Eric MacDonald aefc81ec91 Fix hardware monitor degrade event handling
Long hostname support introduced a bug that causes the mtcAgent
to reject hardware monitor degrade requests due to the originating
service (daemon) not recognized.

This update fixes the parsed parameters in mtcAgent and adds
a sensor parm to the degrade API so that the sensor name
accompanying the degrade event can be logged in mtcAgent.

Test Plan: for hwmond degrade handling

PASS: verify degrade assert and sensor name in mtcAgent degrade assert log
PASS: Verify degrade clear handling and log

Change-Id: I5c11cc5f679f21e6aadd4d5be25e6c08a241e80b
Closes-Bug: 1838020
Signed-off-by: Eric MacDonald <eric.macdonald@windriver.com>
2019-07-26 09:02:08 -04:00