Efficient volume copy for volume migration
|
|
==========================================
|
|
|
|
https://blueprints.launchpad.net/cinder/+spec/efficient-volume-copy-for-cinder-assisted-migration
|
|
|
|
Currently, cinder supports these 3 ways for volume migration.
|
|
|
|
+-+--------------------+---------------------------+----------------------+
|
|
|#| Migration method | Data copy method | Handler of migration |
|
|
+=+====================+===========================+======================+
|
|
|1| storage driver | depend on vendor storage | inside storage array |
|
|
+-+--------------------+---------------------------+----------------------+
|
|
|2| copy_volume_data() | dd command | cinder volume node |
|
|
+-+--------------------+---------------------------+----------------------+
|
|
|3| swap_volume() | libvirt block rebase copy | nova compute node |
|
|
+-+--------------------+---------------------------+----------------------+
|
|
|
|
During volume migration case #2, Cinder uses dd command for data copy
|
|
of volume migration, but the copy always copies full blocks even if
|
|
the source data contains many null and zero blocks.
|
|
The dd command has an option conv=sparse to skip null or zero blocks for
|
|
more efficient data copy.
|
|
|
|
The purpose of this request is to introduce a mechanism to handle sparse
|
|
copy option properly for volume migration using dd command.
|
|
|
|
Problem description
|
|
===================
|
|
|
|
If we create a volume from thin-provisioning pool, volume blocks are
|
|
not pre-allocated, and the volume blocks will be allocated on demand.
|
|
In this situation, if we migrate detached volume using dd command,
|
|
dd will copy full block from source to destination volume even if
|
|
the source volume contains many null or zero blocks. As a result,
|
|
usage of the destination volume will be always 100%. Here is an example
|
|
volume migration using thin LVM driver.
|
|
|
|
* Before migration
|
|
|
|
::
|
|
|
|
LV VG Attr LSize Pool Origin Data%
|
|
vg1-pool vg1 twi-a-tz-- 3.80g 10.28
|
|
volume-1234 vg1 Vwi-a-tz-- 1.00g vg1-pool 19.53
|
|
|
|
* After migration without conv=sparse option
|
|
|
|
::
|
|
|
|
LV VG Attr LSize Pool Origin Data%
|
|
vg2-pool vg2 twi-a-tz-- 3.80g 31.45
|
|
volume-1234 vg2 Vwi-a-tz-- 1.00g vg2-pool 100.00
|
|
|
|
Use Cases
|
|
=========
|
|
|
|
Using sparse copy is able to reduce volume usage of destination storage
|
|
array compared to using full block copy.
|
|
|
|
Proposed change
|
|
===============
|
|
|
|
If the volume pre-initilization(zero cleared) is ensured beforehand
|
|
at the destination c-vol, we can skip copy of null and zero blocks
|
|
to destination volume by using conv=sparse option for dd.
|
|
|
|
However, if the destination volume is not zero cleared beforehand,
|
|
we should disable sparse copy and copy full block from source to
|
|
destination volume to avoid data corruption problem.
|
|
|
|
For example, following case, we should disable sparse copy and copy
|
|
full block because new volume of thick LVM might not be initialized,
|
|
we must not use conv=sparse option for similar cases.
|
|
|
|
* Source c-vol driver: Thin LVM
|
|
* Dest c-vol driver: Drivers who provides an uninitialized new volume.
|
|
(ex. Thick LVM)
|
|
|
|
In order to handle sparse option properly, following changes
|
|
are required.
|
|
|
|
1. Add cinder_sparse_copy_volume capability into capabilities list
|
|
as a well-defined option.
|
|
|
|
::
|
|
|
|
'cinder_sparse_copy_volume': {
|
|
'default': 'False',
|
|
options: {}
|
|
},
|
|
|
|
2. Get capability list from the "destination cinder volume driver"
|
|
using ``get_capabilities`` method before starting volume copy.
|
|
|
|
``get_capabilities`` method is proposed following Spec.
|
|
|
|
* Updating Get Volume Driver Capabilities Spec:
|
|
https://review.openstack.org/#/c/183947/1
|
|
|
|
These are steps of migrate_volume related to sparse copy.
|
|
|
|
::
|
|
|
|
source c-vol driver dest c-vol driver
|
|
| |
|
|
| ========================================> |
|
|
| Ask capability of sparse copy via |
|
|
| get_capabilities |
|
|
| <======================================== |
|
|
| Dest c-vol returns capabilities to |
|
|
| source c-vol |
|
|
| ========================================> |
|
|
| Start volume copy with or without sparse |
|
|
| based on the retun from dest c-vol |
|
|
| |
|
|
|
|
|
|
Alternatives
|
|
------------
|
|
|
|
Copy full blocks from source volume to destination volume. And then,
|
|
try fstrim or blkdiscard to release unused blocks to backend storage.
|
|
However, if the backend storage doesn't support UNMAP SCSI command,
|
|
we can't release unused blocks after migration.
|
|
|
|
Data model impact
|
|
-----------------
|
|
|
|
None
|
|
|
|
REST API impact
|
|
---------------
|
|
|
|
Add cinder_sparse_copy_volume parameter as a well_defined capability.
|
|
|
|
::
|
|
|
|
'cinder_sparse_copy_volume': {
|
|
'default': 'False',
|
|
options: {}
|
|
},
|
|
|
|
Security impact
|
|
---------------
|
|
|
|
None
|
|
|
|
Notifications impact
|
|
--------------------
|
|
|
|
None
|
|
|
|
Other end user impact
|
|
---------------------
|
|
|
|
None
|
|
|
|
Performance Impact
|
|
------------------
|
|
|
|
* This feature improves required time to copy data between source and
|
|
destination volume.
|
|
|
|
Other deployer impact
|
|
---------------------
|
|
|
|
None
|
|
|
|
Developer impact
|
|
----------------
|
|
|
|
None
|
|
|
|
Implementation
|
|
==============
|
|
|
|
Assignee(s)
|
|
-----------
|
|
|
|
Primary assignee:
|
|
mitsuhiro-tanino
|
|
|
|
Work Items
|
|
----------
|
|
|
|
* Add cinder_sparse_copy_volume capability into capabilities list.
|
|
* Add handler of get_capabilities in migrate_volume method.
|
|
* Update LVM reference implementation with cinder_sparse_copy_volume
|
|
capability.
|
|
* Update NFS driver with cinder_sparse_copy_volume capability:
|
|
|
|
NFS driver already has _sparse_copy_volume_data option but this way
|
|
doesn't ask capability to destination cinder volume before volume copy.
|
|
We should use same way to handle sparse copy.
|
|
|
|
|
|
Dependencies
|
|
============
|
|
|
|
None
|
|
|
|
Testing
|
|
=======
|
|
|
|
* Unit tests
|
|
|
|
Documentation Impact
|
|
====================
|
|
|
|
* Need to update openstack cloud administrator guide.
|
|
http://docs.openstack.org/admin-guide/blockstorage_volume_migration.html
|
|
|
|
References
|
|
==========
|
|
|
|
* Related Cinder Spec
|
|
|
|
Updating Get Volume Driver Capabilities Spec:
|
|
https://review.openstack.org/#/c/183947/1
|
|
|
|
* Related fix
|
|
|
|
https://review.openstack.org/#/c/183633/
|