Updates ironic documentation to change "openstack baremetal" to "baremetal" Change-Id: I95afa010aeb4fb08aff05adf0cfb7a200db8a53f Story: #2008194 Task: #40962
10 KiB
Multi-tenancy in the Bare Metal service
Overview
It is possible to use dedicated tenant networks for provisioned nodes, which extends the current Bare Metal service capabilities of providing flat networks. This works in conjunction with the Networking service to allow provisioning of nodes in a separate provisioning network. The result of this is that multiple tenants can use nodes in an isolated fashion. However, this configuration does not support trunk ports belonging to multiple networks.
Concepts
Network interfaces
Network interface is one of the driver interfaces that manages network switching for nodes. There are 3 network interfaces available in the Bare Metal service:
noop
interface is used for standalone deployments, and does not perform any network switching;flat
interface places all nodes into a single provider network that is pre-configured on the Networking service and physical equipment. Nodes remain physically connected to this network during their entire life cycle.neutron
interface provides tenant-defined networking through the Networking service, separating tenant networks from each other and from the provisioning and cleaning provider networks. Nodes will move between these networks during their life cycle. This interface requires Networking service support for the switches attached to the baremetal servers so they can be programmed.
Local link connection
The Bare Metal service allows local_link_connection
information to be associated with Bare Metal ports. This information is
provided to the Networking service's ML2 driver when a Virtual Interface
(VIF) is attached. The ML2 driver uses the information to plug the
specified port to the tenant network.
Field | Description |
---|---|
switch_id |
Required. Identifies a switch and can be a MAC address or an
OpenFlow-based datapath_id . |
port_id |
Required. Port ID on the switch/Smart NIC, for example, Gig0/1, rep0-0. |
switch_info |
Optional. Used to distinguish different switch models or other vendor-specific identifier. Some ML2 plugins may require this field. |
hostname |
Required in case of a Smart NIC port. Hostname of Smart NIC device. |
Note
This isn't applicable to Infiniband ports because the network topology is discoverable by the Infiniband Subnet Manager. If specified, local_link_connection information will be ignored. If port is Smart NIC port then:
port_id
is the representor port name on the Smart NIC.switch_id
is not mandatory.
Physical networks
A Bare Metal port may be associated with a physical network using its
physical_network
field. The Bare Metal service uses this
information when mapping between virtual ports in the Networking service
and physical ports and port groups in the Bare Metal service. A port's
physical network field is optional, and if not set then any virtual port
may be mapped to that port, provided that no free Bare Metal port with a
suitable physical network assignment exists.
The physical network of a port group is defined by the physical network of its constituent ports. The Bare Metal service ensures that all ports in a port group have the same value in their physical network field.
When attaching a virtual interface (VIF) to a node, the following ordered criteria are used to select a suitable unattached port or port group:
- Require ports or port groups to not have a physical network or to have a physical network that matches one of the VIF's allowed physical networks.
- Prefer ports and port groups that have a physical network to ports and port groups that do not have a physical network.
- Prefer port groups to ports. Prefer ports with PXE enabled.
Configuring the Bare Metal service
See the configure-tenant-networks
section in the installation
guide for the Bare Metal service.
Configuring nodes
Ensure that your python-ironicclient version and requested API version are sufficient for your requirements.
- Multi-tenancy support was added in API version 1.20, and is supported by python-ironicclient version 1.5.0 or higher.
- Physical network support for ironic ports was added in API version 1.34, and is supported by python-ironicclient version 1.15.0 or higher.
- Smart NIC support for ironic ports was added in API version 1.53, and is supported by python-ironicclient version 2.7.0 or higher.
The following examples assume you are using python-ironicclient version 2.7.0 or higher.
Export the following variable:
export OS_BAREMETAL_API_VERSION=<API version>
The node's
network_interface
field should be set to a valid network interface. Valid interfaces are listed in the[DEFAULT]/enabled_network_interfaces
configuration option in the ironic-conductor's configuration file. Set it toneutron
to use the Networking service's ML2 driver:baremetal node create --network-interface neutron --driver ipmi
Note
If the
[DEFAULT]/default_network_interface
configuration option is set, the--network-interface
option does not need to be specified when creating the node.To update an existing node's network interface to
neutron
, use the following commands:baremetal node set $NODE_UUID_OR_NAME \ --network-interface neutron
Create a port as follows:
baremetal port create $HW_MAC_ADDRESS --node $NODE_UUID \ --local-link-connection switch_id=$SWITCH_MAC_ADDRESS \ --local-link-connection switch_info=$SWITCH_HOSTNAME \ --local-link-connection port_id=$SWITCH_PORT \ --pxe-enabled true \ --physical-network physnet1
An Infiniband port requires client ID, while local link connection information will be populated by Infiniband Subnet Manager. The client ID consists of <12-byte vendor prefix>:<8 byte port GUID>. There is no standard process for deriving the port's MAC address ($HW_MAC_ADDRESS); it is vendor specific. For example, Mellanox ConnectX Family Devices prefix is ff:00:00:00:00:00:02:00:00:02:c9:00. If port GUID was f4:52:14:03:00:38:39:81 the client ID would be ff:00:00:00:00:00:02:00:00:02:c9:00:f4:52:14:03:00:38:39:81. Mellanox ConnectX Family Device's HW_MAC_ADDRESS consists of 6 bytes; the port GUID's lower 3 and higher 3 bytes. In this example it would be f4:52:14:38:39:81. Putting it all together, create an Infiniband port as follows:
baremetal port create $HW_MAC_ADDRESS --node $NODE_UUID \ --pxe-enabled true \ --extra client-id=$CLIENT_ID \ --physical-network physnet1
Create a Smart NIC port as follows:
baremetal port create $HW_MAC_ADDRESS --node $NODE_UUID \ --local-link-connection hostname=$HOSTNAME \ --local-link-connection port_id=$REP_NAME \ --pxe-enabled true \ --physical-network physnet1 \ --is-smartnic
A Smart NIC port requires
hostname
which is the hostname of the Smart NIC, andport_id
which is the representor port name within the Smart NIC.Check the port configuration:
baremetal port show $PORT_UUID
After these steps, the provisioning of the created node will happen in the provisioning network, and then the node will be moved to the tenant network that was requested.
Configuring the Networking service
In addition to configuring the Bare Metal service some additional configuration of the Networking service is required to ensure ports for bare metal servers are correctly programmed. This configuration will be determined by the Bare Metal service network interfaces you have enabled and which top of rack switches you have in your environment.
flat
network interface
In order for Networking service ports to correctly operate with the
Bare Metal service flat
network interface the
baremetal
ML2 mechanism driver from networking-baremetal
needs to be loaded into the Networking service configuration. This
driver understands that the switch should be already configured by the
admin, and will mark the networking service ports as successfully bound
as nothing else needs to be done.
Install the
networking-baremetal
library$ pip install networking-baremetal
Enable the
baremetal
driver in the Networking service ML2 configuration file[ml2] mechanism_drivers = ovs,baremetal
neutron
network
interface
The neutron
network interface allows the Networking
service to program the physical top of rack switches for the bare metal
servers. To do this an ML2 mechanism driver which supports the
baremetal
VNIC type for the make and model of top of rack
switch in the environment must be installed and enabled.
This is a list of known top of rack ML2 mechanism drivers which work
with the neutron
network interface:
- Cisco Nexus 9000 series
-
To install and configure this ML2 mechanism driver see Nexus Mechanism Driver Installation Guide.
- FUJITSU CFX2000
-
networking-fujitsu
ML2 driver supports this switch. The documentation is available here. - Networking Generic Switch
-
This is an ML2 mechanism driver built for testing against virtual bare metal environments and some switches that are not covered by hardware specific ML2 mechanism drivers. More information is available in the project's README.