed.
The following upgrade state applies once this command is executed:
@ -193,7 +193,7 @@ of |prod| software.
.. note::
Use the command :command:`system upgrade-start --force` to force the
upgrades process to start and to ignore management affecting alarms.
upgrade process to start and ignore non-management-affecting alarms.
This should ONLY be done if you feel these alarms will not be an issue
over the upgrades process.
@ -235,7 +235,7 @@ of |prod| software.
complete.
You can view the upgrade progress on controller-1 using the
BMC console.
serial console.
- data-migration-complete or upgrading-controllers: