.. ots1579702138430
.. _400-series-alarm-messages:
=========================
400 Series Alarm Messages
=========================
The system inventory and maintenance service reports system changes with
different degrees of severity. Use the reported alarms to monitor the overall
health of the system.
.. include:: ../../_includes/x00-series-alarm-messages.rest
.. _400-series-alarm-messages-table-zrd-tg5-v5:
.. list-table::
:widths: 6 25
:header-rows: 0
* - **Alarm ID: 400.003**
- License key is not installed; a valid license key is required for
operation.
or
License key has expired or is invalid; a valid license key is required
for operation.
or
Evaluation license key will expire on <date>; there are <num\_days> days
remaining in this evaluation.
or
Evaluation license key will expire on <date>; there is only 1 day
remaining in this evaluation.
* - Entity Instance:
- host=<hostname>
* - Degrade Affecting Severity:
- None
* - Severity:
- C\*
* - Proposed Repair Action
- Contact next level of support to obtain a new license key.
-----
.. list-table::
:widths: 6 25
:header-rows: 0
* - **Alarm ID: 400.005**
- Communication failure detected with peer over port <linux-ifname>.
or
Communication failure detected with peer over port <linux-ifname>
within the last 30 seconds.
* - Entity Instance:
- host=<hostname>.network=<mgmt \| oam \| cluster-host>
* - Degrade Affecting Severity:
- None
* - Severity:
- M\*
* - Proposed Repair Action
- Check cabling and far-end port configuration and status on adjacent
equipment.