.. _irmc:
|
|
|
|
===========
|
|
iRMC driver
|
|
===========
|
|
|
|
Overview
|
|
========
|
|
|
|
The iRMC driver enables control FUJITSU PRIMERGY via ServerView
|
|
Common Command Interface (SCCI). Support for FUJITSU PRIMERGY servers consists
|
|
of the ``irmc`` hardware type and a few hardware interfaces specific for that
|
|
hardware type.
|
|
|
|
Prerequisites
|
|
=============
|
|
|
|
* Install `python-scciclient <https://pypi.org/project/python-scciclient>`_
|
|
and `pysnmp <https://pypi.org/project/pysnmp>`_ packages::
|
|
|
|
$ pip install "python-scciclient>=0.7.2" pysnmp
|
|
|
|
Hardware Type
|
|
=============
|
|
|
|
The ``irmc`` hardware type is available for FUJITSU PRIMERGY servers. For
|
|
information on how to enable the ``irmc`` hardware type, see
|
|
:ref:`enable-hardware-types`.
|
|
|
|
Hardware interfaces
|
|
^^^^^^^^^^^^^^^^^^^
|
|
|
|
The ``irmc`` hardware type overrides the selection of the following
|
|
hardware interfaces:
|
|
|
|
* bios
|
|
Supports ``irmc`` and ``no-bios``.
|
|
The default is ``irmc``.
|
|
|
|
* boot
|
|
Supports ``irmc-virtual-media``, ``irmc-pxe``, and ``pxe``.
|
|
The default is ``irmc-virtual-media``. The ``irmc-virtual-media`` boot
|
|
interface enables the virtual media based deploy with IPA (Ironic Python
|
|
Agent).
|
|
|
|
.. warning::
|
|
We deprecated the ``pxe`` boot interface when used with ``irmc``
|
|
hardware type. Support for this interface will be removed in the
|
|
future. Instead, use ``irmc-pxe``. ``irmc-pxe`` boot interface
|
|
was introduced in Pike.
|
|
|
|
* console
|
|
Supports ``ipmitool-socat``, ``ipmitool-shellinabox``, and ``no-console``.
|
|
The default is ``ipmitool-socat``.
|
|
|
|
* inspect
|
|
Supports ``irmc``, ``inspector``, and ``no-inspect``.
|
|
The default is ``irmc``.
|
|
|
|
.. note::
|
|
:ironic-inspector-doc:`Ironic Inspector <>`
|
|
needs to be present and configured to use ``inspector`` as the
|
|
inspect interface.
|
|
|
|
* management
|
|
Supports only ``irmc``.
|
|
|
|
* power
|
|
Supports ``irmc``, which enables power control via ServerView Common
|
|
Command Interface (SCCI), by default. Also supports ``ipmitool``.
|
|
|
|
* raid
|
|
Supports ``irmc``, ``no-raid`` and ``agent``.
|
|
The default is ``no-raid``.
|
|
|
|
For other hardware interfaces, ``irmc`` hardware type supports the
|
|
Bare Metal reference interfaces. For more details about the hardware
|
|
interfaces and how to enable the desired ones, see
|
|
:ref:`enable-hardware-interfaces`.
|
|
|
|
Here is a complete configuration example with most of the supported hardware
|
|
interfaces enabled for ``irmc`` hardware type.
|
|
|
|
.. code-block:: ini
|
|
|
|
[DEFAULT]
|
|
enabled_hardware_types = irmc
|
|
enabled_bios_interfaces = irmc
|
|
enabled_boot_interfaces = irmc-virtual-media,irmc-pxe
|
|
enabled_console_interfaces = ipmitool-socat,ipmitool-shellinabox,no-console
|
|
enabled_deploy_interfaces = iscsi,direct
|
|
enabled_inspect_interfaces = irmc,inspector,no-inspect
|
|
enabled_management_interfaces = irmc
|
|
enabled_network_interfaces = flat,neutron
|
|
enabled_power_interfaces = irmc
|
|
enabled_raid_interfaces = no-raid,irmc
|
|
enabled_storage_interfaces = noop,cinder
|
|
enabled_vendor_interfaces = no-vendor,ipmitool
|
|
|
|
Here is a command example to enroll a node with ``irmc`` hardware type.
|
|
|
|
.. code-block:: console
|
|
|
|
openstack baremetal node create \
|
|
--bios-interface irmc \
|
|
--boot-interface irmc-pxe \
|
|
--deploy-interface direct \
|
|
--inspect-interface irmc \
|
|
--raid-interface irmc
|
|
|
|
Node configuration
|
|
^^^^^^^^^^^^^^^^^^
|
|
|
|
* Each node is configured for ``irmc`` hardware type by setting the following
|
|
ironic node object's properties:
|
|
|
|
- ``driver_info/irmc_address`` property to be ``IP address`` or
|
|
``hostname`` of the iRMC.
|
|
- ``driver_info/irmc_username`` property to be ``username`` for
|
|
the iRMC with administrator privileges.
|
|
- ``driver_info/irmc_password`` property to be ``password`` for
|
|
irmc_username.
|
|
- ``properties/capabilities`` property to be ``boot_mode:uefi`` if
|
|
UEFI boot is required.
|
|
- ``properties/capabilities`` property to be ``secure_boot:true`` if
|
|
UEFI Secure Boot is required. Please refer to `UEFI Secure Boot Support`_
|
|
for more information.
|
|
|
|
* The following properties are also required if ``irmc-virtual-media`` boot
|
|
interface is used:
|
|
|
|
- ``driver_info/irmc_deploy_iso`` property to be either deploy iso
|
|
file name, Glance UUID, or Image Service URL.
|
|
- ``instance info/irmc_boot_iso`` property to be either boot iso
|
|
file name, Glance UUID, or Image Service URL. This is optional
|
|
property when ``boot_option`` is set to ``netboot``.
|
|
|
|
* All of the nodes are configured by setting the following configuration
|
|
options in the ``[irmc]`` section of ``/etc/ironic/ironic.conf``:
|
|
|
|
- ``port``: Port to be used for iRMC operations; either 80
|
|
or 443. The default value is 443. Optional.
|
|
- ``auth_method``: Authentication method for iRMC operations;
|
|
either ``basic`` or ``digest``. The default value is ``basic``. Optional.
|
|
- ``client_timeout``: Timeout (in seconds) for iRMC
|
|
operations. The default value is 60. Optional.
|
|
- ``sensor_method``: Sensor data retrieval method; either
|
|
``ipmitool`` or ``scci``. The default value is ``ipmitool``. Optional.
|
|
|
|
* The following options are required if ``irmc-virtual-media`` boot
|
|
interface is enabled:
|
|
|
|
- ``remote_image_share_root``: Ironic conductor node's ``NFS`` or
|
|
``CIFS`` root path. The default value is ``/remote_image_share_root``.
|
|
- ``remote_image_server``: IP of remote image server.
|
|
- ``remote_image_share_type``: Share type of virtual media, either
|
|
``NFS`` or ``CIFS``. The default is ``CIFS``.
|
|
- ``remote_image_share_name``: share name of ``remote_image_server``.
|
|
The default value is ``share``.
|
|
- ``remote_image_user_name``: User name of ``remote_image_server``.
|
|
- ``remote_image_user_password``: Password of ``remote_image_user_name``.
|
|
- ``remote_image_user_domain``: Domain name of ``remote_image_user_name``.
|
|
|
|
* The following options are required if ``irmc`` inspect interface is enabled:
|
|
|
|
- ``snmp_version``: SNMP protocol version; either ``v1``, ``v2c`` or
|
|
``v3``. The default value is ``v2c``. Optional.
|
|
- ``snmp_port``: SNMP port. The default value is ``161``. Optional.
|
|
- ``snmp_community``: SNMP community required for versions ``v1``
|
|
and ``v2c``. The default value is ``public``. Optional.
|
|
- ``snmp_security``: SNMP security name required for version ``v3``.
|
|
Optional.
|
|
|
|
* Each node can be further configured by setting the following ironic
|
|
node object's properties which override the parameter values in
|
|
``[irmc]`` section of ``/etc/ironic/ironic.conf``:
|
|
|
|
- ``driver_info/irmc_port`` property overrides ``port``.
|
|
- ``driver_info/irmc_auth_method`` property overrides ``auth_method``.
|
|
- ``driver_info/irmc_client_timeout`` property overrides ``client_timeout``.
|
|
- ``driver_info/irmc_sensor_method`` property overrides ``sensor_method``.
|
|
- ``driver_info/irmc_snmp_version`` property overrides ``snmp_version``.
|
|
- ``driver_info/irmc_snmp_port`` property overrides ``snmp_port``.
|
|
- ``driver_info/irmc_snmp_community`` property overrides ``snmp_community``.
|
|
- ``driver_info/irmc_snmp_security`` property overrides ``snmp_security``.
|
|
|
|
Optional functionalities for the ``irmc`` hardware type
|
|
=======================================================
|
|
|
|
UEFI Secure Boot Support
|
|
^^^^^^^^^^^^^^^^^^^^^^^^
|
|
The hardware type ``irmc`` supports secure boot deploy.
|
|
|
|
.. warning::
|
|
Secure boot feature is not supported with ``pxe`` boot interface.
|
|
|
|
The UEFI secure boot can be configured by adding ``secure_boot`` parameter,
|
|
which is a boolean value. Enabling the secure boot is different when
|
|
Bare Metal service is used with Compute service or without Compute service. The
|
|
following sections describe both methods:
|
|
|
|
* Enabling secure boot with Compute service:
|
|
To enable secure boot we need to set a capability on the bare metal node
|
|
and the bare metal flavor, for example::
|
|
|
|
openstack baremetal node set <node-uuid> --property capabilities='secure_boot:true'
|
|
openstack flavor set FLAVOR-NAME --property capabilities:secure_boot="true"
|
|
|
|
* Enabling secure boot without Compute service:
|
|
Since adding capabilities to the node's properties is only used by the nova
|
|
scheduler to perform more advanced scheduling of instances, we need
|
|
to enable secure boot without nova, for example::
|
|
|
|
openstack baremetal node set <node-uuid> --instance-info capabilities='{"secure_boot": "true"}'
|
|
|
|
.. _irmc_node_cleaning:
|
|
|
|
Node Cleaning Support
|
|
^^^^^^^^^^^^^^^^^^^^^
|
|
The ``irmc`` hardware type supports node cleaning.
|
|
For more information on node cleaning, see :ref:`cleaning`.
|
|
|
|
Supported **Automated** Cleaning Operations
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The automated cleaning operations supported are:
|
|
|
|
* ``restore_irmc_bios_config``:
|
|
Restores BIOS settings on a baremetal node from backup data. If this
|
|
clean step is enabled, the BIOS settings of a baremetal node will be
|
|
backed up automatically before the deployment. By default, this clean
|
|
step is disabled with priority ``0``. Set its priority to a positive
|
|
integer to enable it. The recommended value is ``10``.
|
|
|
|
.. warning::
|
|
``pxe`` boot interface, when used with ``irmc`` hardware type, does
|
|
not support this clean step. If uses ``irmc`` hardware type, it is
|
|
required to select ``irmc-pxe`` or ``irmc-virtual-media`` as the
|
|
boot interface in order to make this clean step work.
|
|
|
|
|
|
Configuration options for the automated cleaning steps are listed under
|
|
``[irmc]`` section in ironic.conf ::
|
|
|
|
clean_priority_restore_irmc_bios_config = 0
|
|
|
|
For more information on node automated cleaning, see :ref:`automated_cleaning`
|
|
|
|
Boot from Remote Volume
|
|
^^^^^^^^^^^^^^^^^^^^^^^
|
|
The ``irmc`` hardware type supports the generic iPXE-based remote volume
|
|
booting when using the following boot interfaces:
|
|
|
|
* ``irmc-pxe``
|
|
* ``pxe``
|
|
|
|
In addition, the ``irmc`` hardware type supports remote volume booting without
|
|
iPXE. This is available when using the ``irmc-virtual-media`` boot interface.
|
|
This feature configures a node to boot from a remote volume by using the API
|
|
of iRMC. It supports iSCSI and FibreChannel.
|
|
|
|
Configuration
|
|
~~~~~~~~~~~~~
|
|
|
|
In addition to the configuration for generic drivers to
|
|
:ref:`remote volume boot <boot-from-volume>`,
|
|
the iRMC driver requires the following configuration:
|
|
|
|
* It is necessary to set physical port IDs to network ports and volume
|
|
connectors. All cards including those not used for volume boot should be
|
|
registered.
|
|
|
|
The format of a physical port ID is: ``<Card Type><Slot No>-<Port No>`` where:
|
|
|
|
- ``<Card Type>``: could be ``LAN``, ``FC`` or ``CNA``
|
|
- ``<Slot No>``: 0 indicates onboard slot. Use 1 to 9 for add-on slots.
|
|
- ``<Port No>``: A port number starting from 1.
|
|
|
|
These IDs are specified in a node's ``driver_info[irmc_pci_physical_ids]``.
|
|
This value is a dictionary. The key is the UUID of a resource (Port or Volume
|
|
Connector) and its value is the physical port ID. For example::
|
|
|
|
{
|
|
"1ecd14ee-c191-4007-8413-16bb5d5a73a2":"LAN0-1",
|
|
"87f6c778-e60e-4df2-bdad-2605d53e6fc0":"CNA1-1"
|
|
}
|
|
|
|
It can be set with the following command::
|
|
|
|
openstack baremetal node set $NODE_UUID \
|
|
--driver-info irmc_pci_physical_ids={} \
|
|
--driver-info irmc_pci_physical_ids/$PORT_UUID=LAN0-1 \
|
|
--driver-info irmc_pci_physical_ids/$VOLUME_CONNECTOR_UUID=CNA1-1
|
|
|
|
* For iSCSI boot, volume connectors with both types ``iqn`` and ``ip`` are
|
|
required. The configuration with DHCP is not supported yet.
|
|
|
|
* For iSCSI, the size of the storage network is needed. This value should be
|
|
specified in a node's ``driver_info[irmc_storage_network_size]``. It must be
|
|
a positive integer < 32.
|
|
For example, if the storage network is 10.2.0.0/22, use the following
|
|
command::
|
|
|
|
openstack baremetal node set $NODE_UUID --driver-info irmc_storage_network_size=22
|
|
|
|
Supported hardware
|
|
~~~~~~~~~~~~~~~~~~
|
|
|
|
The driver supports the PCI controllers, Fibrechannel Cards, Converged Network
|
|
Adapters supported by
|
|
`Fujitsu ServerView Virtual-IO Manager <http://www.fujitsu.com/fts/products/computing/servers/primergy/management/primergy-blade-server-io-virtualization.html>`_.
|
|
|
|
Hardware Inspection Support
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
The ``irmc`` hardware type provides the iRMC-specific hardware inspection
|
|
with ``irmc`` inspect interface.
|
|
|
|
.. note::
|
|
SNMP requires being enabled in ServerView® iRMC S4 Web Server(Network
|
|
Settings\SNMP section).
|
|
|
|
Configuration
|
|
~~~~~~~~~~~~~
|
|
|
|
The Hardware Inspection Support in the iRMC driver requires the following
|
|
configuration:
|
|
|
|
* It is necessary to set ironic configuration with ``gpu_ids`` and
|
|
``fpga_ids`` options in ``[irmc]`` section.
|
|
|
|
``gpu_ids`` and ``fpga_ids`` are lists of ``<vendorID>/<deviceID>`` where:
|
|
|
|
- ``<vendorID>``: 4 hexadecimal digits starts with '0x'.
|
|
- ``<deviceID>``: 4 hexadecimal digits starts with '0x'.
|
|
|
|
Here are sample values for ``gpu_ids`` and ``fpga_ids``::
|
|
|
|
gpu_ids = 0x1000/0x0079,0x2100/0x0080
|
|
fpga_ids = 0x1000/0x005b,0x1100/0x0180
|
|
|
|
* The python-scciclient package requires pyghmi version >= 1.0.22 and pysnmp
|
|
version >= 4.2.3. They are used by the conductor service on the conductor.
|
|
The latest version of pyghmi can be downloaded from `here
|
|
<https://pypi.org/project/pyghmi/>`__
|
|
and pysnmp can be downloaded from `here
|
|
<https://pypi.org/project/pysnmp/>`__.
|
|
|
|
Supported properties
|
|
~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The inspection process will discover the following essential properties
|
|
(properties required for scheduling deployment):
|
|
|
|
* ``memory_mb``: memory size
|
|
|
|
* ``cpus``: number of cpus
|
|
|
|
* ``cpu_arch``: cpu architecture
|
|
|
|
* ``local_gb``: disk size
|
|
|
|
Inspection can also discover the following extra capabilities for iRMC
|
|
driver:
|
|
|
|
* ``irmc_firmware_version``: iRMC firmware version
|
|
|
|
* ``rom_firmware_version``: ROM firmware version
|
|
|
|
* ``trusted_boot``: The flag whether TPM(Trusted Platform Module) is
|
|
supported by the server. The possible values are 'True' or 'False'.
|
|
|
|
* ``server_model``: server model
|
|
|
|
* ``pci_gpu_devices``: number of gpu devices connected to the bare metal.
|
|
|
|
Inspection can also set/unset node's traits with the following cpu type for
|
|
iRMC driver:
|
|
|
|
* ``CUSTOM_CPU_FPGA``: The bare metal contains fpga cpu type.
|
|
|
|
.. note::
|
|
|
|
* The disk size is returned only when eLCM License for FUJITSU PRIMERGY
|
|
servers is activated. If the license is not activated, then Hardware
|
|
Inspection will fail to get this value.
|
|
* Before inspecting, if the server is power-off, it will be turned on
|
|
automatically. System will wait for a few second before start
|
|
inspecting. After inspection, power status will be restored to the
|
|
previous state.
|
|
|
|
The operator can specify these capabilities in compute service flavor, for
|
|
example::
|
|
|
|
openstack flavor set baremetal-flavor-name --property capabilities:irmc_firmware_version="iRMC S4-8.64F"
|
|
|
|
openstack flavor set baremetal-flavor-name --property capabilities:server_model="TX2540M1F5"
|
|
|
|
openstack flavor set baremetal-flavor-name --property capabilities:pci_gpu_devices="1"
|
|
|
|
See :ref:`capabilities-discovery` for more details and examples.
|
|
|
|
The operator can add a trait in compute service flavor, for example::
|
|
|
|
openstack baremetal node add trait $NODE_UUID CUSTOM_CPU_FPGA
|
|
|
|
A valid trait must be no longer than 255 characters. Standard traits are
|
|
defined in the os_traits library. A custom trait must start with the prefix
|
|
``CUSTOM_`` and use the following characters: A-Z, 0-9 and _.
|
|
|
|
RAID configuration Support
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
The ``irmc`` hardware type provides the iRMC RAID configuration with ``irmc``
|
|
raid interface.
|
|
|
|
.. note::
|
|
|
|
* RAID implementation for ``irmc`` hardware type is based on eLCM license
|
|
and SDCard. Otherwise, SP(Service Platform) in lifecycle management
|
|
must be available.
|
|
* RAID implementation only supported for RAIDAdapter 0 in Fujitsu Servers.
|
|
|
|
Configuration
|
|
~~~~~~~~~~~~~
|
|
|
|
The RAID configuration Support in the iRMC drivers requires the following
|
|
configuration:
|
|
|
|
* It is necessary to set ironic configuration into Node with
|
|
JSON file option::
|
|
|
|
$ openstack baremetal node set <node-uuid-or-name> \
|
|
--target-raid-config <JSON file containing target RAID configuration>
|
|
|
|
Here is some sample values for JSON file::
|
|
|
|
{
|
|
"logical_disks": [
|
|
{
|
|
"size_gb": 1000,
|
|
"raid_level": "1"
|
|
]
|
|
}
|
|
|
|
or::
|
|
|
|
{
|
|
"logical_disks": [
|
|
{
|
|
"size_gb": 1000,
|
|
"raid_level": "1",
|
|
"controller": "FTS RAID Ctrl SAS 6G 1GB (D3116C) (0)",
|
|
"physical_disks": [
|
|
"0",
|
|
"1"
|
|
]
|
|
}
|
|
]
|
|
}
|
|
|
|
.. note::
|
|
|
|
RAID 1+0 and 5+0 in iRMC driver does not support property ``physical_disks``
|
|
in ``target_raid_config`` during create raid configuration yet. See
|
|
following example::
|
|
|
|
{
|
|
"logical_disks":
|
|
[
|
|
{
|
|
"size_gb": "MAX",
|
|
"raid_level": "1+0"
|
|
}
|
|
]
|
|
}
|
|
|
|
See :ref:`raid` for more details and examples.
|
|
|
|
Supported properties
|
|
~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The RAID configuration using iRMC driver supports following parameters in
|
|
JSON file:
|
|
|
|
* ``size_gb``: is mandatory properties in Ironic.
|
|
* ``raid_level``: is mandatory properties in Ironic. Currently, iRMC Server
|
|
supports following RAID levels: 0, 1, 5, 6, 1+0 and 5+0.
|
|
* ``controller``: is name of the controller as read by the RAID interface.
|
|
* ``physical_disks``: are specific values for each raid array in
|
|
LogicalDrive which operator want to set them along with ``raid_level``.
|
|
|
|
The RAID configuration is supported as a manual cleaning step.
|
|
|
|
.. note::
|
|
|
|
* iRMC server will power-on after create/delete raid configuration is
|
|
applied, FGI (Foreground Initialize) will process raid configuration in
|
|
iRMC server, thus the operation will completed upon power-on and power-off
|
|
when created RAID on iRMC server.
|
|
|
|
See :ref:`raid` for more details and examples.
|
|
|
|
BIOS configuration Support
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
The ``irmc`` hardware type provides the iRMC BIOS configuration with ``irmc``
|
|
bios interface.
|
|
|
|
.. warning::
|
|
``irmc`` bios interface does not support ``factory_reset``.
|
|
|
|
|
|
Configuration
|
|
~~~~~~~~~~~~~
|
|
|
|
The BIOS configuration in the iRMC driver supports the following settings:
|
|
|
|
- ``boot_option_filter``: Specifies from which drives can be booted. This
|
|
supports following options: ``UefiAndLegacy``, ``LegacyOnly``, ``UefiOnly``.
|
|
- ``check_controllers_health_status_enabled``: The UEFI FW checks the
|
|
controller health status. This supports following options: ``true``, ``false``.
|
|
- ``cpu_active_processor_cores``: The number of active processor cores 1...n.
|
|
Option 0 indicates that all available processor cores are active.
|
|
- ``cpu_adjacent_cache_line_prefetch_enabled``: The processor loads the requested
|
|
cache line and the adjacent cache line. This supports following options:
|
|
``true``, ``false``.
|
|
- ``cpu_vt_enabled``: Supports the virtualization of platform hardware and
|
|
several software environments, based on Virtual Machine Extensions to
|
|
support the use of several software environments using virtual computers.
|
|
This supports following options: ``true``, ``false``.
|
|
- ``flash_write_enabled``: The system BIOS can be written. Flash BIOS update
|
|
is possible. This supports following options: ``true``, ``false``.
|
|
- ``hyper_threading_enabled``: Hyper-threading technology allows a single
|
|
physical processor core to appear as several logical processors. This
|
|
supports following options: ``true``, ``false``.
|
|
- ``keep_void_boot_options_enabled``: Boot Options will not be removed from
|
|
"Boot Option Priority" list. This supports following options: ``true``,
|
|
``false``.
|
|
- ``launch_csm_enabled``: Specifies whether the Compatibility Support Module
|
|
(CSM) is executed. This supports following options: ``true``, ``false``.
|
|
- ``os_energy_performance_override_enabled``: Prevents the OS from overruling
|
|
any energy efficiency policy setting of the setup. This supports following
|
|
options: ``true``, ``false``.
|
|
- ``pci_aspm_support``: Active State Power Management (ASPM) is used to
|
|
power-manage the PCI Express links, thus consuming less power. This
|
|
supports following options: ``Disabled``, ``Auto``, ``L0Limited``,
|
|
``L1only``, ``L0Force``.
|
|
- ``pci_above_4g_decoding_enabled``: Specifies if memory resources above the
|
|
4GB address boundary can be assigned to PCI devices. This supports
|
|
following options: ``true``, ``false``.
|
|
- ``power_on_source``: Specifies whether the switch on sources for the system
|
|
are managed by the BIOS or the ACPI operating system. This supports
|
|
following options: ``BiosControlled``, ``AcpiControlled``.
|
|
- ``single_root_io_virtualization_support_enabled``: Single Root IO
|
|
Virtualization Support is active. This supports following
|
|
options: ``true``, ``false``.
|
|
|
|
The BIOS configuration is supported as a manual cleaning step. See :ref:`bios`
|
|
for more details and examples.
|
|
|
|
Supported platforms
|
|
===================
|
|
This driver supports FUJITSU PRIMERGY BX S4 or RX S8 servers and above.
|
|
|
|
- PRIMERGY BX920 S4
|
|
- PRIMERGY BX924 S4
|
|
- PRIMERGY RX300 S8
|
|
|
|
When ``irmc`` power interface is used, Soft Reboot (Graceful Reset) and Soft
|
|
Power Off (Graceful Power Off) are only available if
|
|
`ServerView agents <http://manuals.ts.fujitsu.com/index.php?id=5406-5873-5925-5945-16159>`_
|
|
are installed. See `iRMC S4 Manual <http://manuals.ts.fujitsu.com/index.php?id=5406-5873-5925-5988>`_
|
|
for more details.
|
|
|
|
RAID configuration feature supports FUJITSU PRIMERGY servers with
|
|
RAID-Ctrl-SAS-6G-1GB(D3116C) controller and above.
|
|
For detail supported controller with OOB-RAID configuration, please see
|
|
`the whitepaper for iRMC RAID configuration <http://manuals.ts.fujitsu.com/file/12073/wp-svs-oob-raid-hdd-en.pdf>`_.
|