389 lines
15 KiB
Plaintext
389 lines
15 KiB
Plaintext
-- ==================================================================
|
|
-- Copyright (C) 2002 by HUAWEI TECHNOLOGIES. All rights reserved.
|
|
--
|
|
-- Description: HUAWEI private rmon alarm Information MIB.
|
|
-- Reference:
|
|
-- Version: V1.0
|
|
-- History:
|
|
-- Created by Qizhenglin, 2002.8.15
|
|
-- ==================================================================
|
|
|
|
HUAWEI-PERFORMANCE-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
DisplayString
|
|
FROM RFC1213-MIB
|
|
OBJECT-TYPE
|
|
FROM RFC-1212
|
|
OwnerString
|
|
FROM IF-MIB
|
|
hwInternetProtocol
|
|
FROM HUAWEI-MIB
|
|
EntryStatus
|
|
FROM RMON-MIB
|
|
MODULE-IDENTITY,OBJECT-IDENTITY,NOTIFICATION-TYPE,Integer32
|
|
FROM SNMPv2-SMI;
|
|
|
|
rmonExtend OBJECT IDENTIFIER ::= { hwInternetProtocol 4 }
|
|
|
|
performance MODULE-IDENTITY
|
|
LAST-UPDATED "200912222100Z"
|
|
ORGANIZATION
|
|
"Huawei Technologies co., Ltd."
|
|
CONTACT-INFO
|
|
" R&D BeiJing, Huawei Technologies co.,Ltd.
|
|
Huawei Bld.,NO.3 Xinxi Rd.,
|
|
Shang-Di Information Industry Base,
|
|
Hai-Dian District Beijing P.R. China
|
|
Zip:100085
|
|
Http://www.huawei.com
|
|
E-mail:support@huawei.com "
|
|
DESCRIPTION
|
|
"This mib is supplementary for RMON-MIB(rfc2819).
|
|
It includes only one table. The mib defines two
|
|
new objects. One is to set the alarm object by
|
|
expression, the other is to limit the existing
|
|
time of an alarm row. notices."
|
|
REVISION "200706122100Z"
|
|
DESCRIPTION
|
|
"The initial revision of this MIB module ."
|
|
::= { rmonExtend 4 }
|
|
|
|
prialarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PriAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of alarm entries."
|
|
::= { performance 1 }
|
|
|
|
prialarmEntry OBJECT-TYPE
|
|
SYNTAX PriAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of parameters that set up a periodic checking
|
|
for alarm conditions. For example, an instance of the
|
|
alarmValue object might be named alarmValue.8"
|
|
INDEX { prialarmIndex }
|
|
::= { prialarmTable 1 }
|
|
|
|
PriAlarmEntry ::= SEQUENCE {
|
|
prialarmIndex Integer32 (1..65535),
|
|
prialarmInterval Integer32,
|
|
prialarmVariable DisplayString,
|
|
prialarmSympol DisplayString,
|
|
prialarmSampleType INTEGER,
|
|
prialarmValue Integer32,
|
|
prialarmStartupAlarm INTEGER,
|
|
prialarmRisingThreshold Integer32,
|
|
prialarmFallingThreshold Integer32,
|
|
prialarmRisingEventIndex Integer32 (0..65535),
|
|
prialarmFallingEventIndex Integer32 (0..65535),
|
|
prialarmStatCycle Integer32,
|
|
prialarmStatType INTEGER,
|
|
prialarmOwner OwnerString,
|
|
prialarmStatus EntryStatus
|
|
}
|
|
|
|
prialarmIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..65535)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index that uniquely identifies an entry in the
|
|
alarm table. Each such entry defines a
|
|
diagnostic sample at a particular interval
|
|
for an object on the device."
|
|
::= { prialarmEntry 1 }
|
|
|
|
prialarmInterval OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The interval in seconds over which the data is
|
|
sampled and compared with the rising and falling
|
|
thresholds. When setting this variable, care
|
|
should be taken in the case of deltaValue
|
|
sampling - the interval should be set short enough
|
|
that the sampled variable is very unlikely to
|
|
increase or decrease by more than 2^31 - 1 during
|
|
a single sampling interval.
|
|
|
|
This object may not be modified if the associated
|
|
alarmStatus object is equal to valid(1)."
|
|
::= { prialarmEntry 2 }
|
|
|
|
prialarmVariable OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object identifier of the particular variable to be
|
|
sampled. Only variables that resolve to an ASN.1 primitive
|
|
type of INTEGER (INTEGER, Integer32, Counter32, Counter64,
|
|
Gauge, or TimeTicks) may be sampled.
|
|
|
|
Because SNMP access control is articulated entirely
|
|
in terms of the contents of MIB views, no access
|
|
control mechanism exists that can restrict the value of
|
|
this object to identify only those objects that exist
|
|
in a particular MIB view. Because there is thus no
|
|
acceptable means of restricting the read access that
|
|
could be obtained through the alarm mechanism, the
|
|
probe must only grant write access to this object in
|
|
those views that have read access to all objects on
|
|
the probe.
|
|
|
|
During a set operation, if the supplied variable name is
|
|
not available in the selected MIB view, a badValue error
|
|
must be returned. If at any time the variable name of
|
|
an established alarmEntry is no longer available in the
|
|
selected MIB view, the probe must change the status of
|
|
this alarmEntry to invalid(4).
|
|
|
|
This object may not be modified if the associated
|
|
alarmStatus object is equal to valid(1)."
|
|
::= { prialarmEntry 3 }
|
|
|
|
prialarmSympol OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The string which the alarm line described."
|
|
::= {prialarmEntry 4 }
|
|
|
|
prialarmSampleType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
absoluteValue(1),
|
|
deltaValue(2),
|
|
changeratioValue(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The method of sampling the selected variable and
|
|
calculating the value to be compared against the
|
|
thresholds. If the value of this object is
|
|
absoluteValue(1), the value of the selected variable
|
|
will be compared directly with the thresholds at the
|
|
end of the sampling interval. If the value of this
|
|
object is deltaValue(2), the value of the selected
|
|
variable at the last sample will be subtracted from
|
|
the current value, and the difference compared with
|
|
the thresholds.If the value of this object is
|
|
changeratioValue(3),the value of the selected variable
|
|
will be the change ratio of the selected variable,
|
|
which is that the value of the selected variable at
|
|
the last sample will be substracted from the current
|
|
value,and the difference divided by the sampling
|
|
interval,and the result compared with the thresholds.
|
|
|
|
This object may not be modified if the associated
|
|
alarmStatus object is equal to valid(1)."
|
|
::= { prialarmEntry 5 }
|
|
|
|
prialarmValue OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of the statistic during the last sampling
|
|
period. For example, if the sample type is deltaValue,
|
|
this value will be the difference between the samples
|
|
at the beginning and end of the period. If the sample
|
|
type is absoluteValue, this value will be the sampled
|
|
value at the end of the period.
|
|
This is the value that is compared with the rising and
|
|
falling thresholds.
|
|
|
|
The value during the current sampling period is not
|
|
made available until the period is completed and will
|
|
remain available until the next period completes."
|
|
::= { prialarmEntry 6 }
|
|
|
|
prialarmStartupAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
risingAlarm(1),
|
|
fallingAlarm(2),
|
|
risingOrFallingAlarm(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The alarm that may be sent when this entry is first
|
|
set to valid. If the first sample after this entry
|
|
becomes valid is greater than or equal to the
|
|
risingThreshold and alarmStartupAlarm is equal to
|
|
risingAlarm(1) or risingOrFallingAlarm(3), then a single
|
|
rising alarm will be generated. If the first sample
|
|
after this entry becomes valid is less than or equal
|
|
to the fallingThreshold and alarmStartupAlarm is equal
|
|
to fallingAlarm(2) or risingOrFallingAlarm(3), then a
|
|
single falling alarm will be generated.
|
|
|
|
This object may not be modified if the associated
|
|
alarmStatus object is equal to valid(1)."
|
|
::= { prialarmEntry 7 }
|
|
|
|
prialarmRisingThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A threshold for the sampled statistic. When the current
|
|
sampled value is greater than or equal to this threshold,
|
|
and the value at the last sampling interval was less than
|
|
this threshold, a single event will be generated.
|
|
A single event will also be generated if the first
|
|
sample after this entry becomes valid is greater than or
|
|
equal to this threshold and the associated
|
|
alarmStartupAlarm is equal to risingAlarm(1) or
|
|
risingOrFallingAlarm(3).
|
|
|
|
After a rising event is generated, another such event
|
|
will not be generated until the sampled value
|
|
falls below this threshold and reaches the
|
|
alarmFallingThreshold.
|
|
|
|
This object may not be modified if the associated
|
|
alarmStatus object is equal to valid(1)."
|
|
::= { prialarmEntry 8 }
|
|
|
|
prialarmFallingThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A threshold for the sampled statistic. When the current
|
|
sampled value is less than or equal to this threshold,
|
|
and the value at the last sampling interval was greater than
|
|
this threshold, a single event will be generated.
|
|
A single event will also be generated if the first
|
|
sample after this entry becomes valid is less than or
|
|
equal to this threshold and the associated
|
|
alarmStartupAlarm is equal to fallingAlarm(2) or
|
|
risingOrFallingAlarm(3).
|
|
|
|
After a falling event is generated, another such event
|
|
will not be generated until the sampled value
|
|
rises above this threshold and reaches the
|
|
alarmRisingThreshold.
|
|
|
|
This object may not be modified if the associated
|
|
alarmStatus object is equal to valid(1)."
|
|
::= { prialarmEntry 9 }
|
|
|
|
prialarmRisingEventIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the eventEntry that is
|
|
used when a rising threshold is crossed. The
|
|
eventEntry identified by a particular value of
|
|
this index is the same as identified by the same value
|
|
of the eventIndex object. If there is no
|
|
corresponding entry in the eventTable, then
|
|
no association exists. In particular, if this value
|
|
is zero, no associated event will be generated, as
|
|
zero is not a valid event index.
|
|
|
|
This object may not be modified if the associated
|
|
alarmStatus object is equal to valid(1)."
|
|
::= { prialarmEntry 10 }
|
|
|
|
prialarmFallingEventIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..65535)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the eventEntry that is
|
|
used when a falling threshold is crossed. The
|
|
eventEntry identified by a particular value of
|
|
this index is the same as identified by the same value
|
|
of the eventIndex object. If there is no
|
|
corresponding entry in the eventTable, then
|
|
no association exists. In particular, if this value
|
|
is zero, no associated event will be generated, as
|
|
zero is not a valid event index.
|
|
|
|
This object may not be modified if the associated
|
|
alarmStatus object is equal to valid(1)."
|
|
::= { prialarmEntry 11 }
|
|
|
|
prialarmStatCycle OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The time alarm line exists. When the value
|
|
of prialarmStatType is during(2),set prialarmStatCycle
|
|
to decide how long the alarm line exists."
|
|
::= { prialarmEntry 12 }
|
|
|
|
|
|
prialarmStatType OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
forever(1),
|
|
during(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"It expresses alarm state type.To choose forever(1)
|
|
, the alarm line will exist forever. To choose
|
|
during(2) , the alarm line will be deleted after
|
|
the time setting for 'prialarmStatCycle'."
|
|
::= { prialarmEntry 13 }
|
|
|
|
prialarmOwner OBJECT-TYPE
|
|
SYNTAX OwnerString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The entity that configured this entry and is therefore
|
|
using the resources assigned to it."
|
|
::= { prialarmEntry 14 }
|
|
|
|
prialarmStatus OBJECT-TYPE
|
|
SYNTAX EntryStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of this alarm entry."
|
|
::= { prialarmEntry 15 }
|
|
|
|
-- extend from Remote Network Monitoring Traps
|
|
|
|
rmonExtendEventsV2 OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION "Definition point for pri RMON notifications."
|
|
::= { rmonExtend 0 }
|
|
|
|
pririsingAlarm NOTIFICATION-TYPE
|
|
OBJECTS { prialarmIndex, prialarmSympol, prialarmSampleType,
|
|
prialarmValue, prialarmRisingThreshold }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SNMP trap that is generated when an alarm
|
|
entry crosses its rising threshold and generates
|
|
an event that is configured for sending SNMP
|
|
traps."
|
|
::= { rmonExtendEventsV2 1 }
|
|
|
|
prifallingAlarm NOTIFICATION-TYPE
|
|
OBJECTS { prialarmIndex, prialarmSympol, prialarmSampleType,
|
|
prialarmValue, prialarmFallingThreshold }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SNMP trap that is generated when an alarm
|
|
entry crosses its falling threshold and generates
|
|
an event that is configured for sending SNMP
|
|
traps."
|
|
::= { rmonExtendEventsV2 2 }
|
|
|
|
END
|