ironic/doc/source/admin/notifications.rst
Dmitry Tantsur 929907d684 Bye-bye iSCSI deploy, you served us well
The iSCSI deploy was very easy to start with, but it has since become
apparently that it suffers from scalability and maintenance issues.
It was deprecated in the Victoria cycle and can now be removed.

Hide the guide to upgrade to hardware types since it's very outdated.

I had to remove the iBMC diagram since my SVG-fu is not enough to fix it.

Change-Id: I2cd6bf7b27fe0be2c08104b0cc37654b506b2e62
2021-05-04 14:28:25 +02:00

833 lines
30 KiB
ReStructuredText

.. _deploy-notifications:
=============
Notifications
=============
Ironic, when configured to do so, will emit notifications over a message bus
that indicate different events that occur within the service. These can be
consumed by any external service. Examples may include a billing or usage
system, a monitoring data store, or other OpenStack services. This page
describes how to enable notifications and the different kinds of notifications
that ironic may emit. The external consumer will see notifications emitted by
ironic as JSON objects structured in the following manner::
{
"priority": <string, defined by the sender>,
"event_type": <string, defined by the sender>,
"timestamp": <string, the isotime of when the notification emitted>,
"publisher_id": <string, defined by the sender>,
"message_id": <uuid, generated by oslo>,
"payload": <json serialized dict, defined by the sender>
}
Configuration
=============
To enable notifications with ironic, there are two configuration options in
ironic.conf that must be adjusted.
The first option is the ``notification_level`` option in the ``[DEFAULT]``
section of the configuration file. This can be set to "debug", "info",
"warning", "error", or "critical", and determines the minimum priority level
for which notifications are emitted. For example, if the option is set to
"warning", all notifications with priority level "warning", "error", or
"critical" are emitted, but not notifications with priority level "debug" or
"info". For information about the semantics of each log level, see the
OpenStack logging standards [1]_. If this option is unset, no notifications
will be emitted. The priority level of each available notification is
documented below.
The second option is the ``transport_url`` option in the
``[oslo_messaging_notifications]`` section of the configuration. This
determines the message bus used when sending notifications. If this is unset,
the default transport used for RPC is used.
All notifications are emitted on the "ironic_versioned_notifications" topic in
the message bus. Generally, each type of message that traverses the message bus
is associated with a topic describing what the message is about. For more
information, see the documentation of your chosen message bus, such as the
RabbitMQ documentation [2]_.
Note that notifications may be lossy, and there's no guarantee that a
notification will make it across the message bus to a consumer.
Versioning
==========
Each notification has an associated version in the "ironic_object.version"
field of the payload. Consumers are guaranteed that microversion bumps will add
new fields, while macroversion bumps are backwards-incompatible and may have
fields removed.
Versioned notifications are emitted by default to the
`ironic_versioned_notifications` topic. This can be changed and it is
configurable in the ironic.conf with the `versioned_notifications_topics`
config option.
Available notifications
=======================
.. TODO(mariojv) Add some form of tabular formatting below
The notifications that ironic emits are described here. They are listed
(alphabetically) by service first, then by event_type. All examples below
show payloads before serialization to JSON.
------------------------
ironic-api notifications
------------------------
Resources CRUD notifications
----------------------------
These notifications are emitted from API service when ironic resources are
modified as part of create, update, or delete (CRUD) [3]_ procedures. All
CRUD notifications are emitted at INFO level, except for "error" status that
is emitted at ERROR level.
List of CRUD notifications for chassis:
* ``baremetal.chassis.create.start``
* ``baremetal.chassis.create.end``
* ``baremetal.chassis.create.error``
* ``baremetal.chassis.update.start``
* ``baremetal.chassis.update.end``
* ``baremetal.chassis.update.error``
* ``baremetal.chassis.delete.start``
* ``baremetal.chassis.delete.end``
* ``baremetal.chassis.delete.error``
Example of chassis CRUD notification::
{
"priority": "info",
"payload":{
"ironic_object.namespace":"ironic",
"ironic_object.name":"ChassisCRUDPayload",
"ironic_object.version":"1.0",
"ironic_object.data":{
"created_at": "2016-04-10T10:13:03+00:00",
"description": "bare 28",
"extra": {},
"updated_at": "2016-04-27T21:11:03+00:00",
"uuid": "1910f669-ce8b-43c2-b1d8-cf3d65be815e"
}
},
"event_type":"baremetal.chassis.update.end",
"publisher_id":"ironic-api.hostname02"
}
List of CRUD notifications for deploy template:
* ``baremetal.deploy_template.create.start``
* ``baremetal.deploy_template.create.end``
* ``baremetal.deploy_template.create.error``
* ``baremetal.deploy_template.update.start``
* ``baremetal.deploy_template.update.end``
* ``baremetal.deploy_template.update.error``
* ``baremetal.deploy_template.delete.start``
* ``baremetal.deploy_template.delete.end``
* ``baremetal.deploy_template.delete.error``
Example of deploy template CRUD notification::
{
"priority": "info",
"payload":{
"ironic_object.namespace":"ironic",
"ironic_object.name":"DeployTemplateCRUDPayload",
"ironic_object.version":"1.0",
"ironic_object.data":{
"created_at": "2019-02-10T10:13:03+00:00",
"extra": {},
"name": "CUSTOM_HYPERTHREADING_ON",
"steps": [
{
"interface": "bios",
"step": "apply_configuration",
"args": {
"settings": [
{
"name": "LogicalProc",
"value": "Enabled"
}
]
},
"priority": 150
}
],
"updated_at": "2019-02-27T21:11:03+00:00",
"uuid": "1910f669-ce8b-43c2-b1d8-cf3d65be815e"
}
},
"event_type":"baremetal.deploy_template.update.end",
"publisher_id":"ironic-api.hostname02"
}
List of CRUD notifications for node:
* ``baremetal.node.create.start``
* ``baremetal.node.create.end``
* ``baremetal.node.create.error``
* ``baremetal.node.update.start``
* ``baremetal.node.update.end``
* ``baremetal.node.update.error``
* ``baremetal.node.delete.start``
* ``baremetal.node.delete.end``
* ``baremetal.node.delete.error``
Example of node CRUD notification::
{
"priority": "info",
"payload":{
"ironic_object.namespace":"ironic",
"ironic_object.name":"NodeCRUDPayload",
"ironic_object.version":"1.13",
"ironic_object.data":{
"chassis_uuid": "db0eef9d-45b2-4dc0-94a8-fc283c01171f",
"clean_step": None,
"conductor_group": "",
"console_enabled": False,
"created_at": "2016-01-26T20:41:03+00:00",
"deploy_step": None,
"description": "my sample node",
"driver": "ipmi",
"driver_info": {
"ipmi_address": "192.168.0.111",
"ipmi_username": "root"},
"extra": {},
"inspection_finished_at": None,
"inspection_started_at": None,
"instance_info": {},
"instance_uuid": None,
"last_error": None,
"lessee": None,
"maintenance": False,
"maintenance_reason": None,
"fault": None,
"bios_interface": "no-bios",
"boot_interface": "pxe",
"console_interface": "no-console",
"deploy_interface": "direct",
"inspect_interface": "no-inspect",
"management_interface": "ipmitool",
"network_interface": "flat",
"power_interface": "ipmitool",
"raid_interface": "no-raid",
"rescue_interface": "no-rescue",
"storage_interface": "noop",
"vendor_interface": "no-vendor",
"name": None,
"owner": None,
"power_state": "power off",
"properties": {
"memory_mb": 4096,
"cpu_arch": "x86_64",
"local_gb": 10,
"cpus": 8},
"protected": False,
"protected_reason": None,
"provision_state": "deploying",
"provision_updated_at": "2016-01-27T20:41:03+00:00",
"resource_class": None,
"retired": None,
"retired_reason": None,
"target_power_state": None,
"target_provision_state": "active",
"traits": [
"CUSTOM_TRAIT1",
"HW_CPU_X86_VMX"],
"updated_at": "2016-01-27T20:41:03+00:00",
"uuid": "1be26c0b-03f2-4d2e-ae87-c02d7f33c123"
}
},
"event_type":"baremetal.node.update.end",
"publisher_id":"ironic-api.hostname02"
}
List of CRUD notifications for port:
* ``baremetal.port.create.start``
* ``baremetal.port.create.end``
* ``baremetal.port.create.error``
* ``baremetal.port.update.start``
* ``baremetal.port.update.end``
* ``baremetal.port.update.error``
* ``baremetal.port.delete.start``
* ``baremetal.port.delete.end``
* ``baremetal.port.delete.error``
Example of port CRUD notification::
{
"priority": "info",
"payload":{
"ironic_object.namespace":"ironic",
"ironic_object.name":"PortCRUDPayload",
"ironic_object.version":"1.3",
"ironic_object.data":{
"address": "77:66:23:34:11:b7",
"created_at": "2016-02-11T15:23:03+00:00",
"node_uuid": "5b236cab-ad4e-4220-b57c-e827e858745a",
"extra": {},
"is_smartnic": True,
"local_link_connection": {},
"physical_network": "physnet1",
"portgroup_uuid": "bd2f385e-c51c-4752-82d1-7a9ec2c25f24",
"pxe_enabled": True,
"updated_at": "2016-03-27T20:41:03+00:00",
"uuid": "1be26c0b-03f2-4d2e-ae87-c02d7f33c123"
}
},
"event_type":"baremetal.port.update.end",
"publisher_id":"ironic-api.hostname02"
}
List of CRUD notifications for port group:
* ``baremetal.portgroup.create.start``
* ``baremetal.portgroup.create.end``
* ``baremetal.portgroup.create.error``
* ``baremetal.portgroup.update.start``
* ``baremetal.portgroup.update.end``
* ``baremetal.portgroup.update.error``
* ``baremetal.portgroup.delete.start``
* ``baremetal.portgroup.delete.end``
* ``baremetal.portgroup.delete.error``
Example of portgroup CRUD notification::
{
"priority": "info",
"payload":{
"ironic_object.namespace":"ironic",
"ironic_object.name":"PortgroupCRUDPayload",
"ironic_object.version":"1.0",
"ironic_object.data":{
"address": "11:44:32:87:61:e5",
"created_at": "2017-01-11T11:33:03+00:00",
"node_uuid": "5b236cab-ad4e-4220-b57c-e827e858745a",
"extra": {},
"mode": "7",
"name": "portgroup-node-18",
"properties": {},
"standalone_ports_supported": True,
"updated_at": "2017-01-31T11:41:07+00:00",
"uuid": "db033a40-bfed-4c84-815a-3db26bb268bb",
}
},
"event_type":"baremetal.portgroup.update.end",
"publisher_id":"ironic-api.hostname02"
}
List of CRUD notifications for volume connector:
* ``baremetal.volumeconnector.create.start``
* ``baremetal.volumeconnector.create.end``
* ``baremetal.volumeconnector.create.error``
* ``baremetal.volumeconnector.update.start``
* ``baremetal.volumeconnector.update.end``
* ``baremetal.volumeconnector.update.error``
* ``baremetal.volumeconnector.delete.start``
* ``baremetal.volumeconnector.delete.end``
* ``baremetal.volumeconnector.delete.error``
Example of volume connector CRUD notification::
{
"priority": "info",
"payload": {
"ironic_object.namespace": "ironic",
"ironic_object.name": "VolumeConnectorCRUDPayload",
"ironic_object.version": "1.0",
"ironic_object.data": {
"connector_id": "iqn.2017-05.org.openstack:01:d9a51732c3f",
"created_at": "2017-05-11T05:57:36+00:00",
"extra": {},
"node_uuid": "4dbb4e69-99a8-4e13-b6e8-dd2ad4a20caf",
"type": "iqn",
"updated_at": "2017-05-11T08:28:58+00:00",
"uuid": "19b9f3ab-4754-4725-a7a4-c43ea7e57360"
}
},
"event_type": "baremetal.volumeconnector.update.end",
"publisher_id":"ironic-api.hostname02"
}
List of CRUD notifications for volume target:
* ``baremetal.volumetarget.create.start``
* ``baremetal.volumetarget.create.end``
* ``baremetal.volumetarget.create.error``
* ``baremetal.volumetarget.update.start``
* ``baremetal.volumetarget.update.end``
* ``baremetal.volumetarget.update.error``
* ``baremetal.volumetarget.delete.start``
* ``baremetal.volumetarget.delete.end``
* ``baremetal.volumetarget.delete.error``
Example of volume target CRUD notification::
{
"priority": "info",
"payload": {
"ironic_object.namespace": "ironic",
"ironic_object.version": "1.0",
"ironic_object.name": "VolumeTargetCRUDPayload"
"ironic_object.data": {
"boot_index": 0,
"created_at": "2017-05-11T09:38:59+00:00",
"extra": {},
"node_uuid": "4dbb4e69-99a8-4e13-b6e8-dd2ad4a20caf",
"properties": {
"access_mode": "rw",
"auth_method": "CHAP"
"auth_password": "***",
"auth_username": "urxhQCzAKr4sjyE8DivY",
"encrypted": false,
"qos_specs": null,
"target_discovered": false,
"target_iqn": "iqn.2010-10.org.openstack:volume-f0d9b0e6-b242-9105-91d4-a20331693ad8",
"target_lun": 1,
"target_portal": "192.168.12.34:3260",
"volume_id": "f0d9b0e6-b042-4105-91d4-a20331693ad8",
},
"updated_at": "2017-05-11T09:52:04+00:00",
"uuid": "82a45833-9c58-4ec1-943c-2091ab10e47b",
"volume_id": "f0d9b0e6-b242-9105-91d4-a20331693ad8",
"volume_type": "iscsi"
}
},
"event_type": "baremetal.volumetarget.update.end",
"publisher_id":"ironic-api.hostname02"
}
Node maintenance notifications
------------------------------
These notifications are emitted from API service when maintenance mode is
changed via API service. List of maintenance notifications for a node:
* ``baremetal.node.maintenance_set.start``
* ``baremetal.node.maintenance_set.end``
* ``baremetal.node.maintenance_set.error``
"start" and "end" notifications have INFO level, "error" has ERROR. Example of
node maintenance notification::
{
"priority": "info",
"payload":{
"ironic_object.namespace":"ironic",
"ironic_object.name":"NodePayload",
"ironic_object.version":"1.15",
"ironic_object.data":{
"clean_step": None,
"conductor_group": "",
"console_enabled": False,
"created_at": "2016-01-26T20:41:03+00:00",
"deploy_step": None,
"description": "my sample node",
"driver": "ipmi",
"extra": {},
"inspection_finished_at": None,
"inspection_started_at": None,
"instance_info": {},
"instance_uuid": None,
"last_error": None,
"lessee": None,
"maintenance": True,
"maintenance_reason": "hw upgrade",
"fault": None,
"bios_interface": "no-bios",
"boot_interface": "pxe",
"console_interface": "no-console",
"deploy_interface": "direct",
"inspect_interface": "no-inspect",
"management_interface": "ipmitool",
"network_interface": "flat",
"power_interface": "ipmitool",
"raid_interface": "no-raid",
"rescue_interface": "no-rescue",
"storage_interface": "noop",
"vendor_interface": "no-vendor",
"name": None,
"owner": None,
"power_state": "power off",
"properties": {
"memory_mb": 4096,
"cpu_arch": "x86_64",
"local_gb": 10,
"cpus": 8},
"protected": False,
"protected_reason": None,
"provision_state": "available",
"provision_updated_at": "2016-01-27T20:41:03+00:00",
"resource_class": None,
"retired": None,
"retired_reason": None,
"target_power_state": None,
"target_provision_state": None,
"traits": [
"CUSTOM_TRAIT1",
"HW_CPU_X86_VMX"],
"updated_at": "2016-01-27T20:41:03+00:00",
"uuid": "1be26c0b-03f2-4d2e-ae87-c02d7f33c123"
}
},
"event_type":"baremetal.node.maintenance_set.start",
"publisher_id":"ironic-api.hostname02"
}
------------------------------
ironic-conductor notifications
------------------------------
Node console notifications
------------------------------
These notifications are emitted by the ironic-conductor service when conductor
service starts or stops console for the node. The notification event types for
a node console are:
* ``baremetal.node.console_set.start``
* ``baremetal.node.console_set.end``
* ``baremetal.node.console_set.error``
* ``baremetal.node.console_restore.start``
* ``baremetal.node.console_restore.end``
* ``baremetal.node.console_restore.error``
``console_set`` action is used when start or stop console is initiated. The
``console_restore`` action is used when the console was already enabled, but a
driver must restart the console because an ironic-conductor was restarted. This
may also be sent when an ironic-conductor takes over a node that was being
managed by another ironic-conductor. "start" and "end" notifications have INFO
level, "error" has ERROR. Example of node console notification::
{
"priority": "info",
"payload":{
"ironic_object.namespace":"ironic",
"ironic_object.name":"NodePayload",
"ironic_object.version":"1.15",
"ironic_object.data":{
"clean_step": None,
"conductor_group": "",
"console_enabled": True,
"created_at": "2016-01-26T20:41:03+00:00",
"deploy_step": None,
"description": "my sample node",
"driver": "ipmi",
"extra": {},
"inspection_finished_at": None,
"inspection_started_at": None,
"instance_info": {},
"instance_uuid": None,
"last_error": None,
"lessee": None,
"maintenance": False,
"maintenance_reason": None,
"fault": None,
"bios_interface": "no-bios",
"boot_interface": "pxe",
"console_interface": "no-console",
"deploy_interface": "direct",
"inspect_interface": "no-inspect",
"management_interface": "ipmitool",
"network_interface": "flat",
"power_interface": "ipmitool",
"raid_interface": "no-raid",
"rescue_interface": "no-rescue",
"storage_interface": "noop",
"vendor_interface": "no-vendor",
"name": None,
"owner": None,
"power_state": "power off",
"properties": {
"memory_mb": 4096,
"cpu_arch": "x86_64",
"local_gb": 10,
"cpus": 8},
"protected": False,
"protected_reason": None,
"provision_state": "available",
"provision_updated_at": "2016-01-27T20:41:03+00:00",
"resource_class": None,
"retired": None,
"retired_reason": None,
"target_power_state": None,
"target_provision_state": None,
"traits": [
"CUSTOM_TRAIT1",
"HW_CPU_X86_VMX"],
"updated_at": "2016-01-27T20:41:03+00:00",
"uuid": "1be26c0b-03f2-4d2e-ae87-c02d7f33c123"
}
},
"event_type":"baremetal.node.console_set.end",
"publisher_id":"ironic-conductor.hostname01"
}
baremetal.node.power_set
------------------------
* ``baremetal.node.power_set.start`` is emitted by the ironic-conductor service
when it begins a power state change. It has notification level "info".
* ``baremetal.node.power_set.end`` is emitted when ironic-conductor
successfully completes a power state change task. It has notification level
"info".
* ``baremetal.node.power_set.error`` is emitted by ironic-conductor when it
fails to set a node's power state. It has notification level "error". This
can occur when ironic fails to retrieve the old power state prior to setting
the new one on the node, or when it fails to set the power state if a change
is requested.
Here is an example payload for a notification with this event type. The
"to_power" payload field indicates the power state to which the
ironic-conductor is attempting to change the node::
{
"priority": "info",
"payload":{
"ironic_object.namespace":"ironic",
"ironic_object.name":"NodeSetPowerStatePayload",
"ironic_object.version":"1.15",
"ironic_object.data":{
"clean_step": None,
"conductor_group": "",
"console_enabled": False,
"created_at": "2016-01-26T20:41:03+00:00",
"deploy_step": None,
"description": "my sample node",
"driver": "ipmi",
"extra": {},
"inspection_finished_at": None,
"inspection_started_at": None,
"instance_uuid": "d6ea00c1-1f94-4e95-90b3-3462d7031678",
"last_error": None,
"lessee": None,
"maintenance": False,
"maintenance_reason": None,
"fault": None,
"bios_interface": "no-bios",
"boot_interface": "pxe",
"console_interface": "no-console",
"deploy_interface": "direct",
"inspect_interface": "no-inspect",
"management_interface": "ipmitool",
"network_interface": "flat",
"power_interface": "ipmitool",
"raid_interface": "no-raid",
"rescue_interface": "no-rescue",
"storage_interface": "noop",
"vendor_interface": "no-vendor",
"name": None,
"owner": None,
"power_state": "power off",
"properties": {
"memory_mb": 4096,
"cpu_arch": "x86_64",
"local_gb": 10,
"cpus": 8},
"protected": False,
"protected_reason": None
"provision_state": "available",
"provision_updated_at": "2016-01-27T20:41:03+00:00",
"resource_class": None,
"retired": None,
"retired_reason": None,
"target_power_state": None,
"target_provision_state": None,
"traits": [
"CUSTOM_TRAIT1",
"HW_CPU_X86_VMX"],
"updated_at": "2016-01-27T20:41:03+00:00",
"uuid": "1be26c0b-03f2-4d2e-ae87-c02d7f33c123",
"to_power": "power on"
}
},
"event_type":"baremetal.node.power_set.start",
"publisher_id":"ironic-conductor.hostname01"
}
baremetal.node.power_state_corrected
------------------------------------
* ``baremetal.node.power_state_corrected.success`` is emitted by
ironic-conductor when the power state on the baremetal hardware is different
from the previous known power state of the node and the database is corrected
to reflect this new power state. It has notification level "info".
Here is an example payload for a notification with this event_type. The
"from_power" payload field indicates the previous power state on the node,
prior to the correction::
{
"priority": "info",
"payload":{
"ironic_object.namespace":"ironic",
"ironic_object.name":"NodeCorrectedPowerStatePayload",
"ironic_object.version":"1.15",
"ironic_object.data":{
"clean_step": None,
"conductor_group": "",
"console_enabled": False,
"created_at": "2016-01-26T20:41:03+00:00",
"deploy_step": None,
"description": "my sample node",
"driver": "ipmi",
"extra": {},
"inspection_finished_at": None,
"inspection_started_at": None,
"instance_uuid": "d6ea00c1-1f94-4e95-90b3-3462d7031678",
"last_error": None,
"lessee": None,
"maintenance": False,
"maintenance_reason": None,
"fault": None,
"bios_interface": "no-bios",
"boot_interface": "pxe",
"console_interface": "no-console",
"deploy_interface": "direct",
"inspect_interface": "no-inspect",
"management_interface": "ipmitool",
"network_interface": "flat",
"power_interface": "ipmitool",
"raid_interface": "no-raid",
"rescue_interface": "no-rescue",
"storage_interface": "noop",
"vendor_interface": "no-vendor",
"name": None,
"owner": None,
"power_state": "power off",
"properties": {
"memory_mb": 4096,
"cpu_arch": "x86_64",
"local_gb": 10,
"cpus": 8},
"protected": False,
"protected_reason": None,
"provision_state": "available",
"provision_updated_at": "2016-01-27T20:41:03+00:00",
"resource_class": None,
"retired": None,
"retired_reason": None,
"target_power_state": None,
"target_provision_state": None,
"traits": [
"CUSTOM_TRAIT1",
"HW_CPU_X86_VMX"],
"updated_at": "2016-01-27T20:41:03+00:00",
"uuid": "1be26c0b-03f2-4d2e-ae87-c02d7f33c123",
"from_power": "power on"
}
},
"event_type":"baremetal.node.power_state_corrected.success",
"publisher_id":"ironic-conductor.cond-hostname02"
}
baremetal.node.provision_set
----------------------------
* ``baremetal.node.provision_set.start`` is emitted by the ironic-conductor
service when it begins a provision state transition. It has notification
level INFO.
* ``baremetal.node.provision_set.end`` is emitted when ironic-conductor
successfully completes a provision state transition. It has notification
level INFO.
* ``baremetal.node.provision_set.success`` is emitted when ironic-conductor
successfully changes provision state instantly, without any intermediate
work required (example is AVAILABLE to MANAGEABLE). It has notification level
INFO.
* ``baremetal.node.provision_set.error`` is emitted by ironic-conductor when it
changes provision state as result of error event processing. It has
notification level ERROR.
Here is an example payload for a notification with this event type. The
"previous_provision_state" and "previous_target_provision_state" payload fields
indicate a node's provision states before state change, "event" is the FSM
(finite state machine) event that triggered the state change::
{
"priority": "info",
"payload":{
"ironic_object.namespace":"ironic",
"ironic_object.name":"NodeSetProvisionStatePayload",
"ironic_object.version":"1.16",
"ironic_object.data":{
"clean_step": None,
"conductor_group": "",
"console_enabled": False,
"created_at": "2016-01-26T20:41:03+00:00",
"deploy_step": None,
"description": "my sample node",
"driver": "ipmi",
"driver_internal_info": {
"is_whole_disk_image": True},
"extra": {},
"inspection_finished_at": None,
"inspection_started_at": None,
"instance_info": {},
"instance_uuid": None,
"last_error": None,
"lessee": None,
"maintenance": False,
"maintenance_reason": None,
"fault": None,
"bios_interface": "no-bios",
"boot_interface": "pxe",
"console_interface": "no-console",
"deploy_interface": "direct",
"inspect_interface": "no-inspect",
"management_interface": "ipmitool",
"network_interface": "flat",
"power_interface": "ipmitool",
"raid_interface": "no-raid",
"rescue_interface": "no-rescue",
"storage_interface": "noop",
"vendor_interface": "no-vendor",
"name": None,
"owner": None,
"power_state": "power off",
"properties": {
"memory_mb": 4096,
"cpu_arch": "x86_64",
"local_gb": 10,
"cpus": 8},
"protected": False,
"protected_reason": None,
"provision_state": "deploying",
"provision_updated_at": "2016-01-27T20:41:03+00:00",
"resource_class": None,
"retired": None,
"retired_reason": None,
"target_power_state": None,
"target_provision_state": "active",
"traits": [
"CUSTOM_TRAIT1",
"HW_CPU_X86_VMX"],
"updated_at": "2016-01-27T20:41:03+00:00",
"uuid": "1be26c0b-03f2-4d2e-ae87-c02d7f33c123",
"previous_provision_state": "available",
"previous_target_provision_state": None,
"event": "deploy"
}
},
"event_type":"baremetal.node.provision_set.start",
"publisher_id":"ironic-conductor.hostname01"
}
.. [1] https://wiki.openstack.org/wiki/LoggingStandards#Log_level_definitions
.. [2] https://www.rabbitmq.com/documentation.html
.. [3] https://en.wikipedia.org/wiki/Create,_read,_update_and_delete