aodh/doc/source/measurements.rst
Koert van der Veer b27ac819fb Implemented metering for Cinder's snapshots
Cinder already publishes the required notifications, but Ceilometer
wasn't recording them. This patch fixes that.

Closes-Bug: #1316670

Change-Id: I53532d1833db2f22a803bf77e548f5d3b095a30f
2014-05-22 19:57:04 +02:00

325 lines
20 KiB
ReStructuredText

..
Copyright 2012 New Dream Network (DreamHost)
Licensed under the Apache License, Version 2.0 (the "License"); you may
not use this file except in compliance with the License. You may obtain
a copy of the License at
http://www.apache.org/licenses/LICENSE-2.0
Unless required by applicable law or agreed to in writing, software
distributed under the License is distributed on an "AS IS" BASIS, WITHOUT
WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the
License for the specific language governing permissions and limitations
under the License.
.. _measurements:
==============
Measurements
==============
Three type of meters are defined in ceilometer:
.. index::
double: meter; cumulative
double: meter; gauge
double: meter; delta
========== ==============================================================================
Type Definition
========== ==============================================================================
Cumulative Increasing over time (instance hours)
Gauge Discrete items (floating IPs, image uploads) and fluctuating values (disk I/O)
Delta Changing over time (bandwidth)
========== ==============================================================================
Units
=====
1. Whenever a volume is to be measured, SI approved units and their
approved symbols or abbreviations should be used. Information units
should be expressed in bits ('b') or bytes ('B').
2. For a given meter, the units should NEVER, EVER be changed.
3. When the measurement does not represent a volume, the unit
description should always described WHAT is measured (ie: apples,
disk, routers, floating IPs, etc.).
4. When creating a new meter, if another meter exists measuring
something similar, the same units and precision should be used.
5. Meters and samples should always document their units in Ceilometer (API
and Documentation) and new sampling code should not be merged without the
appropriate documentation.
============ ======== ============== =======================
Dimension Unit Abbreviations Note
============ ======== ============== =======================
None N/A Dimension-less variable
Volume byte B
Time seconds s
============ ======== ============== =======================
Here are the meter types by components that are currently implemented:
Compute (Nova)
==============
All meters are related to the guest machine, not the host.
============================= ===== ========= ======== ======== ========== ==================================================================
Name Type* Unit Resource Origin** Support*** Note
============================= ===== ========= ======== ======== ========== ==================================================================
instance g instance inst ID both 1, 2, 3 Existence of instance
instance:<type> g instance inst ID both 1, 2, 3 Existence of instance <type> (openstack types)
memory g MB inst ID n 1, 2 Volume of RAM allocated in MB
memory.usage g MB inst ID p 3 Volume of RAM used in MB
cpu c ns inst ID p 1, 2 CPU time used
cpu_util g % inst ID p 1, 2, 3 Average CPU utilisation
vcpus g vcpu inst ID n 1, 2 Number of VCPUs
disk.read.requests c request inst ID p 1, 2 Number of read requests
disk.read.requests.rate g request/s inst ID p 1, 2, 3 Average rate of read requests per second
disk.write.requests c request inst ID p 1, 2 Number of write requests
disk.write.requests.rate g request/s inst ID p 1, 2, 3 Average rate of write requests per second
disk.read.bytes c B inst ID p 1, 2 Volume of reads in B
disk.read.bytes.rate g B/s inst ID p 1, 2, 3 Average rate of reads in B per second
disk.write.bytes c B inst ID p 1, 2 Volume of writes in B
disk.write.bytes.rate g B/s inst ID p 1, 2, 3 Average volume of writes in B per second
disk.root.size g GB inst ID n 1, 2 Size of root disk in GB
disk.ephemeral.size g GB inst ID n 1, 2 Size of ephemeral disk in GB
network.incoming.bytes c B iface ID p 1, 2 Number of incoming bytes on a VM network interface
network.incoming.bytes.rate g B/s iface ID p 1, 2, 3 Average rate per sec of incoming bytes on a VM network interface
network.outgoing.bytes c B iface ID p 1, 2 Number of outgoing bytes on a VM network interface
network.outgoing.bytes.rate g B/s iface ID p 1, 2, 3 Average rate per sec of outgoing bytes on a VM network interface
network.incoming.packets c packet iface ID p 1, 2 Number of incoming packets on a VM network interface
network.incoming.packets.rate g packet/s iface ID p 1, 2, 3 Average rate per sec of incoming packets on a VM network interface
network.outgoing.packets c packet iface ID p 1, 2 Number of outgoing packets on a VM network interface
network.outgoing.packets.rate g packet/s iface ID p 1, 2, 3 Average rate per sec of outgoing packets on a VM network interface
============================= ===== ========= ======== ======== ========== ==================================================================
::
Legend:
*
[g]: gauge
[c]: cumulative
**
[p]: pollster
[n]: notification
***
[1]: Libvirt support
[2]: HyperV support
[3]: Vsphere support
Contributors are welcome to extend other virtualization backends' meters
or complete the existing ones.
The meters below are related to the host machine.
.. note::
By default, Nova will not collect the following meters related to the host
compute node machine. Nova option 'compute_monitors = ComputeDriverCPUMonitor'
should be set in nova.conf to enable meters.
=============================== ========== ========= ======== ============ ========================
Name Type Unit Resource Origin Note
=============================== ========== ========= ======== ============ ========================
compute.node.cpu.frequency Gauge MHz host ID notification CPU frequency
compute.node.cpu.kernel.time Cumulative ns host ID notification CPU kernel time
compute.node.cpu.idle.time Cumulative ns host ID notification CPU idle time
compute.node.cpu.user.time Cumulative ns host ID notification CPU user mode time
compute.node.cpu.iowait.time Cumulative ns host ID notification CPU I/O wait time
compute.node.cpu.kernel.percent Gauge % host ID notification CPU kernel percentage
compute.node.cpu.idle.percent Gauge % host ID notification CPU idle percentage
compute.node.cpu.user.percent Gauge % host ID notification CPU user mode percentage
compute.node.cpu.iowait.percent Gauge % host ID notification CPU I/O wait percentage
compute.node.cpu.percent Gauge % host ID notification CPU utilization
=============================== ========== ========= ======== ============ ========================
Network (Neutron)
=================
======================== ========== ======== ======== ============ ======================================================
Name Type Unit Resource Origin Note
======================== ========== ======== ======== ============ ======================================================
network Gauge network netw ID notification Existence of network
network.create Delta network netw ID notification Creation requests for this network
network.update Delta network netw ID notification Update requests for this network
subnet Gauge subnet subnt ID notification Existence of subnet
subnet.create Delta subnet subnt ID notification Creation requests for this subnet
subnet.update Delta subnet subnt ID notification Update requests for this subnet
port Gauge port port ID notification Existence of port
port.create Delta port port ID notification Creation requests for this port
port.update Delta port port ID notification Update requests for this port
router Gauge router rtr ID notification Existence of router
router.create Delta router rtr ID notification Creation requests for this router
router.update Delta router rtr ID notification Update requests for this router
ip.floating Gauge ip ip ID both Existence of floating ip
ip.floating.create Delta ip ip ID notification Creation requests for this floating ip
ip.floating.update Delta ip ip ID notification Update requests for this floating ip
======================== ========== ======== ======== ============ ======================================================
Image (Glance)
==============
======================== ========== ======= ======== ============ =======================================================
Name Type Unit Resource Origin Note
======================== ========== ======= ======== ============ =======================================================
image Gauge image image ID both Image polling -> it (still) exists
image.size Gauge B image ID both Uploaded image size
image.update Delta image image ID notification Number of update on the image
image.upload Delta image image ID notification Number of upload of the image
image.delete Delta image image ID notification Number of delete on the image
image.download Delta B image ID notification Image is downloaded
image.serve Delta B image ID notification Image is served out
======================== ========== ======= ======== ============ =======================================================
Volume (Cinder)
===============
======================== ========== ======== ======== ============ =======================================================
Name Type Unit Resource Origin Note
======================== ========== ======== ======== ============ =======================================================
volume Gauge volume vol ID notification Existence of volume
volume.size Gauge GB vol ID notification Size of volume
snapshot Gauge snapshot snap ID notification Existence of snapshot
snapshot.size Gauge GB snap ID notification Size of snapshot's volume
======================== ========== ======== ======== ============ =======================================================
Make sure Cinder is properly configured first: see :ref:`installing_manually`.
Object Storage (Swift)
======================
=============================== ========== ========== =========== ============ ==========================================
Name Type Unit Resource Origin Note
=============================== ========== ========== =========== ============ ==========================================
storage.objects Gauge object store ID pollster Number of objects
storage.objects.size Gauge B store ID pollster Total size of stored objects
storage.objects.containers Gauge container store ID pollster Number of containers
storage.objects.incoming.bytes Delta B store ID notification Number of incoming bytes
storage.objects.outgoing.bytes Delta B store ID notification Number of outgoing bytes
storage.api.request Delta request store ID notification Number of API requests against swift
storage.containers.objects Gauge object str ID/cont pollster Number of objects in container
storage.containers.objects.size Gauge B str ID/cont pollster Total size of stored objects in container
=============================== ========== ========== =========== ============ ==========================================
In order to use storage.objects.incoming.bytes and storage.outgoing.bytes, one must configure
Swift as described in :ref:`installing_manually`. Note that they may not be
updated right after an upload/download, since Swift takes some time to update
the container properties.
Orchestration (Heat)
====================
=============================== ========== ========== =========== ============ ==========================================
Name Type Unit Resource Origin Note
=============================== ========== ========== =========== ============ ==========================================
stack.create Delta stack stack ID notification Creation requests for a stack successful
stack.update Delta stack stack ID notification Updating requests for a stack successful
stack.delete Delta stack stack ID notification Deletion requests for a stack successful
stack.resume Delta stack stack ID notification Resuming requests for a stack successful
stack.suspend Delta stack stack ID notification Suspending requests for a stack successful
=============================== ========== ========== =========== ============ ==========================================
To enable Heat notifications configure Heat as described in :ref:`installing_manually`.
Energy (Kwapi)
==============
========================== ========== ========== ======== ========= ==============================================
Name Type Unit Resource Origin Note
========================== ========== ========== ======== ========= ==============================================
energy Cumulative kWh probe ID pollster Amount of energy
power Gauge W probe ID pollster Power consumption
========================== ========== ========== ======== ========= ==============================================
Network (From SDN Controller)
=============================
These meters based on OpenFlow Switch metrics.
In order to enable these meters, each driver needs to be configured.
================================= ========== ====== ========= ======== ==============================
Meter Type Unit Resource Origin Note
================================= ========== ====== ========= ======== ==============================
switch Gauge switch switch ID pollster Existence of switch
switch.port Gauge port switch ID pollster Existence of port
switch.port.receive.packets Cumulative packet switch ID pollster Received Packets
switch.port.transmit.packets Cumulative packet switch ID pollster Transmitted Packets
switch.port.receive.bytes Cumulative B switch ID pollster Received Bytes
switch.port.transmit.bytes Cumulative B switch ID pollster Transmitted Bytes
switch.port.receive.drops Cumulative packet switch ID pollster Receive Drops
switch.port.transmit.drops Cumulative packet switch ID pollster Transmit Drops
switch.port.receive.errors Cumulative packet switch ID pollster Receive Errors
switch.port.transmit.errors Cumulative packet switch ID pollster Transmit Errors
switch.port.receive.frame_error Cumulative packet switch ID pollster Receive Frame Alignment Errors
switch.port.receive.overrun_error Cumulative packet switch ID pollster Receive Overrun Errors
switch.port.receive.crc_error Cumulative packet switch ID pollster Receive CRC Errors
switch.port.collision.count Cumulative count switch ID pollster Collisions
switch.table Gauge table switch ID pollster Duration of Table
switch.table.active.entries Gauge entry switch ID pollster Active Entries
switch.table.lookup.packets Gauge packet switch ID pollster Packet Lookups
switch.table.matched.packets Gauge packet switch ID pollster Packet Matches
switch.flow Gauge flow switch ID pollster Duration of Flow
switch.flow.duration.seconds Gauge s switch ID pollster Duration(seconds)
switch.flow.duration.nanoseconds Gauge ns switch ID pollster Duration(nanoseconds)
switch.flow.packets Cumulative packet switch ID pollster Received Packets
switch.flow.bytes Cumulative B switch ID pollster Received Bytes
================================= ========== ====== ========= ======== ==============================
Dynamically retrieving the Meters via ceilometer client
=======================================================
To retrieve the available meters that can be queried given the actual
resource instances available, use the ``meter-list`` command:
::
$ ceilometer meter-list -s openstack
+------------+-------+--------------------------------------+---------+----------------------------------+
| Name | Type | Resource ID | User ID | Project ID |
+------------+-------+--------------------------------------+---------+----------------------------------+
| image | gauge | 09e84d97-8712-4dd2-bcce-45970b2430f7 | | 57cf6d93688e4d39bf2fe3d3c03eb326 |
Naming convention
=================
If you plan on adding meters, please follow the convention below:
1. Always use '.' as separator and go from least to most discriminant word.
For example, do not use ephemeral_disk_size but disk.ephemeral.size
2. When a part of the name is a variable, it should always be at the end and start with a ':'.
For example do not use <type>.image but image:<type>, where type is your variable name.
3. If you have any hesitation, come and ask in #openstack-ceilometer
User-defined sample metadata for Nova
=========================================
Users are allowed to add additional metadata to samples of nova meter.
These additional metadata are stored in 'resource_metadata.user_metadata.*' of the sample.
To do so, users should add nova user metadata prefixed with 'metering.':
::
$ nova boot --meta metering.custom_metadata=a_value my_vm
Note: The name of the metadata shouldn't exceed 256 characters otherwise it will be cut off.
Also, if it has '.', this will be replaced by a '_' in ceilometer.
User-defined sample metadata for Swift
==========================================
It's possible to add additional metadata to sample of Swift meter as well.
You might specify headers whose values will be stored in resource_metadata as
'resource_metadata.http_header_$name', where $name is a name of the header with
'-' replaced by '_'.
This is done using 'metadata_headers' option in middleware configuration,
refer to :ref:`installing_manually` for details.
For example, this could be used to distinguish external and internal users. You'd
have to implement a custom Swift middleware that sets a proper header and just add
it to metadata_headers.