docs/doc/source/admintasks/kubernetes/override-default-application-values.rst
Ron Stone 3b8299cf2c PTP GNSS and SyncE Support (dsR6*)
Updates/additions to:
-System Config PTP section
-Guest Integration
-Admin Tasks
-Updates and Upgrades
Additional examples for T-BC
Incorporated patchset 3 review comments.
Added Limitations section.
Integrated patchset 5 comments.
Remove PTP Instance Removal - moved to RNs.

*Do not pick 100.019 alarm update to r6

Story: 2009130

Signed-off-by: Ron Stone <ronald.stone@windriver.com>
Change-Id: Ibdf449fe1d7282302d9be6d90e1c1b6dd70456b4
2022-03-30 17:34:41 +00:00

1.5 KiB
Raw Blame History

Override Default Application Values

You can override default application values using the commands described in this section.

  1. View existing values.

    ~(keystone_admin)]$ system helm-override-show ptp-notification
    ptp-notification notification
  2. Create a yaml file and update the fields that require Helm overrides.

    cat ~/override.yaml
    ptptracking:
     device:
       holdover_seconds: 25
       poll_freq_seconds: 2
  3. Apply the values.

    Application values can be added by the user and applied, using the following commands.

    Note

    The application could be in the "uploaded" or "applied" state.

    ~(keystone_admin)]$ system helm-override-update ptp-notification ptp-notification notification -values <override.yaml>
    ~(keystone_admin)]$ system application-apply ptp-notification

    where the values are:

    simulated

    value must be 'false' for a normal operation (used only for troubleshooting).

    holdover_seconds

    value is the holdover time provided by the specification. The default is 15 seconds.

    poll_freq_seconds

    is the frequency that the tracking function monitors the ptp4l to derive the sync state. The default is 2 seconds.