Site Authoring and Deployment Guide
The document contains the instructions for standing up a greenfield Airship site. This can be broken down into two high-level pieces:
- Site authoring guide(s): Describes how to craft site manifests and configs required to perform a deployment. The primary site authoring guide is for deploying Airship sites, where OpenStack is the target platform deployed on top of Airship.
- Deployment guide(s): Describes how to apply site manifests for a given site.
This document is an "all in one" site authoring guide + deployment
guide for a standard Airship deployment. For the most part, the site
authoring guidance lives within airship-seaworthy
reference
site in the form of YAML comments.
Terminology
Cloud: A platform that provides a standard set of interfaces for IaaS consumers.
OSH: (OpenStack Helm) is a collection of Helm charts used to deploy OpenStack on kubernetes.
Undercloud/Overcloud: Terms used to distinguish which cloud is deployed on top of the other. In Airship sites, OpenStack (overcloud) is deployed on top of Kubernetes (underlcoud).
Airship: A specific implementation of OpenStack Helm charts onto kubernetes, the deployment of which is the primary focus of this document.
Control Plane: From the point of view of the cloud service provider, the control plane refers to the set of resources (hardware, network, storage, etc) sourced to run cloud services.
Data Plane: From the point of view of the cloud service provider, the data plane is the set of resources (hardware, network, storage, etc.) sourced to to run consumer workloads. When used in this document, "data plane" refers to the data plane of the overcloud (OSH).
Host Profile: A host profile is a standard way of configuring a bare metal host. Encompasses items such as the number of bonds, bond slaves, physical storage mapping and partitioning, and kernel parameters.
Component Overview
Node Overview
This document refers to several types of nodes, which vary in their purpose, and to some degree in their orchestration / setup:
- Build node: This refers to the environment where configuration documents are built for your environment (e.g., your laptop)
- Genesis node: The "genesis" or "seed node" refers to a node used to get a new deployment off the ground, and is the first node built in a new deployment environment.
- Control / Controller nodes: The nodes that make up the control plane. (Note that the Genesis node will be one of the controller nodes.)
- Compute nodes / Worker Nodes: The nodes that make up the data plane
Support
Bugs may be viewed and reported at the following locations, depending on the component:
For OSH: Launchpad
Airship: Bugs may be filed using OpenStack Storyboard for specific projects in Airship group:
Hardware Prep
Disk
- Control plane server disks:
- Two-disk RAID-1 mirror for operating system
- Two-disk RAID-1 mirror for ceph journals - preferentially SSDs
- Remaining disks as JBOD for Ceph
- Data plane server disks:
- Two-disk RAID-1 mirror for operating system
- Remaining disks need to be configured according to the host profile target for each given server (e.g., RAID-10).
BIOS and IPMI
- Virtualization enabled in BIOS
- IPMI enabled in server BIOS (e.g., IPMI over LAN option enabled)
- IPMI IPs assigned, and routed to the environment you will deploy into Note: Firmware bugs related to IPMI are common. Ensure you are running the latest firmware version for your hardware. Otherwise, it is recommended to perform an iLo/iDrac reset, as IPMI bugs with long-running firmware are not uncommon.
- Set PXE as first boot device and ensure the correct NIC is selected for PXE
Network
- You have a network you can successfully PXE boot with your network topology and bonding settings (dedicated PXE interace on untagged/native VLAN in this example)
- You have (VLAN) segmented, routed networks accessible by all nodes
for:
- Management network(s) (k8s control channel)
- Calico network(s)
- Storage network(s)
- Overlay network(s)
- Public network(s)
HW Sizing and minimum requirements
Node | disk | memory | cpu |
---|---|---|---|
|
|
|
|
Genesis |
|
|
|
Control |
|
|
|
Compute |
|
|
|
- Workload driven (determined by host profile)
Establishing build node environment
On the machine you wish to use to generate deployment files, install required tooling:
sudo apt -y install docker.io git
Clone and link the required git repos as follows:
git clone https://git.openstack.org/openstack/airship-pegleg git clone https://git.openstack.org/openstack/airship-treasuremap
Building Site documents
This section goes over how to put together site documents according to your specific environment, and generate the initial Promenade bundle needed to start the site deployment.
Preparing deployment documents
In its current form, pegleg provides an organized structure for YAML
elements, in order to separate common site elements (i.e.,
global
folder) from unique site elements (i.e.,
site
folder).
To gain a full understanding of the pegleg strutcure, it is highly recommended to read pegleg documentation on this here.
The airship-seaworthy
site may be used as reference
site. It is the principal pipeline for integration and continuous
deployment testing of Airship.
Change directory to the airship-treasuremap/site
folder
and copy the airship-seaworthy
site as follows:
NEW_SITE=mySite # replace with the name of your site
cd airship-treasuremap/site
cp -r airship-seaworthy $NEW_SITE
Remove airship-seaworthy
specific certificates.
rm -rf airship-treasuremap/site/airship-seaworthy/secrets/certificates/certificates.yaml
You will then need to manually make changes to these files. These site manifests are heavily commented to explain parameters, and importantly identify all of the parameters that need to change when authoring a new site.
These areas which must be updated for a new site are flagged with the
label NEWSITE-CHANGEME
in YAML commentary. Search for all
instances of NEWSITE-CHANGEME
in your new site definition,
and follow the instructions that accompany the tag in order to make all
needed changes to author your new Airship site.
Because some files depend on (or will repeat) information from others, the order in which you should build your site files is as follows:
- site/$NEW_SITE/networks/physical/networks.yaml
- site/$NEW_SITE/baremetal/nodes.yaml
- site/$NEW_SITE/networks/common-addresses.yaml
- site/$NEW_SITE/pki/pki-catalog.yaml
- All other site files
Control Plane Ceph Cluster Notes
Environment Ceph parameters for the control plane are located in:
site/$NEW_SITE/software/charts/ucp/ceph/ceph.yaml
Setting highlights:
- data/values/conf/storage/osd[*]/data/location: The block device that will be formatted by the Ceph chart and used as a Ceph OSD disk
- data/values/conf/storage/osd[*]/journal/location: The directory backing the ceph journal used by this OSD. Refer to the journal paradigm below.
- data/values/conf/pool/target/osd: Number of OSD disks on each node
Assumptions:
- Ceph OSD disks are not configured for any type of RAID (i.e., they are configured as JBOD if connected through a RAID controller). (If RAID controller does not support JBOD, put each disk in its own RAID-0 and enable RAID cache and write-back cache if the RAID controller supports it.)
- Ceph disk mapping, disk layout, journal and OSD setup is the same across Ceph nodes, with only their role differing. Out of the 4 control plane nodes, we expect to have 3 actively participating in the Ceph quorom, and the remaining 1 node designated as a standby Ceph node which uses a different control plane profile (cp_-secondary) than the other three (cp_-primary).
- If doing a fresh install, disk are unlabeled or not labeled from a previous Ceph install, so that Ceph chart will not fail disk initialization
This document covers two Ceph journal deployment paradigms:
- Servers with SSD/HDD mix (disregarding operating system disks).
- Servers with no SSDs (disregarding operating system disks). In other words, exclusively spinning disk HDDs available for Ceph.
If you have an operating system available on the target hardware, you can determine HDD and SSD layout with:
lsblk -d -o name,rota
where a rota
(rotational) value of 1
indicates a spinning HDD, and where a value of 0
indicates
non-spinning disk (i.e. SSD). (Note - Some SSDs still report a value of
1
, so it is best to go by your server specifications).
In case #1, the SSDs will be used for journals and the HDDs for OSDs.
For OSDs, pass in the whole block device (e.g.,
/dev/sdd
), and the Ceph chart will take care of disk
partitioning, formatting, mounting, etc.
For journals, divide the number of journal disks as evenly as possible between the OSD disks. We will also use the whole block device, however we cannot pass that block device to the Ceph chart like we can for the OSD disks.
Instead, the journal devices must be already partitioned, formatted, and mounted prior to Ceph chart execution. This should be done by MaaS as part of the Drydock host-profile being used for control plane nodes.
Consider the follow example where:
- /dev/sda is an operating system RAID-1 device (SSDs for OS root)
- /dev/sdb is an operating system RAID-1 device (SSDs for ceph journal)
- /dev/sd[cdef] are HDDs
Then, the data section of this file would look like:
data:
values:
conf:
storage:
osd:
- data:
type: block-logical
location: /dev/sdd
journal:
type: directory
location: /var/lib/openstack-helm/ceph/journal/journal-sdd
- data:
type: block-logical
location: /dev/sde
journal:
type: directory
location: /var/lib/openstack-helm/ceph/journal/journal-sde
- data:
type: block-logical
location: /dev/sdf
journal:
type: directory
location: /var/lib/openstack-helm/ceph/journal/journal-sdf
- data:
type: block-logical
location: /dev/sdg
journal:
type: directory
location: /var/lib/openstack-helm/ceph/journal/journal-sdg
pool:
target:
osd: 4
where the following mount is setup by MaaS via Drydock host profile for the control-plane nodes:
/dev/sdb is mounted to /var/lib/openstack-helm/ceph/journal
In case #2, Ceph best practice is to allocate journal space on all OSD disks. The Ceph chart assumes this partitioning has been done beforehand. Ensure that your control plane host profile is partitioning each disk between the Ceph OSD and Ceph journal, and that it is mounting the journal partitions. (Drydock will drive these disk layouts via MaaS provisioning). Note the mountpoints for the journals and the partition mappings. Consider the following example where:
- /dev/sda is the operating system RAID-1 device
- /dev/sd[bcde] are HDDs
Then, the data section of this file will look similar to the following:
data:
values:
conf:
storage:
osd:
- data:
type: block-logical
location: /dev/sdb2
journal:
type: directory
location: /var/lib/openstack-helm/ceph/journal0/journal-sdb
- data:
type: block-logical
location: /dev/sdc2
journal:
type: directory
location: /var/lib/openstack-helm/ceph/journal1/journal-sdc
- data:
type: block-logical
location: /dev/sdd2
journal:
type: directory
location: /var/lib/openstack-helm/ceph/journal2/journal-sdd
- data:
type: block-logical
location: /dev/sde2
journal:
type: directory
location: /var/lib/openstack-helm/ceph/journal3/journal-sde
pool:
target:
osd: 4
where the following mounts are setup by MaaS via Drydock host profile for the control-plane nodes:
/dev/sdb1 is mounted to /var/lib/openstack-helm/ceph/journal0
/dev/sdc1 is mounted to /var/lib/openstack-helm/ceph/journal1
/dev/sdd1 is mounted to /var/lib/openstack-helm/ceph/journal2
/dev/sde1 is mounted to /var/lib/openstack-helm/ceph/journal3
Update Passphrases
Replace passphrases under
site/airship-seaworthy/secrets/passphrases/
with random
generated ones (e.g. openssl rand -hex 10
).
Manifest linting and combining layers
After constituent YAML configurations are finalized, use Pegleg to lint your manifests, and resolve any issues that result from linting before proceeding:
sudo airship-pegleg/tools/pegleg.sh lint \
-p airship-treasuremap
Note: P001
and P003
linting errors are
expected for missing certificates, as they are not generated until the
next section. You may suppress these warnings by appending
-x P001 -x P003
to the lint command.
Next, use pegleg to perform the merge that will yield the combined global + site type + site YAML:
sudo sh airship-pegleg/tools/pegleg.sh site \
-p airship-treasuremap \
collect $NEW_SITE
Perform a visual inspection of the output. If any errors are
discovered, you may fix your manifests and re-run the lint
and collect
commands.
After you have an error-free output, save the resulting YAML as follows:
mkdir -p ~/${NEW_SITE}_collected
sudo airship-pegleg/tools/pegleg.sh site \
-p airship-treasuremap \
collect $NEW_SITE -s ${NEW_SITE}_collected
It is this output which will be used in subsequent steps.
Lastly, you should also perform a render
on the
documents. The resulting render from Pegleg will not be used as input in
subsequent steps, but is useful for understanding what the document will
look like once Deckhand has performed all substitutions, replacements,
etc. This is also useful for troubleshooting, and addressing any
Deckhand errors prior to submitting via Shipyard:
sudo airship-pegleg/tools/pegleg.sh site \
-p airship-treasuremap \
render $NEW_SITE
Inspect the rendered document for any errors. If there are errors, address them in your manifests and re-run this section of the document.
Building the Promenade bundle
Clone the Promenade repo, if not already cloned:
git clone https://github.com/openstack/airship-promenade
Refer to the data/charts/ucp/promenade/reference
field
in
airship-treasuremap/global/v4.0/software/config/versions.yaml
.
If this is a pinned reference (i.e., any reference that's not
master
), then you should checkout the same version of the
Promenade repository. For example, if the Promenade reference was
86c3c11...
in the versions file, checkout the same version
of the Promenade repo which was cloned previously:
(cd airship-promenade && git checkout 86c3c11)
Likewise, before running the simple-deployment.sh
script, you should refer to the
data/images/ucp/promenade/promenade
field in
~/airship-treasuremap/global/v4.0/software/config/versions.yaml
.
If there is a pinned reference (i.e., any image reference that's not
latest
), then this reference should be used to set the
IMAGE_PROMENADE
environment variable. For example, if the
Promenade image was pinned to
quay.io/airshipit/promenade:d30397f...
in the versions
file, then export the previously mentioned environment variable like
so:
export IMAGE_PROMENADE=quay.io/airshipit/promenade:d30397f...
Now, create an output directory for Promenade bundles and run the
simple-deployment.sh
script:
mkdir ${NEW_SITE}_bundle
sudo airship-promenade/tools/simple-deployment.sh ${NEW_SITE}_collected ${NEW_SITE}_bundle
Estimated runtime: About 1 minute
After the bundle has been successfully created, copy the generated certificates into the security folder. Ex:
mkdir -p airship-treasuremap/site/${NEW_SITE}/secrets/certificates
sudo cp ${NEW_SITE}_bundle/certificates.yaml \
airship-treasuremap/site/${NEW_SITE}/secrets/certificates/certificates.yaml
Genesis node
Initial setup
Before starting, ensure that the BIOS and IPMI settings match those stated previously in this document. Also ensure that the hardware RAID is setup for this node per the control plane disk configuration stated previously in this document.
Then, start with a manual install of Ubuntu 16.04 on the node you wish to use to seed the rest of your environment standard Ubuntu ISO. Ensure to select the following:
- UTC timezone
- Hostname that matches the Genesis hostname given in
/data/genesis/hostname
inairship-treasuremap/site/$NEW_SITE/networks/common-addresses.yaml
. - At the
Partition Disks
screen, selectManual
so that you can setup the same disk partitioning scheme used on the other control plane nodes that will be deployed by MaaS. Select the first logical device that corresponds to one of the RAID-1 arrays already setup in the hardware controller. On this device, setup partitions matching those defined for thebootdisk
in your control plane host profile found inairship-treasuremap/site/$NEW_SITE/profiles/host
. (e.g., 30G for /, 1G for /boot, 100G for /var/log, and all remaining storage for /var). Note that the volume size syntax looking like>300g
in Drydock means that all remaining disk space is allocated to this volume, and that that volume needs to be at least 300G in size. - When you get to the prompt, "How do you want to manage upgrades on this system?", choose "No automatic updates" so that packages are only updated at the time of our choosing (e.g. maintenance windows).
- Ensure the grub bootloader is also installed to the same logical device as in the previous step (this should be default behavior).
After installation, ensure the host has outbound internet access and
can resolve public DNS entries (e.g., nslookup google.com
,
curl https://www.google.com
).
Ensure that the deployed Genesis hostname matches the hostname in
data/genesis/hostname
in
airship-treasuremap/site/$NEW_SITE/networks/common-addresses.yaml
.
If it does not match, then either change the hostname of the node to
match the configuration documents, or re-generate the configuration with
the correct hostname. In order to change the hostname of the deployed
node, you may run the following:
sudo hostname $NEW_HOSTNAME
sudo sh -c "echo $NEW_HOSTNAME > /etc/hostname"
sudo vi /etc/hosts # Anywhere the old hostname appears in the file, replace
# with the new hostname
Or to regenerate manifests, re-run the previous two sections with the after updating the genesis hostname in the site definition.
Installing matching kernel version
Install the same kernel version on the Genesis host that MaaS will use to deploy new baremetal nodes.
In order to do this, first you must determine the kernel version that
will be deployed to those nodes. Start by looking at the host profile
definition used to deploy other control plane nodes by searching for
control-plane: enabled
. Most likely this will be a file
under global/v4.0/profiles/host
. In this file, find the
kernel info -e.g.:
platform:
image: 'xenial'
kernel: 'hwe-16.04'
In this case, it is the hardware enablement kernel for 16.04. To find
the exact kernel version that will be deployed, we must look into the
simple-stream image cache that will be used by MaaS to deploy nodes
with. Locate the data/images/ucp/maas/maas_cache
key in
within
airship-treasuremap/global/v4.0/software/config/versions.yaml
.
This is the image that you will need to fetch, using a node with docker
installed that has access and can reach the site/location hosting the
image. For example, from the build node, the command
would take the form:
sudo docker pull YOUR_SSTREAM_IMAGE
Then, create a container from that image:
cd ~
sudo sh -c "$(docker images | grep sstream-cache | head -1 | awk '{print $1}' > image_name)"
sudo docker create --name sstream $(cat image_name)
Then use the container ID returned from the last command as follows:
sudo docker start sstream
sudo docker exec -it sstream /bin/bash
In the container, install the file
package. Define any
proxy environment variables needed for your environment to reach public
ubuntu package repos, then run:
apt -y install file
In the container, cd
to the following location
(substituting for the platform image and platform kernel identified in
the host profile previously, and choosing the folder corresponding to
the most current date if more than one are available) and run the
file
command on the boot-kernel
file:
cd /var/www/html/maas/images/ephemeral-v3/daily/PLATFORM_IMAGE/amd64/LATEST_DATE/PLATFORM_KERNEL/generic
file boot-kernel
This will produce the complete kernel version. E.g.:
Linux kernel x86 boot executable bzImage, version 4.13.0-43-generic (buildd@lcy01-amd64-029) #48~16.04.1-Ubuntu S, RO-rootFS, swap_dev 0x7, Normal VGA
In this example, the kernel version is
4.13.0-43-generic
. Now install the matching kernel on the
Genesis host (make sure to run on Genesis host, not the build host):
sudo apt -y install 4.13.0-43-generic
Check the installed packages on the genesis host with
dpkg --list
. If there are any later kernel versions
installed, remove them with sudo apt remove
, so that the
newly install kernel is the latest available.
Lastly if you wish to cleanup your build node, you may run the following:
exit # (to quit the container)
cd ~
sudo docker stop sstream
sudo docker rm sstream
sudo docker image rm $(cat image_name)
sudo rm image_name
Install ntpdate/ntp
Install and run ntpdate, to ensure a reasonably sane time on genesis host before proceeding:
sudo apt -y install ntpdate
sudo ntpdate ntp.ubuntu.com
If your network policy does not allow time sync with external time
sources, specify a local NTP server instead of using
ntp.ubuntu.com
.
Then, install the NTP client:
sudo apt -y install ntp
Add the list of NTP servers specified in
data/ntp/servers_joined
in file
airship-treasuremap/site/$NEW_SITE/networks/common-address.yaml
to /etc/ntp.conf
as follows:
pool NTP_SERVER1 iburst
pool NTP_SERVER2 iburst
(repeat for each NTP server with correct NTP IP or FQDN)
Then, restart the NTP service:
sudo service ntp restart
If you cannot get good time to your selected time servers, consider using alternate time sources for your deployment.
Disable the apparmor profile for ntpd:
sudo ln -s /etc/apparmor.d/usr.sbin.ntpd /etc/apparmor.d/disable/
sudo apparmor_parser -R /etc/apparmor.d/usr.sbin.ntpd
This prevents an issue with the MaaS containers, which otherwise get permission denied errors from apparmor when the MaaS container tries to leverage libc6 for /bin/sh when MaaS container ntpd is forcefully disabled.
Setup Ceph Journals
Until genesis node reprovisioning is implemented, it is necessary to manually perform host-level disk partitioning and mounting on the genesis node, for activites that would otherwise have been addressed by a bare metal node provision via Drydock host profile data by MaaS.
Assuming your genesis HW matches the HW used in your control plane
host profile, you should manually apply to the genesis node the same
Ceph partitioning (OSDs & journals) and formatting + mounting
(journals only) as defined in the control plane host profile. See
airship-treasuremap/global/v4.0/profiles/host/base_control_plane.yaml
.
For example, if we have a journal SSDs /dev/sdb
on the
genesis node, then use the cfdisk
tool to format it:
sudo cfdisk /dev/sdb
Then:
- Select
gpt
label for the disk - Select
New
to create a new partition - If scenario #1 applies in site/$NEW_SITE/software/charts/ucp/ceph/ceph.yaml_, then accept default partition size (entire disk). If scenario #2 applies, then only allocate as much space as defined in the journal disk partitions mounted in the control plane host profile.
- Select
Write
option to commit changes, thenQuit
- If scenario #2 applies, create a second partition that takes up all
of the remaining disk space. This will be used as the OSD partition
(
/dev/sdb2
).
Install package to format disks with XFS:
sudo apt -y install xfsprogs
Then, construct an XFS filesystem on the journal partition with XFS:
sudo mkfs.xfs /dev/sdb1
Create a directory as mount point for /dev/sdb1
to match
those defined in the same host profile ceph journals:
sudo mkdir -p /var/lib/ceph/cp
Use the blkid
command to get the UUID for
/dev/sdb1
, then populate /etc/fstab
accordingly. Ex:
sudo sh -c 'echo "UUID=01234567-ffff-aaaa-bbbb-abcdef012345 /var/lib/ceph/cp xfs defaults 0 0" >> /etc/fstab'
Repeat all preceeding steps in this section for each journal device in the Ceph cluster. After this is completed for all journals, mount the partitions:
sudo mount -a
Promenade bootstrap
Copy the ${NEW_SITE}_bundle
and
${NEW_SITE}_collected
directories from the build node to
the genesis node, into the home directory of the user there (e.g.,
/home/ubuntu
). Then, run the following script as sudo on
the genesis node:
cd ${NEW_SITE}_bundle
sudo ./genesis.sh
Estimated runtime: 40m
Following completion, run the validate-genesis.sh
script
to ensure correct provisioning of the genesis node:
cd ${NEW_SITE}_bundle
sudo ./validate-genesis.sh
Estimated runtime: 2m
Deploy Site with Shipyard
Start by cloning the shipyard repository to the Genesis node:
git clone https://github.com/openstack/airship-shipyard
Refer to the data/charts/ucp/shipyard/reference
field in
airship-treasuremap/global/v4.0/software/config/versions.yaml
.
If this is a pinned reference (i.e., any reference that's not
master
), then you should checkout the same version of the
Shipyard repository. For example, if the Shipyard reference was
7046ad3...
in the versions file, checkout the same version
of the Shipyard repo which was cloned previously:
(cd airship-shipyard && git checkout 7046ad3)
Likewise, before running the deckhand_load_yaml.sh
script, you should refer to the
data/images/ucp/shipyard/shipyard
field in
airship-treasuremap/global/v4.0/software/config/versions.yaml
.
If there is a pinned reference (i.e., any image reference that's not
latest
), then this reference should be used to set the
SHIPYARD_IMAGE
environment variable. For example, if the
Shipyard image was pinned to
quay.io/airshipit/shipyard@sha256:dfc25e1...
in the
versions file, then export the previously mentioned environment
variable:
export SHIPYARD_IMAGE=quay.io/airshipit/shipyard@sha256:dfc25e1...
Export valid login credentials for one of the Airship Keystone users
defined for the site. Currently there is no authorization checks in
place, so the credentials for any of the site-defined users will work.
For example, we can use the shipyard
user, with the
password that was defined in
airship-treasuremap/site/$NEW_SITE/secrets/passphrases/ucp_shipyard_keystone_password.yaml
.
Ex:
export OS_USERNAME=shipyard
export OS_PASSWORD=46a75e4...
(Note: Default auth variables are defined here, and should otherwise be correct, barring any customizations of these site parameters).
Next, run the deckhand_load_yaml.sh script as follows:
sudo airship-shipyard/tools/deckhand_load_yaml.sh ${NEW_SITE} ${NEW_SITE}_collected
Estimated runtime: 3m
Now deploy the site with shipyard:
sudo airship-shipyard/tools/deploy_site.sh
Estimated runtime: 1h30m
The message Site Successfully Deployed
is the expected
output at the end of a successful deployment. In this example, this
means that Airship and OSH should be fully deployed.
Disable password-based login on Genesis
Before proceeding, verify that your SSH access to the Genesis node is working with your SSH key (i.e., not using password-based authentication).
Then, disable password-based SSH authentication on Genesis in
/etc/ssh/sshd_config
by uncommenting the
PasswordAuthentication
and setting its value to
no
. Ex:
PasswordAuthentication no
Then, restart the ssh service: