Add power state change callbacks of an instance to nova by performing API requests. Whenever there is a change in the power state of a physical instance (example a "power on" or "power off" IPMI command is issued or the periodic ``_sync_power_states`` task detects a change in power state) ironic will create and send a ``power-update`` external event to nova using which nova will update the power state of the instance in its database. By conveying the power state changes to nova, ironic becomes the source of truth thus preventing nova from forcing wrong power states on the instance during the nova-ironic periodic sync. It also adds the possibility of bringing up/down a physical instance through the ironic API even if it was put down/up through the nova API. Note that ironic only sends requests to nova if the target power state is either "power on" or "power off". Other error states will be ignored. In cases where the power state change is originally coming from nova, the event will still be created and sent to nova and on the nova side it will be a no-op with a debug log saying the node is already powering on/off. NOTE: Although an exclusive lock (task_manager.upgrade_lock() method) is used when calling the nova API to send events, there can still be a race condition if the nova-ironic power sync happens to happen a nano-second before the power state change event is received from ironic in which case the nova state will be forced on the node. Credit for introducing ksa adapter: Eric Fried <openstack@fried.cc> Depends-On: https://review.opendev.org/#/c/645611/ Part of blueprint nova-support-instance-power-update Story: 2004969 Task: 29424 Change-Id: I6d105524e1645d9a40dfeae2850c33cf2d110826
76 lines
4.1 KiB
ReStructuredText
76 lines
4.1 KiB
ReStructuredText
===================================
|
|
Power Sync with the Compute Service
|
|
===================================
|
|
|
|
Baremetal Power Sync
|
|
====================
|
|
Each Baremetal conductor process runs a periodic task which synchronizes the
|
|
power state of the nodes between its database and the actual hardware. If the
|
|
value of the :oslo.config:option:`conductor.force_power_state_during_sync`
|
|
option is set to ``true`` the power state in the database will be forced on
|
|
the hardware and if it is set to ``false`` the hardware state will be forced
|
|
on the database. If this periodic task is enabled, it runs at an interval
|
|
defined by the :oslo.config:option:`conductor.sync_power_state_interval` config
|
|
option for those nodes which are not in maintenance.
|
|
|
|
Compute-Baremetal Power Sync
|
|
============================
|
|
Each ``nova-compute`` process in the Compute service runs a periodic task which
|
|
synchronizes the power state of servers between its database and the compute
|
|
driver. If enabled, it runs at an interval defined by the
|
|
`sync_power_state_interval` config option on the ``nova-compute`` process.
|
|
In case of the compute driver being baremetal driver, this sync will happen
|
|
between the databases of the compute and baremetal services. Since the sync
|
|
happens on the ``nova-compute`` process, the state in the compute database
|
|
will be forced on the baremetal database in case of inconsistencies. Hence a
|
|
node which was put down using the compute service API cannot be brought up
|
|
through the baremetal service API since the power sync task will regard the
|
|
compute service's knowledge of the power state as the source of truth. In order
|
|
to get around this disadvantage of the compute-baremetal power sync,
|
|
baremetal service does power state change callbacks to the compute service
|
|
using external events.
|
|
|
|
Power State Change Callbacks to the Compute Service
|
|
---------------------------------------------------
|
|
|
|
Whenever the Baremetal service changes the power state of a node, it can issue
|
|
a notification to the Compute service. The Compute service will consume this
|
|
notification and update the power state of the instance in its database.
|
|
By conveying all the power state changes to the compute service, the baremetal
|
|
service becomes the source of truth thus preventing the compute service from
|
|
forcing wrong power states on the physical instance during the
|
|
compute-baremetal power sync. It also adds the possibility of bringing
|
|
up/down a physical instance through the baremetal service API even if it was
|
|
put down/up through the compute service API.
|
|
|
|
This change requires the :oslo.config:group:`nova` section and the necessary
|
|
authentication options like the :oslo.config:option:`nova.auth_url` to be
|
|
defined in the configuration file of the baremetal service. If it is not
|
|
configured the baremetal service will not be able to send notifications to the
|
|
compute service and it will fall back to the behaviour of the compute service
|
|
forcing power states on the baremetal service during the power sync.
|
|
See :oslo.config:group:`nova` group for more details on the available config
|
|
options.
|
|
|
|
In case of baremetal stand alone deployments where there is no compute service
|
|
running, the :oslo.config:option:`nova.send_power_notifications` config option
|
|
should be set to ``False`` to disable power state change callbacks to the
|
|
compute service.
|
|
|
|
.. note::
|
|
The baremetal service sends notifications to the compute service only if
|
|
the target power state is ``power on`` or ``power off``. Other error
|
|
and ``None`` states will be ignored. In situations where the power state
|
|
change is originally coming from the compute service, the notification
|
|
will still be sent by the baremetal service and it will be a no-op on the
|
|
compute service side with a debug log stating the node is already powering
|
|
on/off.
|
|
|
|
.. note::
|
|
Although an exclusive lock is used when sending notifications to the
|
|
compute service, there can still be a race condition if the
|
|
compute-baremetal power sync happens to happen a nano-second before the
|
|
power state change event is received from the baremetal service in which
|
|
case the power state from compute service's database will be forced on the
|
|
node.
|