Update known issue for iDRAC Swift firmware update

The issue is fixed in iDRAC firmware 6.00.00.00.

Change-Id: Ie5b9ce3ed2a9b1cd61d51f64d72403f7dbc5367b
This commit is contained in:
Aija Jauntēva 2022-07-12 06:39:16 -04:00
parent 565e3c4bff
commit 70812aa6ed
2 changed files with 16 additions and 7 deletions

View File

@ -934,13 +934,14 @@ selected if default plug-in type has been used and never changed. Systems that
have plug-in type changed will keep selected plug-in type after iDRAC firmware
upgrade.
Firmware update from Swift fails
--------------------------------
Firmware update from Swift fails before 6.00.00.00
--------------------------------------------------
When using Swift to stage firmware update files in Management interface
``firmware_update`` clean step of ``redfish`` or ``idrac`` hardware type, the
cleaning fails with error "An internal error occurred. Unable to complete the
specified operation." in iDRAC job. Until this is fixed, use HTTP service to
stage firmware files for iDRAC.
With iDRAC firmware prior to 6.00.00.00 and when using Swift to stage firmware
update files in Management interface ``firmware_update`` clean step of
``redfish`` or ``idrac`` hardware type, the cleaning fails with error
"An internal error occurred. Unable to complete the specified operation." in
iDRAC job. This is fixed in iDRAC firmware 6.00.00.00. If cannot upgrade, then
use HTTP service to stage firmware files for iDRAC.
.. _SCP_Reference_Guide: http://downloads.dell.com/manuals/common/dellemc-server-config-profile-refguide.pdf

View File

@ -0,0 +1,8 @@
---
other:
- |
Known issue when using iDRAC with Swift to stage firmware update files in
Management interface ``firmware_update`` clean step of ``redfish`` or
``idrac`` hardware type has been fixed in iDRAC firmware 6.00.00.00.
Upgrade when possible or use HTTP service to stage firmware files for
iDRAC.