Update known issue for iDRAC Swift firmware update
The issue is fixed in iDRAC firmware 6.00.00.00. Change-Id: Ie5b9ce3ed2a9b1cd61d51f64d72403f7dbc5367b
This commit is contained in:
parent
565e3c4bff
commit
70812aa6ed
@ -934,13 +934,14 @@ selected if default plug-in type has been used and never changed. Systems that
|
||||
have plug-in type changed will keep selected plug-in type after iDRAC firmware
|
||||
upgrade.
|
||||
|
||||
Firmware update from Swift fails
|
||||
--------------------------------
|
||||
Firmware update from Swift fails before 6.00.00.00
|
||||
--------------------------------------------------
|
||||
|
||||
When using Swift to stage firmware update files in Management interface
|
||||
``firmware_update`` clean step of ``redfish`` or ``idrac`` hardware type, the
|
||||
cleaning fails with error "An internal error occurred. Unable to complete the
|
||||
specified operation." in iDRAC job. Until this is fixed, use HTTP service to
|
||||
stage firmware files for iDRAC.
|
||||
With iDRAC firmware prior to 6.00.00.00 and when using Swift to stage firmware
|
||||
update files in Management interface ``firmware_update`` clean step of
|
||||
``redfish`` or ``idrac`` hardware type, the cleaning fails with error
|
||||
"An internal error occurred. Unable to complete the specified operation." in
|
||||
iDRAC job. This is fixed in iDRAC firmware 6.00.00.00. If cannot upgrade, then
|
||||
use HTTP service to stage firmware files for iDRAC.
|
||||
|
||||
.. _SCP_Reference_Guide: http://downloads.dell.com/manuals/common/dellemc-server-config-profile-refguide.pdf
|
||||
|
@ -0,0 +1,8 @@
|
||||
---
|
||||
other:
|
||||
- |
|
||||
Known issue when using iDRAC with Swift to stage firmware update files in
|
||||
Management interface ``firmware_update`` clean step of ``redfish`` or
|
||||
``idrac`` hardware type has been fixed in iDRAC firmware 6.00.00.00.
|
||||
Upgrade when possible or use HTTP service to stage firmware files for
|
||||
iDRAC.
|
Loading…