.. bdx1614099833159 .. _override-default-application-values: =================================== Override Default Application Values =================================== You can override default application values using the commands described in this section. .. rubric:: |proc| #. View existing values. .. code-block:: none ~(keystone_admin)]$ system helm-override-show ptp-notification ptp-notification notification #. Create a yaml file and update the fields that require Helm overrides. .. code-block:: none cat ~/override.yaml ptptracking: device: holdover_seconds: 25 poll_freq_seconds: 2 #. Apply the values. Application values can be added by the user and applied, using the following commands. .. note:: The application could be in the "uploaded" or "applied" state. .. code-block:: none ~(keystone_admin)]$ system helm-override-update ptp-notification ptp-notification notification -–values .. code-block:: none ~(keystone_admin)]$ system application-apply ptp-notification where the values are: **simulated** value must be 'false' for a normal operation \(used only for troubleshooting\). **holdover_seconds** value is the holdover time provided by the |NIC| specification. The default is 15 seconds. **poll_freq_seconds** is the frequency that the tracking function monitors the ``ptp4l`` to derive the |PTP| sync state. The default is 2 seconds.