Outlet Temperature Based Strategy
|
|
==========================================
|
|
|
|
https://blueprints.launchpad.net/watcher/+spec/outlet-temperature-based-strategy
|
|
|
|
Outlet(Exhaust Air) temperature is a new thermal telemetry which can be used
|
|
to measure the server's thermal/workload status.
|
|
|
|
This spec proposes a new Watcher migration strategy based on the outlet
|
|
temperature of servers. This strategy makes decisions to migrate workloads
|
|
to the servers with good thermal condition (lowest outlet temperature) when
|
|
the outlet temperature of source servers reach a configurable threshold.
|
|
|
|
Note: "server" in this document means "hypervisor".
|
|
|
|
Problem description
|
|
===================
|
|
|
|
In current Data Center infrastructure, the cooling air supply to servers can
|
|
be different. When a server is overloaded or the supply air is too hot, the
|
|
outlet temperature telemetry can be used to detect the problem. In order to
|
|
have the server in a reliable thermal condition, some of the server's
|
|
workloads should be migrated to other server with safer thermal conditions.
|
|
|
|
Use Cases
|
|
----------
|
|
|
|
As an administrator, I want to be able to trigger an audit that controls the
|
|
temperature and perform workload load balancing.
|
|
|
|
In order to :
|
|
|
|
* Reduce the total power consumption spent on cooling.
|
|
|
|
* Increase the lifespan of the data center because cooling effectiveness is a
|
|
first order factor.
|
|
|
|
Project Priority
|
|
-----------------
|
|
|
|
Not relevant because Watcher is not in the big tent so far.
|
|
|
|
Proposed change
|
|
===============
|
|
|
|
Watcher already has its decision framework, so this strategy should be a new
|
|
class which extend the base strategy class.
|
|
|
|
* Set the threshold in 2 steps : hard coded first, then through the template.
|
|
|
|
* Create a new Python class to extend the "BaseStrategy" class.
|
|
|
|
* Use the Ceilometer client to get Outlet temperature metrics of hypervisors.
|
|
|
|
* Use the Nova objects framework to get free CPU/Memory/Disk of hypervisors.
|
|
|
|
* An algorithm to detect if the threshold of Outlet temperature has been
|
|
reached and to choose the migration target server. It will filter the viable
|
|
targets according to the free resource information of hypervisors from
|
|
previous step.
|
|
|
|
|
|
Alternatives
|
|
------------
|
|
|
|
No alternative
|
|
|
|
Data model impact
|
|
-----------------
|
|
|
|
None
|
|
|
|
REST API impact
|
|
---------------
|
|
|
|
None
|
|
|
|
Security impact
|
|
---------------
|
|
|
|
None
|
|
|
|
Notifications impact
|
|
--------------------
|
|
|
|
None
|
|
|
|
Other end user impact
|
|
---------------------
|
|
|
|
None
|
|
|
|
Performance Impact
|
|
------------------
|
|
|
|
There used to be some performance issues regarding the query of metrics from
|
|
the Ceilometer database. This is one of the reason why it was rarely used in
|
|
production environment. These issues may now be solved thanks to an
|
|
abstraction layer which enables anybody to change the underlying metrics
|
|
storage backend easily.
|
|
There is also a performance issue when you query the Nova DB to get cpu
|
|
usage metrics.
|
|
|
|
Other deployer impact
|
|
---------------------
|
|
|
|
None
|
|
|
|
Developer impact
|
|
----------------
|
|
|
|
None
|
|
|
|
|
|
Implementation
|
|
==============
|
|
|
|
Assignee(s)
|
|
-----------
|
|
|
|
Primary assignee:
|
|
<junjie-huang>
|
|
|
|
|
|
Work Items
|
|
----------
|
|
|
|
1. function to use Ceilometer client to get outlet temperature of hypervisors.
|
|
|
|
2. function to filter servers by Nova basic metrics(free CPU/Memory/Disk)
|
|
|
|
3. Rewrite execute function to add the algorithm to detect if the threshold
|
|
of outlet T has been reached and choose the target hypervisor, generate
|
|
action plan.
|
|
|
|
|
|
Dependencies
|
|
============
|
|
|
|
* https://wiki.openstack.org/wiki/Ceilometer/blueprints/APIv2
|
|
|
|
* https://blueprints.launchpad.net/ceilometer/+spec/api-v2-improvement
|
|
|
|
* https://docs.openstack.org/admin-guide/telemetry-measurements.html
|
|
|
|
* https://docs.openstack.org/developer/python-novaclient/api.html
|
|
|
|
|
|
Testing
|
|
=======
|
|
|
|
Unit tests and functional test, will use a fake metrics set for running
|
|
functional test.
|
|
|
|
|
|
Documentation Impact
|
|
====================
|
|
|
|
A documentation explaining how to use this new optimization strategy.
|
|
|
|
|
|
References
|
|
==========
|
|
|
|
http://www.intel.com/content/www/us/en/servers/ipmi/ipmi-home.html
|
|
|
|
|
|
History
|
|
=======
|
|
|
|
None
|