Updates/additions to: -System Config PTP section -Guest Integration -Admin Tasks -Updates and Upgrades Additional examples for T-BC Incorporated patchset 3 review comments. Added Limitations section. Integrated patchset 5 comments. Remove PTP Instance Removal - moved to RNs. *Do not pick 100.019 alarm update to r6 Story: 2009130 Signed-off-by: Ron Stone <ronald.stone@windriver.com> Change-Id: Ibdf449fe1d7282302d9be6d90e1c1b6dd70456b4
1.5 KiB
1.5 KiB
Override Default Application Values
You can override default application values using the commands described in this section.
View existing values.
~(keystone_admin)]$ system helm-override-show ptp-notification ptp-notification notification
Create a yaml file and update the fields that require Helm overrides.
cat ~/override.yaml ptptracking: device: holdover_seconds: 25 poll_freq_seconds: 2
Apply the values.
Application values can be added by the user and applied, using the following commands.
Note
The application could be in the "uploaded" or "applied" state.
~(keystone_admin)]$ system helm-override-update ptp-notification ptp-notification notification -–values <override.yaml>
~(keystone_admin)]$ system application-apply ptp-notification
where the values are:
- simulated
-
value must be 'false' for a normal operation (used only for troubleshooting).
- holdover_seconds
-
value is the holdover time provided by the specification. The default is 15 seconds.
- poll_freq_seconds
-
is the frequency that the tracking function monitors the
ptp4l