Walter A. Boring IV 912809b0fa Add an Online check for the FC HBA
Fibre Channel devices can go into Linkdown or Offline mode after
a many times being PCI pass through to virsh domains.  We need
to make sure that the HBA we are attempting to pass through to the
virsh domain is actually in port_state="Online".  If the HBA
isn't online, then every volume attachment via that HBA will fail
100% of the time.

This patch adds a test against the requested HBA(s) and makes sure
that they are Online.  If all the requested HBA(s) are not Online,
then the script will fail.

Change-Id: Icf05bc3ed6adb842006852f1804696fc416c0d26