100 Series Alarm Messages
The system inventory and maintenance service reports system changes with different degrees of severity. Use the reported alarms to monitor the overall health of the system.
Alarm ID: 100.101 |
Platform CPU threshold exceeded; threshold x%, actual y%. CRITICAL @ 95% MAJOR @ 90% |
Entity Instance | host=<hostname> |
Degrade Affecting Severity: | Critical |
Severity: | C/M* |
Proposed Repair Action | Monitor and if condition persists, contact next level of support. |
Alarm ID: 100.103 |
Memory threshold exceeded; threshold x%, actual y% . CRITICAL @ 90% MAJOR @ 80% |
Entity Instance | host=<hostname> |
Degrade Affecting Severity: | Critical |
Severity: | C/M |
Proposed Repair Action | Monitor and if condition persists, contact next level of support; may require additional memory on Host. |
Alarm ID: 100.104 |
File System threshold exceeded; threshold x%, actual y% CRITICAL @ 90% MAJOR @ 80% |
Entity Instance | host=<hostname>.filesystem=<mount-dir> |
Degrade Affecting Severity: | Critical |
Severity: | C*/M |
Proposed Repair Action | Monitor and if condition persists, consider adding additional physical volumes to the volume group. |
Alarm ID: 100.105 | <fs_name> filesystem is not added on both controllers and/or does not have the same size: <hostname>. |
Entity Instance | fs_name=<image-conversion> |
Degrade Affecting Severity: | None |
Severity: | C/M* |
Proposed Repair Action |
Add image-conversion filesystem on both controllers. Consult the System Administration Manual for more details. If problem persists, contact next level of support. |
Alarm ID: 100.106 | 'OAM' Port failed. |
Entity Instance | host=<hostname>.port=<port-name> |
Degrade Affecting Severity: | Major |
Severity: | M* |
Proposed Repair Action | Check cabling and far-end port configuration and status on adjacent equipment. |
Alarm ID: 100.107 |
'OAM' Interface degraded. or 'OAM' Interface failed. |
Entity Instance | host=<hostname>.interface=<if-name> |
Degrade Affecting Severity: | Major |
Severity: | C or M* |
Proposed Repair Action | Check cabling and far-end port configuration and status on adjacent equipment. |
Alarm ID: 100.108 | 'MGMT' Port failed. |
Entity Instance | host=<hostname>.port=<port-name> |
Degrade Affecting Severity: | Major |
Severity: | M* |
Proposed Repair Action | Check cabling and far-end port configuration and status on adjacent equipment. |
Alarm ID: 100.109 |
'OAM' Interface degraded. or 'OAM' Interface failed. |
Entity Instance | host=<hostname>.interface=<if-name> |
Degrade Affecting Severity: | Major |
Severity: | C or M* |
Proposed Repair Action | Check cabling and far-end port configuration and status on adjacent equipment. |
Alarm ID: 100.110 | 'CLUSTER-HOST' Port failed. |
Entity Instance | host=<hostname>.port=<port-name> |
Degrade Affecting Severity: | Major |
Severity: | C or M* |
Proposed Repair Action | Check cabling and far-end port configuration and status on adjacent equipment. |
Alarm ID: 100.111 |
'CLUSTER-HOST' Interface degraded. OR 'CLUSTER-HOST' Interface failed. |
Entity Instance | host=<hostname>.interface=<if-name> |
Degrade Affecting Severity: | Major |
Severity: | C or M* |
Proposed Repair Action | Check cabling and far-end port configuration and status on adjacent equipment. |
Alarm ID: 100.112 | 'DATA-VRS' Port down. |
Entity Instance | host=<hostname>.port=<port-name> |
Degrade Affecting Severity: | Major |
Severity: | M |
Proposed Repair Action | Check cabling and far-end port configuration and status on adjacent equipment. |
Alarm ID: 100.113 |
'DATA-VRS' Interface degraded. or 'DATA-VRS' Interface down. |
Entity Instance | host=<hostname>.interface=<if-name> |
Degrade Affecting Severity: | Major |
Severity: | C or M* |
Proposed Repair Action | Check cabling and far-end port configuration and status on adjacent equipment. |
Alarm ID: 100.114 |
NTP configuration does not contain any valid or reachable NTP servers. The alarm is raised regardless of NTP enabled/disabled status. NTP address <IP address> is not a valid or a reachable NTP server. Connectivity to external PTP Clock Synchronization is lost. |
Entity Instance |
host=<hostname>.ntp host=<hostname>.ntp=<IP address> |
Degrade Affecting Severity: | None |
Severity: | M or m |
Proposed Repair Action | Monitor and if condition persists, contact next level of support. |
Alarm ID: 100.118 | Controller cannot establish connection with remote logging server. |
Entity Instance | host=<hostname> |
Degrade Affecting Severity: | None |
Severity: | m |
Proposed Repair Action | Ensure Remote Log Server IP is reachable from Controller through OAM interface; otherwise contact next level of support. |
Alarm ID: 100.119 |
Major: PTP configuration or out-of-tolerance time-stamping conditions. Minor: PTP out-of-tolerance time-stamping condition. |
Entity Instance |
host=<hostname>.ptp OR host=<hostname>.ptp=no-lock OR host=<hostname>.ptp=<interface>.unsupported=hardware-timestamping OR host=<hostname>.ptp=<interface>.unsupported=software-timestamping OR host=<hostname>.ptp=<interface>.unsupported=legacy-timestamping OR host=<hostname>.ptp=out-of-tolerance |
Degrade Affecting Severity: | None |
Severity: | M or m |
Proposed Repair Action | Monitor and, if condition persists, contact next level of support. |