In order to better support the default configuration when ptp-notification is deployed on a BC, the ptp4lClockClassLockedList values should in include 135 as a locked clockClass. This change ensures that classes 6, 7 and 135 are considered acceptable for the ptp-notification locked state by default, with the ability to override the acceptable clockClasses available to the user. Test plan: PASS: Build ptp-notification helm charts PASS: Deploy ptp-notification PASS: v1 api - test ptp4lClockClassLockedList with the default list PASS: v2 api - test ptp4lClockClassLockedList with the default list Partial-bug: 2033539 Signed-off-by: Cole Walker <cole.walker@windriver.com> Change-Id: Ic569c373dc2ddf1771e83b12832ef1460266c93a |
||
---|---|---|
.. | ||