Merge "Document how to set VF MTU (r5, r6, dsR6)"
This commit is contained in:
commit
d47bb5a57a
@ -27,11 +27,18 @@ pci-passthrough interface.
|
||||
A description of the data network.
|
||||
|
||||
**<mtu>**
|
||||
The MTU of the data network.
|
||||
The |MTU| of the data network.
|
||||
|
||||
.. note::
|
||||
|
||||
To attach to the data network, data interfaces must be configured
|
||||
with an equal or larger MTU.
|
||||
with an equal or larger |MTU|.
|
||||
|
||||
This is not used by the Kubernetes |SRIOV| plugin. In order to
|
||||
address the |MTU| in Kubernetes, the network attached definiition
|
||||
needs to use the tuning plugin. For more details, see the examples
|
||||
in :ref:`Create Network Attachment Definitions
|
||||
<creating-network-attachment-definitions>`.
|
||||
|
||||
**<port>**
|
||||
The port of the data network.
|
||||
|
@ -7,7 +7,7 @@ Create Network Attachment Definitions
|
||||
=====================================
|
||||
|
||||
Network attachment definition specifications must be created in order to
|
||||
reference / request an SR-IOV interface in a container specification.
|
||||
reference / request an |SRIOV| interface in a container specification.
|
||||
|
||||
.. rubric:: |context|
|
||||
|
||||
@ -20,13 +20,13 @@ container as shown in :ref:`Using Network Attachment Definitions in a Container
|
||||
|
||||
.. rubric:: |prereq|
|
||||
|
||||
You must have configured at least one SR-IOV interface on a host with the
|
||||
You must have configured at least one |SRIOV| interface on a host with the
|
||||
target datanetwork \(**datanet-a** or **datanet-b** in the example below\)
|
||||
assigned to it before creating a **NetworkAttachmentDefinition** referencing
|
||||
this data network.
|
||||
|
||||
.. note::
|
||||
The configuration for this SR-IOV interface with either a ``netdevice`` or
|
||||
The configuration for this |SRIOV| interface with either a ``netdevice`` or
|
||||
``vfio`` vf-driver determines whether the **NetworkAttachmentDefinition**
|
||||
will be a kernel network device or a DPDK network device.
|
||||
|
||||
@ -34,7 +34,7 @@ this data network.
|
||||
|
||||
.. _creating-network-attachment-definitions-steps-unordered-tbf-53z-hjb:
|
||||
|
||||
#. Create a simple SR-IOV network attachment definition file called net1.yaml
|
||||
#. Create a simple |SRIOV| network attachment definition file called net1.yaml
|
||||
associated with the data network **datanet-a**.
|
||||
|
||||
.. code-block:: yaml
|
||||
@ -58,9 +58,9 @@ this data network.
|
||||
This **NetworkAttachmentDefinition** is valid for both a kernel-based and
|
||||
a DPDK \(vfio\) based device.
|
||||
|
||||
#. Create an SR-IOV network attachment.
|
||||
#. Create an |SRIOV| network attachment.
|
||||
|
||||
- The following example creates an SR-IOV network attachment definition
|
||||
- The following example creates an |SRIOV| network attachment definition
|
||||
configured for a VLAN with an ID of 2000.
|
||||
|
||||
.. code-block:: none
|
||||
@ -80,7 +80,7 @@ this data network.
|
||||
}'
|
||||
EOF
|
||||
|
||||
- The following example creates an SR-IOV network attachment definition
|
||||
- The following example creates an |SRIOV| network attachment definition
|
||||
configured with IP Address information.
|
||||
|
||||
.. code-block:: none
|
||||
@ -117,10 +117,47 @@ this data network.
|
||||
}'
|
||||
EOF
|
||||
|
||||
|
||||
- The following example creates an |SRIOV| network attachment definition
|
||||
configured with a static IP address and |MTU| of 1950.
|
||||
|
||||
.. code-block:: none
|
||||
|
||||
~(keystone_admin)]$ cat <<EOF > net4.yaml
|
||||
apiVersion: k8s.cni.cncf.io/v1
|
||||
kind: NetworkAttachmentDefinition
|
||||
metadata:
|
||||
name: net4
|
||||
annotations:
|
||||
k8s.v1.cni.cncf.io/resourceName: intel.com/pci_sriov_net_datanet_b
|
||||
spec:
|
||||
config: '{
|
||||
"cniVersion": "0.3.0",
|
||||
"plugins":
|
||||
[
|
||||
{
|
||||
"type": "sriov",
|
||||
"ipam": {
|
||||
"type": "static",
|
||||
"addresses": [
|
||||
{
|
||||
"address": "192.168.1.2/16"
|
||||
}
|
||||
]
|
||||
}
|
||||
},
|
||||
{
|
||||
"type": "tuning",
|
||||
"mtu": 1950
|
||||
}
|
||||
]
|
||||
}'
|
||||
EOF
|
||||
|
||||
.. rubric:: |result|
|
||||
|
||||
After SR-IOV interfaces have been provisioned and the hosts labeled and
|
||||
unlocked, available SR-IOV VF resources are automatically advertised.
|
||||
After |SRIOV| interfaces have been provisioned and the hosts labeled and
|
||||
unlocked, available |SRIOV| VF resources are automatically advertised.
|
||||
|
||||
They can be referenced in subsequent |prod| operations using the appropriate
|
||||
**NetworkAttachmentDefinition** name and the following extended resource name:
|
||||
@ -145,8 +182,8 @@ would be:
|
||||
- The extended resource name will convert all dashes \('-'\) in the data
|
||||
network name into underscores \('\_'\).
|
||||
|
||||
- SR-IOV enabled interfaces using the netdevice VF driver must be
|
||||
administratively and operationally up to be advertised by the SR-IOV
|
||||
- |SRIOV| enabled interfaces using the netdevice VF driver must be
|
||||
administratively and operationally up to be advertised by the |SRIOV|
|
||||
device plugin.
|
||||
|
||||
- If multiple data networks are assigned to an interface, the VFs
|
||||
|
Loading…
x
Reference in New Issue
Block a user