Add NVMe info to R2 and R3 install guides
- Add NVMe config info (same as R1) as common info for R2 and R3 - Clarify example command to add OSD for ceph (to clarify command is example, drive may be different for user depending on setup) Closes-Bug: 1853639 Change-Id: I9250842c9a0739016054746dce45b1f17d46172f Signed-off-by: Kristal Dale <kristal.dale@intel.com>
This commit is contained in:
parent
33e5ad0462
commit
ebc686a137
@ -47,6 +47,7 @@ Archived releases
|
||||
:hidden:
|
||||
|
||||
bootable_usb
|
||||
nvme_config
|
||||
|
||||
|
||||
.. Making a new release
|
||||
|
26
doc/source/deploy_install_guides/nvme_config.rst
Normal file
26
doc/source/deploy_install_guides/nvme_config.rst
Normal file
@ -0,0 +1,26 @@
|
||||
====================================
|
||||
Configure NVMe Drive as Primary Disk
|
||||
====================================
|
||||
|
||||
To use a :abbr:`Non-Volatile Memory Express (NVMe)` drive as the primary disk for
|
||||
any of your nodes, you must configure your host and adjust kernel parameters
|
||||
during installation:
|
||||
|
||||
#. Configure the host to be in UEFI mode.
|
||||
|
||||
#. Edit the kernel boot parameter.
|
||||
|
||||
After you are presented with the StarlingX ISO boot options and have selected
|
||||
the preferred installation option (for example Standard Configuration or
|
||||
All-in-One Controller Configuration), press the TAB key to edit the kernel
|
||||
boot parameters.
|
||||
|
||||
Modify the **boot_device** and **rootfs_device** from the default **sda** so
|
||||
that it is the correct device name for the NVMe drive (for example "nvme0n1").
|
||||
|
||||
::
|
||||
|
||||
vmlinuz rootwait console=tty0 inst.text inst.stage2=hd:LABEL=oe_iso_boot
|
||||
inst.ks=hd:LABEL=oe_iso_boot:/smallsystem_ks.cfg boot_device=nvme0n1
|
||||
rootfs_device=nvme0n1 biosdevname=0 usbcore.autosuspend=-1 inst.gpt
|
||||
security_profile=standard user_namespace.enable=1 initrd=initrd.img
|
@ -31,7 +31,7 @@ host types are:
|
||||
+-------------------------+-----------------------------------------------------------+
|
||||
| Minimum memory | 64 GB |
|
||||
+-------------------------+-----------------------------------------------------------+
|
||||
| Primary disk | 500 GB SDD or NVMe |
|
||||
| Primary disk | 500 GB SDD or NVMe (see :doc:`../../nvme_config`) |
|
||||
+-------------------------+-----------------------------------------------------------+
|
||||
| Additional disks | - 1 or more 500 GB (min. 10K RPM) for Ceph OSD |
|
||||
| | - Recommended, but not required: 1 or more SSDs or NVMe |
|
||||
|
@ -220,7 +220,8 @@ Configure controller-0
|
||||
system interface-datanetwork-assign ${COMPUTE} ${DATA0IFUUID} ${PHYSNET0}
|
||||
system interface-datanetwork-assign ${COMPUTE} ${DATA1IFUUID} ${PHYSNET1}
|
||||
|
||||
#. Add an OSD on controller-0 for ceph:
|
||||
#. Add an OSD on controller-0 for ceph. The following example adds an OSD
|
||||
to the `sdb` disk:
|
||||
|
||||
::
|
||||
|
||||
|
@ -31,7 +31,7 @@ host types are:
|
||||
+-------------------------+-----------------------------------------------------------+
|
||||
| Minimum memory | 64 GB |
|
||||
+-------------------------+-----------------------------------------------------------+
|
||||
| Primary disk | 500 GB SDD or NVMe |
|
||||
| Primary disk | 500 GB SDD or NVMe (see :doc:`../../nvme_config`) |
|
||||
+-------------------------+-----------------------------------------------------------+
|
||||
| Additional disks | - 1 or more 500 GB (min. 10K RPM) for Ceph OSD |
|
||||
| | - Recommended, but not required: 1 or more SSDs or NVMe |
|
||||
|
@ -227,7 +227,8 @@ Configure controller-0
|
||||
system interface-datanetwork-assign ${COMPUTE} ${DATA0IFUUID} ${PHYSNET0}
|
||||
system interface-datanetwork-assign ${COMPUTE} ${DATA1IFUUID} ${PHYSNET1}
|
||||
|
||||
#. Add an OSD on controller-0 for ceph:
|
||||
#. Add an OSD on controller-0 for ceph. The following example adds an OSD
|
||||
to the `sdb` disk:
|
||||
|
||||
::
|
||||
|
||||
|
@ -27,7 +27,8 @@ host types are:
|
||||
+-------------------------+-----------------------------+-----------------------------+
|
||||
| Minimum memory | 64 GB | 32 GB |
|
||||
+-------------------------+-----------------------------+-----------------------------+
|
||||
| Primary disk | 500 GB SDD or NVMe | 120 GB (Minimum 10k RPM) |
|
||||
| Primary disk | 500 GB SDD or NVMe (see | 120 GB (Minimum 10k RPM) |
|
||||
| | :doc:`../../nvme_config`) | |
|
||||
+-------------------------+-----------------------------+-----------------------------+
|
||||
| Additional disks | - 1 or more 500 GB (min. | - For OpenStack, recommend |
|
||||
| | 10K RPM) for Ceph OSD | 1 or more 500 GB (min. |
|
||||
|
@ -549,7 +549,7 @@ service. This can take 5-10 minutes, depending on the performance of the host ma
|
||||
Add Ceph OSDs to controllers
|
||||
----------------------------
|
||||
|
||||
#. Add OSDs to controller-0:
|
||||
#. Add OSDs to controller-0. The following example adds OSDs to the `sdb` disk:
|
||||
|
||||
::
|
||||
|
||||
@ -564,7 +564,7 @@ Add Ceph OSDs to controllers
|
||||
|
||||
system host-stor-list $HOST
|
||||
|
||||
#. Add OSDs to controller-1:
|
||||
#. Add OSDs to controller-1. The following example adds OSDs to the `sdb` disk:
|
||||
|
||||
::
|
||||
|
||||
|
@ -17,41 +17,42 @@ Minimum hardware requirements
|
||||
The recommended minimum hardware requirements for bare metal servers for various
|
||||
host types are:
|
||||
|
||||
+---------------------+-----------------------+-----------------------+-----------------------+
|
||||
| Minimum Requirement | Controller Node | Storage Node | Compute Node |
|
||||
+=====================+=======================+=======================+=======================+
|
||||
| Number of servers | 2 | 2-9 | 2-100 |
|
||||
+---------------------+-----------------------+-----------------------+-----------------------+
|
||||
| Minimum processor | Dual-CPU Intel® Xeon® E5 26xx family (SandyBridge) 8 cores/socket |
|
||||
| class | |
|
||||
+---------------------+-----------------------+-----------------------+-----------------------+
|
||||
| Minimum memory | 64 GB | 64 GB | 32 GB |
|
||||
+---------------------+-----------------------+-----------------------+-----------------------+
|
||||
| Primary disk | 500 GB SDD or NVM | 120 GB (min. 10k RPM) | 120 GB (min. 10k RPM) |
|
||||
+---------------------+-----------------------+-----------------------+-----------------------+
|
||||
| Additional disks | None | - 1 or more 500 GB | - For OpenStack, |
|
||||
| | | (min. 10K RPM) for | recommend 1 or more |
|
||||
| | | Ceph OSD | 500 GB (min. 10K |
|
||||
| | | - Recommended, but | RPM) for VM |
|
||||
| | | not required: 1 or | ephemeral storage |
|
||||
| | | more SSDs or NVMe | |
|
||||
| | | drives for Ceph | |
|
||||
| | | journals (min. 1024 | |
|
||||
| | | MiB per OSD | |
|
||||
| | | journal) | |
|
||||
+---------------------+-----------------------+-----------------------+-----------------------+
|
||||
| Minimum network | - Mgmt/Cluster: | - Mgmt/Cluster: | - Mgmt/Cluster: |
|
||||
| ports | 1x10GE | 1x10GE | 1x10GE |
|
||||
| | - OAM: 1x1GE | | - Data: 1 or more |
|
||||
| | | | x 10GE |
|
||||
+---------------------+-----------------------+-----------------------+-----------------------+
|
||||
| BIOS settings | - Hyper-Threading technology enabled |
|
||||
| | - Virtualization technology enabled |
|
||||
| | - VT for directed I/O enabled |
|
||||
| | - CPU power and performance policy set to performance |
|
||||
| | - CPU C state control disabled |
|
||||
| | - Plug & play BMC detection disabled |
|
||||
+---------------------+-----------------------+-----------------------+-----------------------+
|
||||
+---------------------+---------------------------+-----------------------+-----------------------+
|
||||
| Minimum Requirement | Controller Node | Storage Node | Compute Node |
|
||||
+=====================+===========================+=======================+=======================+
|
||||
| Number of servers | 2 | 2-9 | 2-100 |
|
||||
+---------------------+---------------------------+-----------------------+-----------------------+
|
||||
| Minimum processor | Dual-CPU Intel® Xeon® E5 26xx family (SandyBridge) 8 cores/socket |
|
||||
| class | |
|
||||
+---------------------+---------------------------+-----------------------+-----------------------+
|
||||
| Minimum memory | 64 GB | 64 GB | 32 GB |
|
||||
+---------------------+---------------------------+-----------------------+-----------------------+
|
||||
| Primary disk | 500 GB SDD or NVMe ( see | 120 GB (min. 10k RPM) | 120 GB (min. 10k RPM) |
|
||||
| | :doc:`../../nvme_config`) | | |
|
||||
+---------------------+---------------------------+-----------------------+-----------------------+
|
||||
| Additional disks | None | - 1 or more 500 GB | - For OpenStack, |
|
||||
| | | (min. 10K RPM) for | recommend 1 or more |
|
||||
| | | Ceph OSD | 500 GB (min. 10K |
|
||||
| | | - Recommended, but | RPM) for VM |
|
||||
| | | not required: 1 or | ephemeral storage |
|
||||
| | | more SSDs or NVMe | |
|
||||
| | | drives for Ceph | |
|
||||
| | | journals (min. 1024 | |
|
||||
| | | MiB per OSD | |
|
||||
| | | journal) | |
|
||||
+---------------------+---------------------------+-----------------------+-----------------------+
|
||||
| Minimum network | - Mgmt/Cluster: | - Mgmt/Cluster: | - Mgmt/Cluster: |
|
||||
| ports | 1x10GE | 1x10GE | 1x10GE |
|
||||
| | - OAM: 1x1GE | | - Data: 1 or more |
|
||||
| | | | x 10GE |
|
||||
+---------------------+---------------------------+-----------------------+-----------------------+
|
||||
| BIOS settings | - Hyper-Threading technology enabled |
|
||||
| | - Virtualization technology enabled |
|
||||
| | - VT for directed I/O enabled |
|
||||
| | - CPU power and performance policy set to performance |
|
||||
| | - CPU C state control disabled |
|
||||
| | - Plug & play BMC detection disabled |
|
||||
+---------------------+---------------------------+-----------------------+-----------------------+
|
||||
|
||||
--------------------------
|
||||
Prepare bare metal servers
|
||||
|
@ -176,7 +176,7 @@ Configure storage nodes
|
||||
system interface-network-assign $COMPUTE mgmt0 cluster-host
|
||||
done
|
||||
|
||||
#. Add OSDs to storage-0:
|
||||
#. Add OSDs to storage-0. The following example adds OSDs to the `sdb` disk:
|
||||
|
||||
::
|
||||
|
||||
@ -191,7 +191,7 @@ Configure storage nodes
|
||||
|
||||
system host-stor-list $HOST
|
||||
|
||||
#. Add OSDs to storage-1:
|
||||
#. Add OSDs to storage-1. The following example adds OSDs to the `sdb` disk:
|
||||
|
||||
::
|
||||
|
||||
|
@ -31,7 +31,7 @@ host types are:
|
||||
+-------------------------+-----------------------------------------------------------+
|
||||
| Minimum memory | 64 GB |
|
||||
+-------------------------+-----------------------------------------------------------+
|
||||
| Primary disk | 500 GB SDD or NVMe |
|
||||
| Primary disk | 500 GB SDD or NVMe (see :doc:`../../nvme_config`) |
|
||||
+-------------------------+-----------------------------------------------------------+
|
||||
| Additional disks | - 1 or more 500 GB (min. 10K RPM) for Ceph OSD |
|
||||
| | - Recommended, but not required: 1 or more SSDs or NVMe |
|
||||
|
@ -220,7 +220,8 @@ Configure controller-0
|
||||
system interface-datanetwork-assign ${COMPUTE} ${DATA0IFUUID} ${PHYSNET0}
|
||||
system interface-datanetwork-assign ${COMPUTE} ${DATA1IFUUID} ${PHYSNET1}
|
||||
|
||||
#. Add an OSD on controller-0 for ceph:
|
||||
#. Add an OSD on controller-0 for ceph. The following example adds an OSD
|
||||
to the `sdb` disk:
|
||||
|
||||
::
|
||||
|
||||
|
@ -31,7 +31,7 @@ host types are:
|
||||
+-------------------------+-----------------------------------------------------------+
|
||||
| Minimum memory | 64 GB |
|
||||
+-------------------------+-----------------------------------------------------------+
|
||||
| Primary disk | 500 GB SDD or NVMe |
|
||||
| Primary disk | 500 GB SDD or NVMe (see :doc:`../../nvme_config`) |
|
||||
+-------------------------+-----------------------------------------------------------+
|
||||
| Additional disks | - 1 or more 500 GB (min. 10K RPM) for Ceph OSD |
|
||||
| | - Recommended, but not required: 1 or more SSDs or NVMe |
|
||||
|
@ -227,7 +227,8 @@ Configure controller-0
|
||||
system interface-datanetwork-assign ${COMPUTE} ${DATA0IFUUID} ${PHYSNET0}
|
||||
system interface-datanetwork-assign ${COMPUTE} ${DATA1IFUUID} ${PHYSNET1}
|
||||
|
||||
#. Add an OSD on controller-0 for ceph:
|
||||
#. Add an OSD on controller-0 for ceph. The following example adds an OSD
|
||||
to the `sdb` disk:
|
||||
|
||||
::
|
||||
|
||||
|
@ -27,7 +27,8 @@ host types are:
|
||||
+-------------------------+-----------------------------+-----------------------------+
|
||||
| Minimum memory | 64 GB | 32 GB |
|
||||
+-------------------------+-----------------------------+-----------------------------+
|
||||
| Primary disk | 500 GB SDD or NVMe | 120 GB (Minimum 10k RPM) |
|
||||
| Primary disk | 500 GB SDD or NVMe (see | 120 GB (Minimum 10k RPM) |
|
||||
| | :doc:`../../nvme_config`) | |
|
||||
+-------------------------+-----------------------------+-----------------------------+
|
||||
| Additional disks | - 1 or more 500 GB (min. | - For OpenStack, recommend |
|
||||
| | 10K RPM) for Ceph OSD | 1 or more 500 GB (min. |
|
||||
|
@ -549,7 +549,7 @@ service. This can take 5-10 minutes, depending on the performance of the host ma
|
||||
Add Ceph OSDs to controllers
|
||||
----------------------------
|
||||
|
||||
#. Add OSDs to controller-0:
|
||||
#. Add OSDs to controller-0. The following example adds OSDs to the `sdb` disk:
|
||||
|
||||
::
|
||||
|
||||
@ -564,7 +564,7 @@ Add Ceph OSDs to controllers
|
||||
|
||||
system host-stor-list $HOST
|
||||
|
||||
#. Add OSDs to controller-1:
|
||||
#. Add OSDs to controller-1. The following example adds OSDs to the `sdb` disk:
|
||||
|
||||
::
|
||||
|
||||
|
@ -17,41 +17,42 @@ Minimum hardware requirements
|
||||
The recommended minimum hardware requirements for bare metal servers for various
|
||||
host types are:
|
||||
|
||||
+---------------------+-----------------------+-----------------------+-----------------------+
|
||||
| Minimum Requirement | Controller Node | Storage Node | Compute Node |
|
||||
+=====================+=======================+=======================+=======================+
|
||||
| Number of servers | 2 | 2-9 | 2-100 |
|
||||
+---------------------+-----------------------+-----------------------+-----------------------+
|
||||
| Minimum processor | Dual-CPU Intel® Xeon® E5 26xx family (SandyBridge) 8 cores/socket |
|
||||
| class | |
|
||||
+---------------------+-----------------------+-----------------------+-----------------------+
|
||||
| Minimum memory | 64 GB | 64 GB | 32 GB |
|
||||
+---------------------+-----------------------+-----------------------+-----------------------+
|
||||
| Primary disk | 500 GB SDD or NVM | 120 GB (min. 10k RPM) | 120 GB (min. 10k RPM) |
|
||||
+---------------------+-----------------------+-----------------------+-----------------------+
|
||||
| Additional disks | None | - 1 or more 500 GB | - For OpenStack, |
|
||||
| | | (min. 10K RPM) for | recommend 1 or more |
|
||||
| | | Ceph OSD | 500 GB (min. 10K |
|
||||
| | | - Recommended, but | RPM) for VM |
|
||||
| | | not required: 1 or | ephemeral storage |
|
||||
| | | more SSDs or NVMe | |
|
||||
| | | drives for Ceph | |
|
||||
| | | journals (min. 1024 | |
|
||||
| | | MiB per OSD | |
|
||||
| | | journal) | |
|
||||
+---------------------+-----------------------+-----------------------+-----------------------+
|
||||
| Minimum network | - Mgmt/Cluster: | - Mgmt/Cluster: | - Mgmt/Cluster: |
|
||||
| ports | 1x10GE | 1x10GE | 1x10GE |
|
||||
| | - OAM: 1x1GE | | - Data: 1 or more |
|
||||
| | | | x 10GE |
|
||||
+---------------------+-----------------------+-----------------------+-----------------------+
|
||||
| BIOS settings | - Hyper-Threading technology enabled |
|
||||
| | - Virtualization technology enabled |
|
||||
| | - VT for directed I/O enabled |
|
||||
| | - CPU power and performance policy set to performance |
|
||||
| | - CPU C state control disabled |
|
||||
| | - Plug & play BMC detection disabled |
|
||||
+---------------------+-----------------------+-----------------------+-----------------------+
|
||||
+---------------------+---------------------------+-----------------------+-----------------------+
|
||||
| Minimum Requirement | Controller Node | Storage Node | Compute Node |
|
||||
+=====================+===========================+=======================+=======================+
|
||||
| Number of servers | 2 | 2-9 | 2-100 |
|
||||
+---------------------+---------------------------+-----------------------+-----------------------+
|
||||
| Minimum processor | Dual-CPU Intel® Xeon® E5 26xx family (SandyBridge) 8 cores/socket |
|
||||
| class | |
|
||||
+---------------------+---------------------------+-----------------------+-----------------------+
|
||||
| Minimum memory | 64 GB | 64 GB | 32 GB |
|
||||
+---------------------+---------------------------+-----------------------+-----------------------+
|
||||
| Primary disk | 500 GB SDD or NVMe (see | 120 GB (min. 10k RPM) | 120 GB (min. 10k RPM) |
|
||||
| | :doc:`../../nvme_config`) | | |
|
||||
+---------------------+---------------------------+-----------------------+-----------------------+
|
||||
| Additional disks | None | - 1 or more 500 GB | - For OpenStack, |
|
||||
| | | (min. 10K RPM) for | recommend 1 or more |
|
||||
| | | Ceph OSD | 500 GB (min. 10K |
|
||||
| | | - Recommended, but | RPM) for VM |
|
||||
| | | not required: 1 or | ephemeral storage |
|
||||
| | | more SSDs or NVMe | |
|
||||
| | | drives for Ceph | |
|
||||
| | | journals (min. 1024 | |
|
||||
| | | MiB per OSD | |
|
||||
| | | journal) | |
|
||||
+---------------------+---------------------------+-----------------------+-----------------------+
|
||||
| Minimum network | - Mgmt/Cluster: | - Mgmt/Cluster: | - Mgmt/Cluster: |
|
||||
| ports | 1x10GE | 1x10GE | 1x10GE |
|
||||
| | - OAM: 1x1GE | | - Data: 1 or more |
|
||||
| | | | x 10GE |
|
||||
+---------------------+---------------------------+-----------------------+-----------------------+
|
||||
| BIOS settings | - Hyper-Threading technology enabled |
|
||||
| | - Virtualization technology enabled |
|
||||
| | - VT for directed I/O enabled |
|
||||
| | - CPU power and performance policy set to performance |
|
||||
| | - CPU C state control disabled |
|
||||
| | - Plug & play BMC detection disabled |
|
||||
+---------------------+---------------------------+-----------------------+-----------------------+
|
||||
|
||||
--------------------------
|
||||
Prepare bare metal servers
|
||||
|
@ -176,7 +176,7 @@ Configure storage nodes
|
||||
system interface-network-assign $COMPUTE mgmt0 cluster-host
|
||||
done
|
||||
|
||||
#. Add OSDs to storage-0:
|
||||
#. Add OSDs to storage-0. The following example adds OSDs to the `sdb` disk:
|
||||
|
||||
::
|
||||
|
||||
@ -191,7 +191,7 @@ Configure storage nodes
|
||||
|
||||
system host-stor-list $HOST
|
||||
|
||||
#. Add OSDs to storage-1:
|
||||
#. Add OSDs to storage-1. The following example adds OSDs to the `sdb` disk:
|
||||
|
||||
::
|
||||
|
||||
|
Loading…
x
Reference in New Issue