Trying to get the BMC password through barbican before the ping succeeds leads to an early bmc access lost failure that 1. produces a misleading bmc access lost failure log ; bmc access had not even been established yet. 2. imposes as retry wait that delays re-establishing bmc access and therefore overall sensor monitoring. This update also 1. adds hostname to some of the secretUtil API interfaces so that logs ar reported against the correct host rather than always the current controller hostname. 2. Changes some success path logging to dlogs to reduce log noise. 3. simplifies a ping ok log Change-Id: Ib3b7de212294d6dc350ee17d363f4009b3b0dcb0 Story: 2005861 Task: 36595 Signed-off-by: Eric MacDonald <eric.macdonald@windriver.com>