e7784ed9f4
When execute tox -e docs, docs commands failed ERROR occured. all the errors are concerns D000: Unexpected indentation, This change is to fix it. Change-Id: Ie811edb290bba7f46a3672d088cf86b7a69e1db6 Closes-bug: #1715613
271 lines
9.1 KiB
ReStructuredText
271 lines
9.1 KiB
ReStructuredText
..
|
|
This work is licensed under a Creative Commons Attribution 3.0 Unported
|
|
License.
|
|
|
|
https://creativecommons.org/licenses/by/3.0/legalcode
|
|
|
|
===============================
|
|
PCI passthrough device modeling
|
|
===============================
|
|
|
|
Related Launchpad Blueprint:
|
|
https://blueprints.launchpad.net/zun/+spec/container-pci-device-modeling
|
|
|
|
PCI passthrough enables full access and direct control of a physical PCI
|
|
device in a Zun container. With PCI passthrough, the full physical device
|
|
is assigned to only one container and cannot be shared. This mechanism is
|
|
generic for any kind of PCI devices. For example, it runs with a Network
|
|
Interface Card (NIC), Graphics Processing Unit (GPU), or any other devices
|
|
that can be attached to a PCI bus. To properly use the devices, containers
|
|
are required to install the correct driver of the device.
|
|
|
|
Some PCI devices provide Single Root I/O Virtualization and Sharing (SR-IOV)
|
|
capabilities to share the PCI device among different VMs or containers. When
|
|
SR-IOV is used, a physical device is virtualized and appears as multiple PCI
|
|
devices. Virtual PCI devices are assigned to the same or different containers.
|
|
|
|
Since release Ocata, Openstack Nova enables flavor-based PCI-passthough device
|
|
management. This design will not depend on the Nova's implementation of PCI-
|
|
passthough work. However the design and implementation in Zun will refer to
|
|
the existing of Nova work and try to be consistent with Nova's implementation.
|
|
|
|
Problem description
|
|
===================
|
|
Currently, Zun scheduler can only schedule work loads with requests of regular
|
|
compute resources, such as CPUs, RAMs. There are some emerging use cases
|
|
requiring containers to access resources such as GPUs, NICs and so on. PCI
|
|
passthrough and SR-IOV are the common technology to enable such use cases.
|
|
To support the new use cases, the new resources will be added to Zun compute
|
|
resource model, and allow Zun scheduler to place the work load according to
|
|
the availability of the resources.
|
|
|
|
Proposed change
|
|
===============
|
|
1. Introduce a new configuration to abstract the PCI devices at Zun Compute.
|
|
A new PCI passthrough whitelist configuration will allow cloud
|
|
administrators to explicitly define a list PCI devices to be available
|
|
for Zun Compute services. The whitelist of PCI devices should be common
|
|
for both network PCI devices and other compute or storage PCI devices.
|
|
The PCI whitelist can be implemented exactly as Nova[1]:
|
|
In zun.conf, whitelist entries are defined as the following:
|
|
|
|
::
|
|
|
|
pci_passthrough_whitelist = {<entry>}
|
|
Each whitelist entry is defined in the format:
|
|
["vendor_id": "<id>",]
|
|
["product_id": "<id>",]
|
|
["address": "[[[[<domain>]:]<bus>]:][<slot>][.[<function>]]" |
|
|
"devname": "PCI Device Name",]
|
|
["tag":"<tag_value>",]
|
|
|
|
The valid key values are:
|
|
"vendor_id": Vendor ID of the device in hexadecimal.
|
|
"product_id": Product ID of the device in hexadecimal.
|
|
"address": PCI address of the device.
|
|
"devname": Device name of the device (for e.g. interface name). Not all
|
|
PCI devices have a name.
|
|
"<tag>": Additional <tag> and <tag_value> used for matching PCI devices.
|
|
Supported <tag>: "physical_network". The pre-defined tag
|
|
"physical_network" is used to define the physical network, that
|
|
the SR-IOV NIC devices are attached to.
|
|
|
|
2. Introduce a new configuration pci alias to allow zun to specify the PCI
|
|
device without needing to repeat all the PCI property requirement.
|
|
For example,
|
|
|
|
::
|
|
|
|
alias = {
|
|
"name": "QuickAssist",
|
|
"product_id": "0443",
|
|
"vendor_id": "8086",
|
|
"device_type": "type-PCI"
|
|
}
|
|
|
|
defines an alias for the Intel QuickAssist card. Valid key values are
|
|
"name": Name of the PCI alias.
|
|
"product_id": Product ID of the device in hexadecimal.
|
|
"vendor_id": Vendor ID of the device in hexadecimal.
|
|
"device_type": Type of PCI device. Valid values are: "type-PCI",
|
|
"type-PF" and "type-VF".
|
|
|
|
The typical workflow will be as following:
|
|
|
|
1. A cloud admin configures PCI-PASSTHROUGH alias at /etc/zun.conf on the
|
|
oepnstack controller nodes.
|
|
|
|
::
|
|
|
|
[default]
|
|
pci_alias = {
|
|
"name": "QuickAssist",
|
|
"product_id": "0443",
|
|
"vendor_id": "8086",
|
|
"device_type": "type-PCI"
|
|
}
|
|
|
|
2. Cloud admin enables the PCI-PASSTHROUGH filter to /etc/zun.conf at
|
|
openstack controller nodes.
|
|
|
|
::
|
|
|
|
scheduler_available_filters=zun.scheduler.filters.all_filters
|
|
scheduler_default_filters= ..., PciPassthroughFilter
|
|
|
|
3. Cloud admin restarts the Zun-API service to make the configuration
|
|
effective;
|
|
4. Cloud admin adds available PCI Passthrough devices to the whitelist of
|
|
/etc/zun.conf at Zun compute nodes. An example can be the following:
|
|
|
|
::
|
|
|
|
[default]
|
|
pci_passthrough_whitelist = {
|
|
"product_id": "0443",
|
|
"vendor_id": "8086",
|
|
"device_type": "type-PCI",
|
|
"address": ":0a:00."
|
|
}
|
|
All PCI devices matching the vendor_id and product_id are added to the pool
|
|
of PCI devices available for passthrough to Zun containers.
|
|
|
|
5. Cloud admin restarts Zun Compute service to make the configuration
|
|
effective.
|
|
6. Each Zun Compute service updates the PCI-Passthough devices' availability to
|
|
Zun Scheduler perioadially.
|
|
7. Cloud user creates a new container with request of a PCI-Passthrough
|
|
device. For example, the following command will create a test_QuickAssist
|
|
container with two PCI devices named "QuickAssist" attached. The design and
|
|
implementation details of creating a workload with PCI_Passthrough devices
|
|
are out of the scope of this design spec. Please refer to the other
|
|
blueprints (TBD) for more details.
|
|
|
|
$ zun create --pci_passthrough QuickAssist:1 test_QuickAssist
|
|
|
|
Alternatives
|
|
------------
|
|
It is a more desirable way to define workloads using flavors. PCI-Passthough
|
|
configurations, in particularly pci_alias can be included in the flavor
|
|
configuration [2][3]. Thus users will use the flavor to specify the PCI device
|
|
to be used for container.
|
|
Integration with OpenStack Cyborg is another mid to long term alternative[4].
|
|
Cyborg as a service for managing accelerators of any kind needs to cooperate
|
|
with Zun on two planes: first, Cyborg should inform Zun about the resources
|
|
through placement API[5], so that scheduler can leverage user request for
|
|
particular functionality into assignment of specific resource using resource
|
|
provider which possess an accelerator; second, Cyborg should be able to provide
|
|
information how Zun compute can attach particular resource to containers.
|
|
|
|
Data model impact
|
|
-----------------
|
|
- Introduce a new object list pci-alias, which is a list of alias object:
|
|
|
|
::
|
|
|
|
fields = {
|
|
"name" : fields.StringField(nullable=False),
|
|
"vendor_id": fields.StringField(nullable=False),
|
|
"product_id": fields.StringField(nullable=False),
|
|
"device_type": fields.StringField(nullable=False)
|
|
}
|
|
|
|
- Introduce a new field in the container object called 'pci-alias-usage',
|
|
for example:
|
|
"pci_alias_name": fields.StringField(nullable=False),
|
|
"count": fields.IntField(nullable=True)
|
|
|
|
- Add pci-devices to the compute_node object. Each pci-device should have
|
|
the following fields as an example:
|
|
|
|
::
|
|
|
|
{
|
|
"vendor_id": fields.StringField(nullable=False),
|
|
"product_id": fields.StringField(nullable=False),
|
|
"address": fields.StringField(nullable=True),
|
|
"devname": fields.StringField(nullable=True),
|
|
"physical_network": fields.StringField(nullable=True),
|
|
}
|
|
|
|
REST API impact
|
|
---------------
|
|
None
|
|
|
|
Security impact
|
|
---------------
|
|
None
|
|
|
|
Notifications impact
|
|
--------------------
|
|
None
|
|
|
|
Other end user impact
|
|
---------------------
|
|
None
|
|
|
|
|
|
Performance Impact
|
|
------------------
|
|
None
|
|
|
|
|
|
Other deployer impact
|
|
---------------------
|
|
None
|
|
|
|
|
|
Developer impact
|
|
----------------
|
|
None
|
|
|
|
|
|
Implementation
|
|
==============
|
|
|
|
|
|
Assignee(s)
|
|
-----------
|
|
|
|
Primary assignee:
|
|
|
|
Other contributors:
|
|
|
|
|
|
Work Items
|
|
----------
|
|
1. Implement codes to read and validate pci_alias configuration;
|
|
2. Implement codes to read and validate pci_whitelist configuration;
|
|
3. Implement new pci-alias model and the verify if a pci_alias match
|
|
a given pci_whitelist entry upon a new zun compute service available;
|
|
4. Implement unit/integration test.
|
|
|
|
Dependencies
|
|
============
|
|
The full function of enable Pci passthrough will depend on other component
|
|
in Zun or outside of Zun such as Neutron and Kuryr;
|
|
Support GPU PCI-PASSTHROUGH will require the support of NVIDIA docker run-time;
|
|
Support SR-IOV NIC PCI-PASSTHROUGH will require SR-IOV port binding from Kuryr.
|
|
|
|
Testing
|
|
=======
|
|
Each patch will have unit tests, and Tempest functional tests covered.
|
|
|
|
|
|
Documentation Impact
|
|
====================
|
|
A set of documentation for this new feature will be required.
|
|
|
|
References
|
|
==========
|
|
[1] https://docs.openstack.org/nova/latest/admin/pci-passthrough.html
|
|
|
|
[2] PCI flavor-based device assignment https://docs.google.com/
|
|
document/d/1vadqmurlnlvZ5bv3BlUbFeXRS_wh-dsgi5plSjimWjU
|
|
|
|
[3] https://wiki.openstack.org/wiki/PCI_passthrough_SRIOV_support
|
|
|
|
[4] https://review.openstack.org/#/c/448228/
|
|
|
|