cinder-specs/specs/kilo/iscsi-multipath-enhancement.rst
Mike Perez 8ca13afc49 Introduce use case section
This will now require a separate section "Use Cases". This was
originally within "Problem description", but use cases seems to be
missed when it was filled out. This will hopefully improve spec
submission.

Change-Id: I3615ca5ff5c46851e682739a8343242e2f1b0a8d
2015-04-15 22:20:56 -07:00

6.7 KiB

Enhance iSCSI multipath support

Include the URL of your launchpad blueprint:

https://blueprints.launchpad.net/cinder/+spec/enhance-iscsi-multipath

This spec proposes to enhance iSCSI multipath support by defining the way to tell multiple iSCSI portals/iqns/luns to access a volume (LU) to Nova.

Problem description

Currently, nova-compute supports multipath for iSCSI volume data path. It depends on response to targets discovery of from the main iSCSI portal, expecting multiple portal addresses are contained.

However, some arrays only respond to discovery with a single portal address, even if secondary portals are available. In this case, nova-compute cannot know secondary portals and corresponding iSCSI target IQN, so nova-compute cannot establish multiple sessions for the target(s). To enable nova-compute to login to secondary portals, cinder should tell the secondary portal addresses and corresponding target iqns/luns.

Telling secondary portal addresses and iqns/luns is also useful for arrays which can respond to discovery with multiple portals addresses and IQNs, since compute can access to the volume via secondary portals even when the main portal is unaccessible due to network trouble. (Note that compute should attach the volume via multipath device "dm-X" so that the session to the main portal can be re-established when the network is recovered.)

Use Cases

Proposed change

If nova-compute can support multipath for iSCSI (that is, if multipathd is installed and CONF.libvirt.iscsi_use_multipath is set True), nova-compute should call Cinder initialize_connection API with a new 'multipath=True' optional key in 'connector' dictionary. This parameter is passed to the backend driver so that the driver can export a volume to multiple ports.

When the 'multipath=True' is specified, 'connection_info' of the API response will contain multiple portal addresses and corresponding target iqns/luns. Current 'target_portal'/'target_iqn'/'target_lun' parameters will be replaced with 'target_portals'/'target_iqns'/'target_luns' which have a list of the addresses of the iSCSI portals and the corresponding iqn/lun to each portal. When nova-compute recognizes these parameters, it will log into every portal address/target/lun. When the backend doesn't support (or not configured to support) multipath, the driver may return current 'target_portal'/ 'target_iqn'/'target_lun' set.

When the 'multipath=False' is specified or the key is omitted, the API must return 'target_portal'/'target_iqn'/'target_lun' set.

This change must be applied also to cinder/brick/initiator.

Alternatives

None

Data model impact

None

REST API impact

'os-initialize_connection' volume action API will take new optional parameter 'multipath' in the connector argument, that means the connector can handle multipath to iSCSI volumes.

When the 'multipath=True' is specified, 'os-initialize_connection' volume action API respond with 'target_portals'/'target_iqns'/'target_luns' in 'connection_info' which contain a list of portal IP address:port pairs, a list of secondary iqn's and lun's corresponding to each portal address.

For example:

{"connection_info": {"driver_volume_type": "iscsi", ...
"data": {"target_portals": ["10.0.1.2:3260",

"10.0.2.2:3260"], "target_iqns": [ "iqn.2014-2.org.example:vol1-1", "iqn.2014-2.org.example:vol1-2"], "target_luns": [1, 2], ...}}}

In this case, "iqn.2014-2.org.example:vol1-1", lun=1 is for portal "10.0.1.2:3260", and "iqn.2014-2.org.example:vol1-2", lun=2 is for portal "10.0.2.2:3260".

Security impact

None

Note that if any CHAP credentials are provided in connection_info, they must be applied on the all target_portals.

Notifications impact

None

Other end user impact

None

Performance Impact

Since nova-compute can omit discovery query to find multiple portals and targets, this change may make volume-attach/detach operations faster.

Other deployer impact

Backend driver may have additional settings to enable iSCSI portal multipath. For example, to utilize this feature in iSCSI LVM driver, we needs to specify a list of secondary IP addresses of the cinder-volume node where iSCSI targets run on.

Developer impact

If drivers want to use iSCSI multipath, and the connector has the 'multipath=True' value, then drivers should change to return 'target_portals', 'target_iqns' and 'target_luns'.

Existing drivers that support target_portal discovery via the existing process won't need to change unless they want to honor the 'multipath=True' connector entry when exporting a volume.

Existing drivers which support multipath with the existing design must work even if they don't support this change. Such drivers will return single 'target_portal'/'target_iqn'/'target_lun' even if 'multipath=True' is specified. Then the connector must send discovery query to the returned portal in order to find the multipath portals and targets, like the existing design.

Implementation

Assignee(s)

Primary assignee:

tsekiyama

Work Items

  • Implement this feature in LVM iSCSI driver as a sample
  • Enable nova and brick library to handle multiple portals/iqns/luns.

Dependencies

None

Testing

  • Unit tests should be added for drivers which support this feature, so that initialize_connection will return correct connection_info.
  • To test this feature in tempest, multiple addresses must be asigned to the test environment in order to establish multiple sessions to volumes. Implementation in LVM iSCSI driver would be useful for testing.

Documentation Impact

A section to describe this feature should be added.

If the driver needs additional settings for this feature, the documentation for them should be added.

References