Created 2 new topics in Node management - HW Acceleration Devices: - Configure NVIDIA GPU Operator for PCI Passthrough - Delete the GPU Operator Patch 4: Added NVIDIA information in Planning - Verified Comm HW Patch 5: Acted on Greg's comment Patch 6: updated Index as requested in review worked on comments from Ghada Patch 7 and 8: acted on Mary's comments Added 'release-caveat' Acted on Ron's comments Story: 2008434 Task: 42220 https://review.opendev.org/c/starlingx/docs/+/785251 Signed-off-by: Adil <mohamed.adilassakkali@windriver.com> Change-Id: I337e33e805d89621436b35c238aca800b0727e0b
191 lines
88 KiB
ReStructuredText
Executable File
191 lines
88 KiB
ReStructuredText
Executable File
|
|
.. svs1552672428539
|
|
.. _verified-commercial-hardware:
|
|
|
|
=======================================
|
|
Kubernetes Verified Commercial Hardware
|
|
=======================================
|
|
|
|
Verified and approved hardware components for use with |prod| are listed here.
|
|
|
|
.. _verified-commercial-hardware-verified-components:
|
|
|
|
.. table:: Table 1. Verified Components
|
|
:widths: auto
|
|
|
|
+--------------------------------------------------------------------------------+----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
|
|
| Component | Approved Hardware |
|
|
+================================================================================+========================================================================================================================================================================================================================================================================================================================================================================================================================================+
|
|
| Hardware Platforms | - Hewlett Packard Enterprise |
|
|
| | |
|
|
| | |
|
|
| | - HPE ProLiant DL360p Gen8 Server |
|
|
| | |
|
|
| | - HPE ProLiant DL360p Gen9 Server |
|
|
| | |
|
|
| | - HPE ProLiant DL360 Gen10 Server |
|
|
| | |
|
|
| | - HPE ProLiant DL380p Gen8 Server |
|
|
| | |
|
|
| | - HPE ProLiant DL380p Gen9 Server |
|
|
| | |
|
|
| | - HPE ProLiant ML350 Gen10 Server |
|
|
| | |
|
|
| | - c7000 Enclosure with HPE ProLiant BL460 Gen9 Server |
|
|
| | |
|
|
| | .. caution:: |
|
|
| | LAG support is dependent on the switch cards deployed with the c7000 enclosure. To determine whether LAG can be configured, consult the switch card documentation. |
|
|
| | |
|
|
| | - HPE ProLiant e910t Server Blade |
|
|
| | |
|
|
| | |
|
|
| | - Dell |
|
|
| | |
|
|
| | |
|
|
| | - Dell PowerEdge R430 |
|
|
| | |
|
|
| | - Dell PowerEdge R630 |
|
|
| | |
|
|
| | - Dell PowerEdge R640 |
|
|
| | |
|
|
| | - Dell PowerEdge R720 |
|
|
| | |
|
|
| | - Dell PowerEdge R730 |
|
|
| | |
|
|
| | - Dell PowerEdge R740 |
|
|
| | |
|
|
| | |
|
|
| | - Kontron Symkloud MS2920 |
|
|
| | |
|
|
| | .. note:: |
|
|
| | The Kontron platform does not support power ON/OFF or reset through the BMC interface on |prod|. As a result, it is not possible for the system to properly fence a node in the event of a management network isolation event. In order to mitigate this, hosted application auto recovery needs to be disabled. |
|
|
| | |
|
|
| | - ZTSystems Triton |
|
|
+--------------------------------------------------------------------------------+----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
|
|
| Supported Reference Platforms | - Intel Iron Pass |
|
|
| | |
|
|
| | - Intel Canoe Pass |
|
|
| | |
|
|
| | - Intel Grizzly Pass |
|
|
| | |
|
|
| | - Intel Wildcat Pass |
|
|
| | |
|
|
| | - Intel Wolf Pass |
|
|
+--------------------------------------------------------------------------------+----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
|
|
| Disk Controllers | - Dell |
|
|
| | |
|
|
| | |
|
|
| | - PERC H310 Mini |
|
|
| | |
|
|
| | - PERC H730 Mini |
|
|
| | |
|
|
| | - PERC H740P |
|
|
| | |
|
|
| | - PERC H330 |
|
|
| | |
|
|
| | - PERC HBA330 |
|
|
| | |
|
|
| | |
|
|
| | |
|
|
| | - HPE Smart Array |
|
|
| | |
|
|
| | |
|
|
| | - P440ar |
|
|
| | |
|
|
| | - P420i |
|
|
| | |
|
|
| | - P408i-a |
|
|
| | |
|
|
| | - P816i-a |
|
|
| | |
|
|
| | |
|
|
| | - LSI 2308 |
|
|
| | |
|
|
| | - LSI 3008 |
|
|
+--------------------------------------------------------------------------------+----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
|
|
| NICs Verified for PXE Boot, Management, and OAM Networks | - Intel I210 \(Springville\) 1G |
|
|
| | |
|
|
| | - Intel I350 \(Powerville\) 1G |
|
|
| | |
|
|
| | - Intel 82599 \(Niantic\) 10G |
|
|
| | |
|
|
| | - Intel X540 10G |
|
|
| | |
|
|
| | - Intel X710/XL710 \(Fortville\) 10G |
|
|
| | |
|
|
| | - Intel X722 \(Fortville\) 10G |
|
|
| | |
|
|
| | - Intel E810 25G Columbiaville \(Salem Channel\) NIC \(for management and OAM networks only\) |
|
|
| | |
|
|
| | - Emulex XE102 10G |
|
|
| | |
|
|
| | - Broadcom BCM5719 1G |
|
|
| | |
|
|
| | - Broadcom BCM57810 10G |
|
|
| | |
|
|
| | - Mellanox MT27710 Family \(ConnectX-4 Lx\) 10G/25G |
|
|
| | |
|
|
| | - Mellanox MT27700 Family \(ConnectX-4\) 40G |
|
|
+--------------------------------------------------------------------------------+----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
|
|
| NICs Verified for Data Interfaces [#]_ | The following NICs are supported: |
|
|
| | |
|
|
| | - Intel I350 \(Powerville\) 1G |
|
|
| | |
|
|
| | - Intel 82599 \(Niantic\) 10G |
|
|
| | |
|
|
| | - Intel X710/XL710 \(Fortville\) 10 G |
|
|
| | |
|
|
| | - Intel X552 \(Xeon-D\) 10G |
|
|
| | |
|
|
| | - Mellanox Technologies |
|
|
| | |
|
|
| | |
|
|
| | - MT27710 Family \(ConnectX-4\) 10G/25G |
|
|
| | |
|
|
| | - MT27700 Family \(ConnectX-4\) 40G |
|
|
| | |
|
|
+--------------------------------------------------------------------------------+----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
|
|
| PCI-Passthrough or PCI SR-IOV NICs | - Intel E810 25G Columbiaville \(Salem Channel\) NIC \(SR-IOV only\) |
|
|
| | |
|
|
| | - Intel 82599 \(Niantic\) 10 G |
|
|
| | |
|
|
| | - Intel X710/XL710 \(Fortville\) 10G |
|
|
| | |
|
|
| | - Mellanox Technologies |
|
|
| | |
|
|
| | |
|
|
| | - MT27710 Family \(ConnectX-4\) 10G/25G |
|
|
| | |
|
|
| | - MT27700 Family \(ConnectX-4\) 40G |
|
|
| | |
|
|
| | |
|
|
| | .. note:: |
|
|
| | For a Mellanox using PCI passthrough or a CX4 using PCI passthrough or SR-IOV, SR-IOV must be enabled in the CX4 firmware. For more information, see, `HowTo Configure SR-IOV for ConnectX-4/ConnectX-5/ConnectX-6 with KVM (Ethernet) <https://community.mellanox.com/s/article/HowTo-Configure-SR-IOV-for-ConnectX-4-ConnectX-5-ConnectX-6-with-KVM-Ethernet#jive_content_id_I_Enable_SRIOV_on_the_Firmware>`__. |
|
|
| | |
|
|
| | |
|
|
| | .. note:: |
|
|
| | The maximum number of VFs per hosted application instance, across all PCI devices, is 32. |
|
|
| | |
|
|
| | For example, a hardware encryption hosted application can be launched with virtio interfaces and 32 QAT VFs. However, a hardware encryption hosted application with an SR-IOV network interface \(with 1 VF\) can only be launched with 31 VFs. |
|
|
| | |
|
|
| | .. note:: |
|
|
| | Dual-use configuration \(PCI passthrough or PCI SR-IOV on the same interface\) is supported for Fortville NICs only. |
|
|
+--------------------------------------------------------------------------------+----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
|
|
| PCI SR-IOV Hardware Accelerators | - Intel AV-ICE02 VPN Acceleration Card, based on the Intel Coleto Creek 8925/8950, and C62x device with QuickAssist ®. |
|
|
+--------------------------------------------------------------------------------+----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
|
|
| Hardware Accelerator Devices Verified for PCI-Passthrough or PCI SR-IOV Access | - ACC100 Adapter \(Mount Bryce\) - SRIOV only |
|
|
+--------------------------------------------------------------------------------+----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
|
|
| GPUs Verified for PCI Passthrough | - NVIDIA Corporation: VGA compatible controller - GM204GL \(Tesla M60 rev a1\) |
|
|
| | |
|
|
| | - NVIDIA T4 TENSOR CORE GPU |
|
|
| | |
|
|
| | |
|
|
+--------------------------------------------------------------------------------+----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
|
|
| Board Management Controllers | - HPE iLO3 |
|
|
| | |
|
|
| | - HPE iLO4 |
|
|
| | |
|
|
| | - Quanta |
|
|
+--------------------------------------------------------------------------------+----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------+
|
|
|
|
.. include:: ../../_includes/release-notes-overview-footnote.rest |