.. _telemetry-alarms:
|
|
|
|
======
|
|
Alarms
|
|
======
|
|
|
|
Alarms provide user-oriented Monitoring-as-a-Service for resources
|
|
running on OpenStack. This type of monitoring ensures you can
|
|
automatically scale in or out a group of instances through the
|
|
Orchestration service, but you can also use alarms for general-purpose
|
|
awareness of your cloud resources' health.
|
|
|
|
These alarms follow a tri-state model:
|
|
|
|
ok
|
|
The rule governing the alarm has been evaluated as ``False``.
|
|
|
|
alarm
|
|
The rule governing the alarm has been evaluated as ``True``.
|
|
|
|
insufficient data
|
|
There are not enough datapoints available in the evaluation periods
|
|
to meaningfully determine the alarm state.
|
|
|
|
Alarm definitions
|
|
~~~~~~~~~~~~~~~~~
|
|
|
|
The definition of an alarm provides the rules that govern when a state
|
|
transition should occur, and the actions to be taken thereon. The
|
|
nature of these rules depend on the alarm type.
|
|
|
|
Threshold rule alarms
|
|
---------------------
|
|
|
|
For conventional threshold-oriented alarms, state transitions are
|
|
governed by:
|
|
|
|
* A static threshold value with a comparison operator such as greater
|
|
than or less than.
|
|
|
|
* A statistic selection to aggregate the data.
|
|
|
|
* A sliding time window to indicate how far back into the recent past
|
|
you want to look.
|
|
|
|
Both Ceilometer and Gnocchi are supported as data source of the threshold rule
|
|
alarm. Valid threshold alarms are:
|
|
|
|
* threshold
|
|
* gnocchi_resources_threshold
|
|
* gnocchi_aggregation_by_metrics_threshold
|
|
* gnocchi_aggregation_by_resources_threshold
|
|
|
|
Composite rule alarms
|
|
---------------------
|
|
|
|
Composite alarms enable users to define an alarm with multiple triggering
|
|
conditions, using a combination of ``and`` and ``or`` relations.
|
|
|
|
Alarm dimensioning
|
|
~~~~~~~~~~~~~~~~~~
|
|
|
|
A key associated concept is the notion of *dimensioning* which
|
|
defines the set of matching meters that feed into an alarm
|
|
evaluation. Recall that meters are per-resource-instance, so in the
|
|
simplest case an alarm might be defined over a particular meter
|
|
applied to all resources visible to a particular user. More useful
|
|
however would be the option to explicitly select which specific
|
|
resources you are interested in alarming on.
|
|
|
|
At one extreme you might have narrowly dimensioned alarms where this
|
|
selection would have only a single target (identified by resource
|
|
ID). At the other extreme, you could have widely dimensioned alarms
|
|
where this selection identifies many resources over which the
|
|
statistic is aggregated. For example all instances booted from a
|
|
particular image or all instances with matching user metadata (the
|
|
latter is how the Orchestration service identifies autoscaling
|
|
groups).
|
|
|
|
Alarm evaluation
|
|
~~~~~~~~~~~~~~~~
|
|
|
|
Alarms are evaluated by the ``alarm-evaluator`` service on a periodic
|
|
basis, defaulting to once every minute.
|
|
|
|
Alarm actions
|
|
-------------
|
|
|
|
Any state transition of individual alarm (to ``ok``, ``alarm``, or
|
|
``insufficient data``) may have one or more actions associated with
|
|
it. These actions effectively send a signal to a consumer that the
|
|
state transition has occurred, and provide some additional context.
|
|
This includes the new and previous states, with some reason data
|
|
describing the disposition with respect to the threshold, the number
|
|
of datapoints involved and most recent of these. State transitions
|
|
are detected by the ``alarm-evaluator``, whereas the
|
|
``alarm-notifier`` effects the actual notification action.
|
|
|
|
HTTP/HTTPS action
|
|
These are the *de facto* notification type used by Telemetry alarming and
|
|
simply involve an HTTP(S) POST request being sent to an endpoint, with a
|
|
request body containing a description of the state transition encoded as a
|
|
JSON fragment.
|
|
|
|
OpenStack Services
|
|
The user is able to define an alarm that simply trigger some OpenStack
|
|
service by directly specifying the service URL, e.g.
|
|
``trust+http://127.0.0.1:7070/v1/webhooks/ab91ef39-3e4a-4750-a8b8-0271518cd481/invoke``.
|
|
``aodh-notifier`` will prepare ``X-Auth-Token`` header and send HTTP(S) POST
|
|
request to that URL, containing the alarm information in the request body.
|
|
|
|
Heat Autoscaling
|
|
This notifier works together with ``loadbalancer_member_health`` evaluator.
|
|
Presumably, the end user defines a Heat template which contains an
|
|
autoscaling group and all the members in the group are joined in an Octavia
|
|
load balancer in order to expose highly available service to the outside, so
|
|
that when the stack scales up or scales down, Heat makes sure the new members
|
|
are joining the load balancer automatically and the old members are removed.
|
|
However, this notifier deals with the situation that when some member fails,
|
|
the Heat stack could be recovered automatically. More information
|
|
`here <https://docs.openstack.org/self-healing-sig/latest/use-cases/loadbalancer-member.html>`_
|
|
|
|
Log actions
|
|
These are a lightweight alternative to webhooks, whereby the state transition
|
|
is simply logged by the ``alarm-notifier``, and are intended primarily for
|
|
testing purposes by admin users.
|
|
|
|
If none of the above actions satisfy your requirement, you can implement your
|
|
own alarm actions according to the current suppported actions in
|
|
``aodh/notifier`` folder.
|
|
|
|
|
|
Using alarms
|
|
~~~~~~~~~~~~
|
|
|
|
Alarm creation
|
|
--------------
|
|
|
|
Threshold based alarm
|
|
`````````````````````
|
|
|
|
An example of creating a Gnocchi threshold-oriented alarm, based on an upper
|
|
bound on the CPU utilization for a particular instance:
|
|
|
|
.. code-block:: console
|
|
|
|
$ aodh alarm create \
|
|
--name cpu_hi \
|
|
--type gnocchi_resources_threshold \
|
|
--description 'instance running hot' \
|
|
--metric cpu_util \
|
|
--threshold 70.0 \
|
|
--comparison-operator gt \
|
|
--aggregation-method mean \
|
|
--granularity 600 \
|
|
--evaluation-periods 3 \
|
|
--alarm-action 'log://' \
|
|
--resource-id INSTANCE_ID \
|
|
--resource-type instance
|
|
|
|
This creates an alarm that will fire when the average CPU utilization
|
|
for an individual instance exceeds 70% for three consecutive 10
|
|
minute periods. The notification in this case is simply a log message,
|
|
though it could alternatively be a webhook URL.
|
|
|
|
.. note::
|
|
|
|
Alarm names must be unique for the alarms associated with an
|
|
individual project. Administrator can limit the maximum
|
|
resulting actions for three different states, and the
|
|
ability for a normal user to create ``log://`` and ``test://``
|
|
notifiers is disabled. This prevents unintentional
|
|
consumption of disk and memory resources by the
|
|
Telemetry service.
|
|
|
|
The sliding time window over which the alarm is evaluated is 30
|
|
minutes in this example. This window is not clamped to wall-clock
|
|
time boundaries, rather it's anchored on the current time for each
|
|
evaluation cycle, and continually creeps forward as each evaluation
|
|
cycle rolls around (by default, this occurs every minute).
|
|
|
|
.. note::
|
|
|
|
The alarm granularity must match the granularities of the metric configured
|
|
in Gnocchi.
|
|
|
|
Otherwise the alarm will tend to flit in and out of the
|
|
``insufficient data`` state due to the mismatch between the actual
|
|
frequency of datapoints in the metering store and the statistics
|
|
queries used to compare against the alarm threshold. If a shorter
|
|
alarm period is needed, then the corresponding interval should be
|
|
adjusted in the ``pipeline.yaml`` file.
|
|
|
|
Other notable alarm attributes that may be set on creation, or via a
|
|
subsequent update, include:
|
|
|
|
state
|
|
The initial alarm state (defaults to ``insufficient data``).
|
|
|
|
description
|
|
A free-text description of the alarm (defaults to a synopsis of the
|
|
alarm rule).
|
|
|
|
enabled
|
|
True if evaluation and actioning is to be enabled for this alarm
|
|
(defaults to ``True``).
|
|
|
|
repeat-actions
|
|
True if actions should be repeatedly notified while the alarm
|
|
remains in the target state (defaults to ``False``).
|
|
|
|
ok-action
|
|
An action to invoke when the alarm state transitions to ``ok``.
|
|
|
|
insufficient-data-action
|
|
An action to invoke when the alarm state transitions to
|
|
``insufficient data``.
|
|
|
|
time-constraint
|
|
Used to restrict evaluation of the alarm to certain times of the
|
|
day or days of the week (expressed as ``cron`` expression with an
|
|
optional timezone).
|
|
|
|
Composite alarm
|
|
```````````````
|
|
|
|
An example of creating a composite alarm, based on the composite of
|
|
two basic rules:
|
|
|
|
.. code-block:: console
|
|
|
|
$ aodh alarm create \
|
|
--name meta \
|
|
--type composite \
|
|
--composite-rule '{"or": [{"threshold": 0.8, "metric": "cpu_util", \
|
|
"type": "gnocchi_resources_threshold", "resource_id": INSTANCE_ID1, \
|
|
"resource_type": "instance", "aggregation_method": "last"}, \
|
|
{"threshold": 0.8, "metric": "cpu_util", \
|
|
"type": "gnocchi_resources_threshold", "resource_id": INSTANCE_ID2, \
|
|
"resource_type": "instance", "aggregation_method": "last"}]}' \
|
|
--alarm-action 'http://example.org/notify'
|
|
|
|
This creates an alarm that will fire when either of two basic rules
|
|
meets the condition. The notification in this case is a webhook call.
|
|
Any number of basic rules can be composed into a composite rule this
|
|
way, using either ``and`` or ``or``. Additionally, composite rules
|
|
can contain nested conditions:
|
|
|
|
.. note::
|
|
|
|
Observe the *underscore in* ``resource_id`` & ``resource_type`` in
|
|
composite rule as opposed to ``--resource-id`` &
|
|
``--resource-type`` CLI arguments.
|
|
|
|
.. code-block:: console
|
|
|
|
$ aodh alarm create \
|
|
--name meta \
|
|
--type composite \
|
|
--composite-rule '{"or": [ALARM_1, {"and": [ALARM_2, ALARM_3]}]}' \
|
|
--alarm-action 'http://example.org/notify'
|
|
|
|
|
|
Event based alarm
|
|
`````````````````
|
|
|
|
An example of creating a event alarm based on power state of
|
|
instance:
|
|
|
|
.. code-block:: console
|
|
|
|
$ aodh alarm create \
|
|
--type event \
|
|
--name instance_off \
|
|
--description 'Instance powered OFF' \
|
|
--event-type "compute.instance.power_off.*" \
|
|
--enable True \
|
|
--query "traits.instance_id=string::INSTANCE_ID" \
|
|
--alarm-action 'log://' \
|
|
--ok-action 'log://' \
|
|
--insufficient-data-action 'log://'
|
|
|
|
Valid list of ``event-type`` and ``traits`` can be found in
|
|
``event_definitions.yaml`` file . ``--query`` may also contain mix of
|
|
traits for example to create alarm when instance is powered on but
|
|
went into error state:
|
|
|
|
.. code-block:: console
|
|
|
|
$ aodh alarm create \
|
|
--type event \
|
|
--name instance_on_but_in_err_state \
|
|
--description 'Instance powered ON but in error state' \
|
|
--event-type "compute.instance.power_on.*" \
|
|
--enable True \
|
|
--query "traits.instance_id=string::INSTANCE_ID;traits.state=string::error" \
|
|
--alarm-action 'log://' \
|
|
--ok-action 'log://' \
|
|
--insufficient-data-action 'log://'
|
|
|
|
Sample output of alarm type **event**:
|
|
|
|
.. code-block:: console
|
|
|
|
+---------------------------+---------------------------------------------------------------+
|
|
| Field | Value |
|
|
+---------------------------+---------------------------------------------------------------+
|
|
| alarm_actions | ['log://'] |
|
|
| alarm_id | 15c0da26-524d-40ad-8fba-3e55ee0ddc91 |
|
|
| description | Instance powered ON but in error state |
|
|
| enabled | True |
|
|
| event_type | compute.instance.power_on.* |
|
|
| insufficient_data_actions | ['log://'] |
|
|
| name | instance_on_state_err |
|
|
| ok_actions | ['log://'] |
|
|
| project_id | 9ee200732f4c4d10a6530bac746f1b6e |
|
|
| query | traits.instance_id = bb912729-fa51-443b-bac6-bf4c795f081d AND |
|
|
| | traits.state = error |
|
|
| repeat_actions | False |
|
|
| severity | low |
|
|
| state | insufficient data |
|
|
| state_timestamp | 2017-07-15T02:28:31.114455 |
|
|
| time_constraints | [] |
|
|
| timestamp | 2017-07-15T02:28:31.114455 |
|
|
| type | event |
|
|
| user_id | 89b4e48bcbdb4816add7800502bd5122 |
|
|
+---------------------------+---------------------------------------------------------------+
|
|
|
|
.. note::
|
|
|
|
To enable event alarms please refer `Configuration
|
|
<https://docs.openstack.org/aodh/latest/contributor/event-alarm.html#configuration>`_
|
|
|
|
Alarm retrieval
|
|
---------------
|
|
|
|
You can display all your alarms via (some attributes are omitted for
|
|
brevity):
|
|
|
|
.. code-block:: console
|
|
|
|
$ aodh alarm list
|
|
+----------+-----------+--------+-------------------+----------+---------+
|
|
| alarm_id | type | name | state | severity | enabled |
|
|
+----------+-----------+--------+-------------------+----------+---------+
|
|
| ALARM_ID | threshold | cpu_hi | insufficient data | low | True |
|
|
+----------+-----------+--------+-------------------+----------+---------+
|
|
|
|
In this case, the state is reported as ``insufficient data`` which
|
|
could indicate that:
|
|
|
|
* meters have not yet been gathered about this instance over the
|
|
evaluation window into the recent past (for example a brand-new
|
|
instance)
|
|
|
|
* *or*, that the identified instance is not visible to the
|
|
user/project owning the alarm
|
|
|
|
* *or*, simply that an alarm evaluation cycle hasn't kicked off since
|
|
the alarm was created (by default, alarms are evaluated once per
|
|
minute).
|
|
|
|
.. note::
|
|
|
|
The visibility of alarms depends on the role and project
|
|
associated with the user issuing the query:
|
|
|
|
* admin users see *all* alarms, regardless of the owner
|
|
|
|
* non-admin users see only the alarms associated with their project
|
|
(as per the normal project segregation in OpenStack)
|
|
|
|
Alarm update
|
|
------------
|
|
|
|
Once the state of the alarm has settled down, we might decide that we
|
|
set that bar too low with 70%, in which case the threshold (or most
|
|
any other alarm attribute) can be updated thusly:
|
|
|
|
.. code-block:: console
|
|
|
|
$ aodh alarm update ALARM_ID --threshold 75
|
|
|
|
The change will take effect from the next evaluation cycle, which by
|
|
default occurs every minute.
|
|
|
|
Most alarm attributes can be changed in this way, but there is also
|
|
a convenient short-cut for getting and setting the alarm state:
|
|
|
|
.. code-block:: console
|
|
|
|
$ openstack alarm state get ALARM_ID
|
|
$ openstack alarm state set --state ok ALARM_ID
|
|
|
|
Over time the state of the alarm may change often, especially if the
|
|
threshold is chosen to be close to the trending value of the
|
|
statistic. You can follow the history of an alarm over its lifecycle
|
|
via the audit API:
|
|
|
|
.. code-block:: console
|
|
|
|
$ aodh alarm-history show ALARM_ID
|
|
+-----------+------------------+---------------------------------------------------+----------+
|
|
| timestamp | type | detail | event_id |
|
|
+-----------+------------------+---------------------------------------------------+----------+
|
|
| TIME_3 | rule change | {"rule": {"evaluation_periods": 3, "metric": | EVENT_ID |
|
|
| | | "cpu_util", "resource_id": RESOURCE_ID, | |
|
|
| | | "aggregation_method": "mean", "granularity":600, | |
|
|
| | | "threshold": 75.0, "comparison_operator": "gt" | |
|
|
| | | "resource_type": "instance"}} | |
|
|
| TIME_2 | state transition | {"transition_reason": "Transition to alarm due 3 | EVENT_ID |
|
|
| | | samples outside threshold, most recent: | |
|
|
| | | 81.4108514719", "state": "alarm"} | |
|
|
| TIME_1 | state transition | {"transition_reason": "Transition to ok due to 1 | EVENT_ID |
|
|
| | | samples inside threshold, most recent: | |
|
|
| | | 67.952938019089", "state": "ok"} | |
|
|
| TIME_0 | creation | {"alarm_actions": ["log://"], "user_id": USER_ID, | EVENT_ID |
|
|
| | | "name": "cup_hi", "state": "insufficient data", | |
|
|
| | | "timestamp": TIME_0, "description": "instance | |
|
|
| | | running hot", "enabled": true, "state_timestamp": | |
|
|
| | | TIME_0, "rule": {"evaluation_periods": 3, | |
|
|
| | | "metric": "cpu_util", "resource_id": RESOURCE_ID, | |
|
|
| | | "aggregation_method": "mean", "granularity": 600, | |
|
|
| | | "resource_type": "instance"}, "alarm_id": | |
|
|
| | | ALARM_ID, "time_constraints": [], | |
|
|
| | | "insufficient_data_actions": [], | |
|
|
| | | "repeat_actions": false, "ok_actions": [], | |
|
|
| | | "project_id": PROJECT_ID, "type": | |
|
|
| | | "gnocchi_resources_threshold", "severity": "low"} | |
|
|
+-----------+------------------+---------------------------------------------------+----------+
|
|
|
|
Alarm deletion
|
|
--------------
|
|
|
|
An alarm that is no longer required can be disabled so that it is no
|
|
longer actively evaluated:
|
|
|
|
.. code-block:: console
|
|
|
|
$ aodh alarm update --enabled False ALARM_ID
|
|
|
|
or even deleted permanently (an irreversible step):
|
|
|
|
.. code-block:: console
|
|
|
|
$ aodh alarm delete ALARM_ID
|
|
|
|
Debug alarms
|
|
------------
|
|
|
|
A good place to start is to add ``--debug`` flag when creating or
|
|
updating an alarm. For example:
|
|
|
|
.. code-block:: console
|
|
|
|
$ aodh --debug alarm create <OTHER_PARAMS>
|
|
|
|
Look for the state to transition when event is triggered in
|
|
``/var/log/aodh/listener.log`` file. For example, the below logs shows
|
|
the transition state of alarm with id
|
|
``85a2942f-a2ec-4310-baea-d58f9db98654`` triggered by event id
|
|
``abe437a3-b75b-40b4-a3cb-26022a919f5e``
|
|
|
|
.. code-block:: console
|
|
|
|
2017-07-15 07:03:20.149 2866 INFO aodh.evaluator [-] alarm 85a2942f-a2ec-4310-baea-d58f9db98654 transitioning to alarm because Event <id=abe437a3-b75b-40b4-a3cb-26022a919f5e,event_type=compute.instance.power_off.start> hits the query <query=[{"field": "traits.instance_id", "op": "eq", "type": "string", "value": "bb912729-fa51-443b-bac6-bf4c795f081d"}]>.
|
|
|
|
|
|
The below entry in ``/var/log/aodh/notifier.log`` also confirms that
|
|
event id ``abe437a3-b75b-40b4-a3cb-26022a919f5e`` hits the query
|
|
matching instance id ``bb912729-fa51-443b-bac6-bf4c795f081d``
|
|
|
|
.. code-block:: console
|
|
|
|
2017-07-15 07:03:24.071 2863 INFO aodh.notifier.log [-] Notifying alarm instance_off 85a2942f-a2ec-4310-baea-d58f9db98654 of low priority from insufficient data to alarm with action log: because Event <id=abe437a3-b75b-40b4-a3cb-26022a919f5e,event_type=compute.instance.power_off.start> hits the query <query=[{"field": "traits.instance_id", "op": "eq", "type": "string", "value": "bb912729-fa51-443b-bac6-bf4c795f081d"}]>
|
|
|
|
|
|
``aodh alarm-history`` as mentioned earlier will also display the
|
|
transition:
|
|
|
|
.. code-block:: console
|
|
|
|
$ aodh alarm-history show 85a2942f-a2ec-4310-baea-d58f9db98654
|
|
+----------------------------+------------------+--------------------------------------------------------------------------------------------------------------------------+--------------------------------------+
|
|
| timestamp | type | detail | event_id |
|
|
+----------------------------+------------------+--------------------------------------------------------------------------------------------------------------------------+--------------------------------------+
|
|
| 2017-07-15T01:33:20.390623 | state transition | {"transition_reason": "Event <id=abe437a3-b75b-40b4-a3cb-26022a919f5e,event_type=compute.instance.power_off.start> hits | c5ca92ae-584b-4da6-a12c-b7a00dd39fef |
|
|
| | | the query <query=[{\"field\": \"traits.instance_id\", \"op\": \"eq\", \"type\": \"string\", \"value\": \"bb912729-fa51 | |
|
|
| | | -443b-bac6-bf4c795f081d\"}]>.", "state": "alarm"} | |
|
|
| 2017-07-15T01:31:14.516188 | creation | {"alarm_actions": ["log://"], "user_id": "89b4e48bcbdb4816add7800502bd5122", "name": "instance_off", "state": | fb31f4c2-e357-44c3-9b6a-bd2aaaa4ae68 |
|
|
| | | "insufficient data", "timestamp": "2017-07-15T01:31:14.516188", "description": "event_instance_power_off", "enabled": | |
|
|
| | | true, "state_timestamp": "2017-07-15T01:31:14.516188", "rule": {"query": [{"field": "traits.instance_id", "type": | |
|
|
| | | "string", "value": "bb912729-fa51-443b-bac6-bf4c795f081d", "op": "eq"}], "event_type": "compute.instance.power_off.*"}, | |
|
|
| | | "alarm_id": "85a2942f-a2ec-4310-baea-d58f9db98654", "time_constraints": [], "insufficient_data_actions": ["log://"], | |
|
|
| | | "repeat_actions": false, "ok_actions": ["log://"], "project_id": "9ee200732f4c4d10a6530bac746f1b6e", "type": "event", | |
|
|
| | | "severity": "low"} | |
|
|
+----------------------------+------------------+--------------------------------------------------------------------------------------------------------------------------+--------------------------------------+
|