e55a83e832
Move the public API out of oslo.messaging to oslo_messaging. Retain the ability to import from the old namespace package for backwards compatibility for this release cycle. bp/drop-namespace-packages Co-authored-by: Mehdi Abaakouk <mehdi.abaakouk@enovance.com> Change-Id: Ia562010c152a214f1c0fed767c82022c7c2c52e7
55 lines
2.2 KiB
ReStructuredText
55 lines
2.2 KiB
ReStructuredText
------
|
|
Target
|
|
------
|
|
|
|
.. currentmodule:: oslo_messaging
|
|
|
|
.. autoclass:: Target
|
|
|
|
===============
|
|
Target Versions
|
|
===============
|
|
|
|
Target version numbers take the form Major.Minor. For a given message with
|
|
version X.Y, the server must be marked as able to handle messages of version
|
|
A.B, where A == X and B >= Y.
|
|
|
|
The Major version number should be incremented for an almost completely new
|
|
API. The Minor version number would be incremented for backwards compatible
|
|
changes to an existing API. A backwards compatible change could be something
|
|
like adding a new method, adding an argument to an existing method (but not
|
|
requiring it), or changing the type for an existing argument (but still
|
|
handling the old type as well).
|
|
|
|
If no version is specified it defaults to '1.0'.
|
|
|
|
In the case of RPC, if you wish to allow your server interfaces to evolve such
|
|
that clients do not need to be updated in lockstep with the server, you should
|
|
take care to implement the server changes in a backwards compatible and have
|
|
the clients specify which interface version they require for each method.
|
|
|
|
Adding a new method to an endpoint is a backwards compatible change and the
|
|
version attribute of the endpoint's target should be bumped from X.Y to X.Y+1.
|
|
On the client side, the new RPC invocation should have a specific version
|
|
specified to indicate the minimum API version that must be implemented for the
|
|
method to be supported. For example::
|
|
|
|
def get_host_uptime(self, ctxt, host):
|
|
cctxt = self.client.prepare(server=host, version='1.1')
|
|
return cctxt.call(ctxt, 'get_host_uptime')
|
|
|
|
In this case, version '1.1' is the first version that supported the
|
|
get_host_uptime() method.
|
|
|
|
Adding a new parameter to an RPC method can be made backwards compatible. The
|
|
endpoint version on the server side should be bumped. The implementation of
|
|
the method must not expect the parameter to be present.::
|
|
|
|
def some_remote_method(self, arg1, arg2, newarg=None):
|
|
# The code needs to deal with newarg=None for cases
|
|
# where an older client sends a message without it.
|
|
pass
|
|
|
|
On the client side, the same changes should be made as in example 1. The
|
|
minimum version that supports the new parameter should be specified.
|